/Content/Upload/Product/Human_ELISA_kits_Diagnocine_1200_1200(38).jpg

Human Interleukin 12,IL-12/P70 ELISA KIT

Product#: CS-CSB-E04599h
$627.84
Availability:
Ships in 24 hours

The Ultimate 1-Stop ELISA Marketplace:

60,000+ ELISA kits Available to Serve Scientists from All Fields of Life Science

Always Powered by Diagnocine for Precision Research.

 
Made In-USA · ISO 13485 Certified 

Most comprehensive buffers, reagents and detection agents are provided with each kit to optimize data output.  
All-inclusive format covers everything from sample preparation to signal detection.  Every step can be customized and optimized for your precision research.
DiagnoCine Precision buffers and reagents are Made in USA ISO 13485 Certified

One Stop Purchasing but Zero Compromise on Accuracy

Why waste time searching for your ELISA kit when you can get everything in one place? Diagnocine can provide you with all the ELISA needs you have (customized ELISAs also available) on the planet through a single, streamlined ordering process.  
* all types of species
* HRP and AP detection
* Low target signal enhancement
* Inquire about a trial version or a customized version

Low Signal Optimization Reagents

4 core reagents below are included with every order, plus 1 of the 2 detection-specific reagents (matched automatically to your kit type) — 5 components, every time.

DCP-PIC100X

Protease Inhibitor Cocktail (100X)

Included with every order
 DCP-SM1AbTBS1X

SigMax 1Ab-TBS

Included with every order
 DCP-UTBS1X

Universal Blocking Buffer

Included with every order
 DCP-SM2AbTBS1X

SigMax 2Ab-TBS

Included with every order

+ the 5th component, matched to your kit's detection method:

DCP-HRPTBS1X

HRPQuench-TBS

Exclusively for HRP-based kits
OR
DCP-ALPTBS1X

ALPQuench-TBS

Exclusively for ALP-based kits

If you have any questions or need additional information, please call us at 551-245-1033 or email us at support@diagnocine.com. Our team will be happy to assist you.

Key Value Highlights

Universal Compatibility

All buffers and detection reagents work seamlessly across target proteins, bridging the gap in assay consistency.

1-Stop Convenience

Consolidate your lab's purchasing. Source all ELISA needs and experience optimal buffers and reagents in a single shipment.

Enhanced Precision

Designed by scientists for scientists,  all components are engineered to deliver sharper results and an optical signal.

Human ELISA Kit · Immunology

Human Interleukin 12,IL-12/P70 ELISA KIT

Sandwich quantitative immunoassay for Human Interleukin 12,IL-12/P70 ELISA KIT in human serum, plasma, cell culture supernates  available in multiple catalog sizes:

Trial 24T 96T

Note: Please send inquiries regarding Trial 24T orders to support@diagnocine.com.

Detection Range
31.25-2,000 pg/ml
Sensitivity
7.8 pg/ml
Assay Time
1-5 hours
Sample Volume
50-100 μL
Product specifications
SpeciesHomo sapiens (Human)
Sample typesserum, plasma, cell culture supernates
Detection range31.25 pg/ml - 2000pg/ml
Sensitivity7.8 pg/ml
Assay time1-5h
Sample loading volume50-100μL
Detection wavelength450 nm
Assay principleSandwich (Quantitative)
Data analysisStandard curve + Curve Expert software
Research areaImmunology
Storage condition2-8°C (see protocol for full details)
Shipping condition4 °C
Shelf life6 months
Human Interleukin 12,IL-12/P70 ELISA KIT serum plasma cell culture supernates Immunology Human ELISA
Lead Time

10 business days

Processing + 3-5 days shipping

Availability

In Stock : USA

Worldwide shipping available

Assay principle
Sample prep
Antibody capture
450 nm detection
Standard curve
Quantification

In this sandwich ELISA, Human Interleukin 12,IL-12/P70 ELISA KIT in the sample is captured between a pre-coated capture antibody and a detection antibody. Signal intensity is proportional to analyte concentration. Quantification uses a standard curve fitted with Curve Expert software, covering 31.25 pg/ml - 2000pg/ml with a minimum detectable dose of 7.8 pg/ml.

For research use only (RUO). Not intended for diagnostic or therapeutic purposes. Validated in human serum, plasma, cell culture supernates matrices only.
Description

This Human IL-12/P70 ELISA Kit was designed for the quantitative measurement of Human IL-12/P70 protein in serum, plasma, cell culture supernates. It is a Sandwich ELISA kit, its detection range is 31.25 pg/ml-2000 pg/ml and the sensitivity is 7.8 pg/ml.

Materials provided
    • A micro ELISA plate ---The 96-well plate has been pre-coated with an anti-human IL-12 antibody. This dismountable microplate can be divided into 12 x 8 strip plates.
    • Two vials lyophilized standard ---Dilute a bottle of the standard at dilution series, read the OD values, and then draw a standard curve.
    • One vial Biotin-labeled IL-12 antibody (100 x concentrate) (120 μl/bottle) ---Act as the detection antibody.
    • One vial HRP-avidin (100 x concentrate) (120 μl/bottle) ---Bind to the detection antibody and react with the TMB substrate to make the solution chromogenic.
    • One vial Biotin-antibody Diluent (15 ml/bottle) ---Dilute the Biotin-antibody.
    • One vial HRP-avidin Diluent (15 ml/bottle) ---Dilute the HRP-avidin solution.
    • One vial Sample Diluent (50 ml/bottle)---Dilute the sample to an appropriate concentration.
    • One vial Wash Buffer (25 x concentrate) (20 ml/bottle) ---Wash away unbound or free substances.
    • One vial TMB Substrate (10 ml/bottle) ---Act as the chromogenic agent. TMB interacts with HRP, eliciting the solution turns blue.
    • One vial Stop Solution (10 ml/bottle) ---Stop the color reaction. The solution color immediately turns from blue to yellow.
    • Four Adhesive Strips (For 96 wells) --- Cover the microplate when incubation.
    • An instruction manual
Materials not provided
    • A microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm.
    • An incubator can provide stable incubation conditions up to 37°C±5°C.
    • Centrifuge
    • Vortex
    • Squirt bottle, manifold dispenser, or automated microplate washer
    • Absorbent paper for blotting the microtiter plate
    • 50-300ul multi-channel micropipette
    • Pipette tips
    • Single-channel micropipette with different ranges
    • 100ml and 500ml graduated cylinders
    • Deionized or distilled water
    • Timer
    • Test tubes for dilution

Satisfaction
Quality Rating
Value Rating
Style Rating
X