FluxMPS™ Minimum Essential Medium (MEM), High Glucose & 25mM HEPES w/o L-Glutamine, Sodium Bicarbonate: 1X Liquid

Product#: DCP-MEMGH-QBN1X
$44.00
DCP-MEMGH-QBN1X
Availability:
Ships in 1-2 Weeks

warning For Research Use Only (RUO). Not intended for clinical, diagnostic, or therapeutic use in humans.
ISO 13485 Certified Manufacturing

FluxMPS™ Minimum Essential Medium (MEM), High Glucose & 25mM HEPES w/o L-Glutamine, Sodium Bicarbonate: 1X Liquid

Contains Phenol Red Contains HEPES Contains Calcium Contains Magnesium Contains Glucose Contains Sodium Pyruvate Without L-Glutamine Without Sodium Bicarbonate

FluxMPS™ Minimum Essential Medium (MEM), High Glucose & 25mM HEPES w/o L-Glutamine, Sodium Bicarbonate: 1X Liquid is a Microfluidics Suitable, Quadruple-stage ultra-filtered (0.1 µm ×2 + 0.04 µm ×2) 1X liquid cell culture medium engineered for organ-on-a-chip (OoC), tissue-on-a-chip (ToC), and microphysiological system (MPS) applications. A quadruple-stage train (0.1 µm ×2 + 0.04 µm ×2) reaches a 0.04 µm final cut-off, five times finer than the 0.22 µm membranes used for conventional sterile filtration.

  • High-glucose (4.5 g/L) Minimum Essential Medium base with 12 essential amino acids — suited to high-energy-demand cell types
  • Quadruple-stage filtration: 0.1 µm (Prefiltration I & II) + 0.04 µm (Final filtration I & II — Polish)
  • Endotoxin release specification: < 0.05 EU/mL (USP <85> BET), verified per manufacturing batch
  • pH 7.4 (USP <791>); osmolality reported per batch on the Certificate of Analysis
  • Prepared with Ultrapure Type 1 water (18.2 MΩ·cm)
  • ISO Class 5 aseptic fill & finish; ISO 13485:2016 quality management system manufacturing
  • Bicarbonate-free, 25 mM HEPES-buffered formulation with reduced CO₂ dependence
  • Custom formulations available — pH, glucose, salts, HEPES, and nutrient composition on request
DCP-MEMGH-QBN1X | Cell Culture Media UNSPSC: 41116155 | Commodity: Molecular biology and cell culture growth media | (UNv260801)
Minimum Essential Medium (MEM), High Glucose & 25mM HEPES w/o L-Glutamine, Sodium Bicarbonate: 1X Liquid
  • Glucose4500 mg/L (4.5 g/L)
  • L-GlutamineNot added — supplement as needed
  • Sodium Pyruvate110 mg/L
  • HEPES5958 mg/L (25 mM)
  • Phenol Red11 mg/L (present)
  • pH (USP <791>)7.4
  • Osmolality (USP <785>)See Certificate of Analysis (batch-specific)
  • Endotoxin (USP <85>)< 0.05 EU/mL
  • Filtration0.1 µm ×2 + 0.04 µm ×2
  • Shelf Life12 months from date of manufacture, unopened
ISO 13485:2016 USP <85> <785> <788> RUO
Why FluxMPS™

Engineered where standard media fails

Conventional 0.22 µm-filtered media carry mycoplasma-sized particulates (0.2–0.3 µm), subvisible debris, and variable endotoxin loads that accumulate inside microchannels — corrupting biosensor readings, stressing primary cultures, and shortening device lifetimes. FluxMPS™ is built to avoid these failure modes.

filter_alt

Microchannel-safe purity

0.04 µm final filter retains particulates to sub-mycoplasma size; USP <788> Method 1 (light obscuration) particulate compliance verified per batch.

target

High-glucose metabolic support

4.5 g/L glucose supports high-energy-demand cell types including HeLa, MCF-7, fibroblasts, and iPSC-derived models in perfusion devices.

water_drop

Ultrapure-grade water

Prepared with Type 1 water (18.2 MΩ·cm), formulated under trace-metal and organic-carbon (TOC) control.

visibility

Low background for imaging

Quadruple-stage filtration minimizes particulate background — useful for confocal microscopy, live-cell biosensors, and TEER measurements. (Formulation contains phenol red; see Appearance.)

science

Rich, stable nutrient profile

Twelve essential amino acids plus a full vitamin panel, produced under micro-batch precision manufacturing for lot-to-lot nutrient consistency.

tune

Customization on demand

pH, glucose, salts, HEPES, and full nutrient composition available on request. Contact support@diagnocine.com.

Purity Architecture

Quadruple-stage filtration system

FluxMPS™ Minimum Essential Medium (MEM), High Glucose & 25mM HEPES w/o L-Glutamine, Sodium Bicarbonate: 1X Liquid is processed through a four-stage filtration train — two dedicated prefilter/final-filter pairs — reaching a 0.04 µm final pore size, addressing mycoplasma-scale and subvisible particulates that 0.22 µm filtration cannot.

  1. 1

    0.1 µm Prefiltration I

    Removes large particulates, cell debris and protein aggregates; protects the first 0.04 µm final filter cartridge.

  2. 2

    0.04 µm Final filtration I

    First 0.04 µm pass; retains sub-micron particulates and microaggregates that pass a 0.22 µm filter.

  3. 3

    0.1 µm Prefiltration II

    Second dedicated prefilter, protecting the second 0.04 µm final-filter cartridge for full-train redundancy.

  4. 4

    0.04 µm Final filtration II — Polish

    Ultimate polishing filter; ISO Class 5 aseptic fill and finish performed in a validated laminar-flow workstation.

Performance vs. conventional media

Four sequential stages reaching 0.04 µm deliver approximately 5× cleaner media by particulate count compared to single-pass 0.22 µm filtration.

5×
 
0.04
µm final filter pore size — sub-mycoplasma polishing
Sterility assurance: Every batch undergoes 14-day USP <71> sterility testing. Mycoplasma control is achieved through 0.1 µm mycoplasma-retentive filtration (not tested per lot); mycoplasma organisms are typically 0.2–0.3 µm in diameter.
Grade: This product is Microfluidics Suitable, filtered to a 0.04 µm final cut-off. It is not an MPS Grade product — that designation is reserved for the 0.01 µm ultra nano-filtered line, which adds 0.02 µm and 0.01 µm stages after the 0.04 µm polish. For applications requiring the 0.01 µm cut-off, contact support@diagnocine.com.
FluxMPS™ Minimum Essential Medium (MEM) High Glucose 25mM HEPES w/o L-Glutamine Sodium Bicarbonate 1X Liquid (DCP-MEMGH-QBN1X) Quadruple-stage filtration system: 0.1 micron Prefiltration I, 0.04 micron Final filtration I, 0.1 micron Prefiltration II, 0.04 micron Final filtration II Polish for organ-on-a-chip and microfluidic applications by Diagnocine
Figure 1. FluxMPS™ Quadruple-stage filtration architecture (0.1 µm ×2 + 0.04 µm ×2) delivering Microfluidics Suitable purity for MPS and OoC applications.
© Diagnocine® — DCP-MEMGH-QBN1X
Applications

Designed for next-generation cell culture platforms

FluxMPS™ Minimum Essential Medium (MEM), High Glucose & 25mM HEPES w/o L-Glutamine, Sodium Bicarbonate: 1X Liquid is suited to organ-on-a-chip, cancer biology, stem cell, vascular biology, metabolomics and live-cell imaging models where particulate contamination and endotoxin variation are unacceptable.

Automated Bioreactors & Robotics

Next-Generation System Uptime

An optional 0.01 µm (10 nm) ultra nano-filtered MPS Grade variant is available for automated bioreactor and robotic perfusion systems requiring the ultimate particulate exclusion.

  • Total Particulate Exclusion: 10 nm filtration for nanoscale valve and sensor protection
  • Valve & Sensor Protection: prevents particulate-induced blockage in precision fluidic systems
  • Extended Perfusion Stability: maintains flow rate consistency across multi-week automated runs

Inquiry Required: Contact support@diagnocine.com to request the 0.01 µm MPS Grade variant.

Microfluidics

Micro Physiological System (MPS) & Chip

Ultra-filtered formulation prevents microchannel clogging and maintains laminar flow integrity across complex chip geometries.

OoCToCBoCLoCMPS
Cancer Biology

Warburg Effect & Metabolic Research

High-glucose base supports Warburg effect studies and glucose uptake assays in cancer cell lines.

MCF-7MDA-MB-231HeLaHT-1080
Stem Cell Biology

iPSC-Derived Models

Low-particulate formulation supports sensitive iPSC differentiation protocols where variable endotoxin can cause off-target effects.

iPSC-NeuronsiPSC-CMiPSC-Hep
Vascular Biology

Endothelial & Primary Cells

Microchannel-safe purity supports endothelial barrier integrity and TEER measurement in perfusion models.

HUVECsBHK-21Primary fibroblasts
Metabolomics

Metabolic Flux Analysis

High-glucose base enables 13C isotope tracing and glycolytic flux experiments. Not compatible with Agilent Seahorse XF assays, which require bicarbonate-free, phenol red-free medium.

13C tracingNMR metabolomics
Live-Cell Imaging

Microscopy & Optical Sensing

Ultra-low particulate load supports high-content confocal imaging and optical biosensor integration; formulation contains phenol red (see specifications).

ConfocalBiosensorsTEER
Technical Specifications

Batch-release quality parameters

Every manufacturing batch of FluxMPS™ Minimum Essential Medium (MEM), High Glucose & 25mM HEPES w/o L-Glutamine, Sodium Bicarbonate: 1X Liquid undergoes the complete quality-release battery below before shipment.

Available pack sizes: 500 mL, 1000 mL.

Physical & Chemical Parameters
Parameter Specification
Formulation Minimum Essential Medium (MEM), High Glucose & 25mM HEPES w/o L-Glutamine, Sodium Bicarbonate: 1X Liquid
Appearance Orange-to-red colored, clear solution
pH USP <791> 7.4
Osmolality USP <785> See Certificate of Analysis (batch-specific)
Glucose 4500 mg/L (4.5 g/L)
L-Glutamine Not added — supplement as needed
Sodium Pyruvate 110 mg/L
Phenol Red 11 mg/L (present)
Sterility, Purity & Safety Parameters
Parameter Specification
Endotoxin USP <85> BET < 0.05 EU/mL
Sterility USP <71> No growth after 14 days
Mycoplasma 0.1 µm mycoplasma-retentive filtration (not tested per lot)
Particulate ≥10 µm USP <788> Method 1 Compliant
Particulate ≥25 µm USP <788> Method 1 Compliant
Water purity Ultrapure Type 1, 18.2 MΩ·cm
Manufacturing std. ISO 13485 ISO 13485:2016
Fill environment ISO Class 5 (Class 100)
Storage, Handling & Logistics
Parameter Specification
Storage temperature 2–8°C, protected from light
Freeze-thaw Not recommended
Shelf life 12 months from date of manufacture, unopened
Shipping condition Cold pack
CO₂ requirement HEPES-buffered; reduced CO₂ dependence (validate per cell line)
Raw Materials & Regulatory Traceability
Parameter Specification
Raw material grade Cell culture / reagent grade
Traceability Full lot documentation, CoA available
Manufacturing QMS ISO 13485:2016 certified
UNSPSC 41116155 — Molecular biology and cell culture growth media (UNv260801)
Regulatory alignment 21 CFR Part 820 (QMSR) aligned
Production method Micro-batch precision manufacturing
Intended use For Research Use Only (RUO)
Formulation

Full composition (mg/L)

Complete formulation with CAS numbers, reproduced from manufacturer specification — 29 components (5 inorganic salts, 12 amino acids, 8 vitamins, 4 others) across 3 tabbed views. Custom compositions available on request.

Component CAS Number mg/L
INORGANIC SALTS
Calcium chloride dihydrate 10035-04-8 265.000
Magnesium sulfate anhydrous 7487-88-9 97.720
Potassium chloride 7447-40-7 400.000
Sodium chloride 7647-14-5 6800.00
Sodium phosphate dibasic anhydrous 7558-79-4 122.000
Component CAS Number mg/L
AMINO ACIDS
L-Arginine hydrochloride 1119-34-2 126.000
L-Cystine dihydrochloride 30189-89-0 31.300
L-Histidine hydrochloride monohydrate 5934-29-2 42.000
L-Isoleucine 73-32-5 52.000
L-Leucine 61-90-5 52.000
L-Lysine hydrochloride 657-27-2 72.500
L-Methionine 63-68-3 15.000
L-Phenylalanine 63-91-2 32.000
L-Threonine 72-19-5 48.000
L-Tryptophan 73-22-3 10.000
L-Tyrosine disodium salt 69847-45-6 51.900
L-Valine 72-18-4 46.000
Component CAS Number mg/L
VITAMINS
Choline chloride 67-48-1 1.000
D-Ca-Pantothenate 137-08-6 1.000
Folic acid 59-30-3 1.000
Niacinamide 98-92-0 1.000
Pyridoxine hydrochloride 58-56-0 1.000
Riboflavin 83-88-5 0.100
Thiamine hydrochloride 67-03-8 1.000
i-Inositol 87-89-8 2.000
OTHERS
D-Glucose 50-99-7 4500.000
HEPES 7365-45-9 5958.000
Phenol red sodium salt 34487-61-1 11.000
Sodium Pyruvate 113-24-6 110.000
Customization: pH, glucose, salt balance, HEPES, and full nutrient profile available on request. Contact support@diagnocine.com.
Quality Assurance

ISO 13485:2016 manufacturing & compliance

Manufactured under an ISO 13485:2016 quality management system with final packaging, testing, and customization at Diagnocine, Totowa, New Jersey, USA.

verified

ISO 13485:2016 QMS

Full quality management system certification covering manufacturing, testing, and release for every production batch.

water_drop

Ultrapure Type 1 Water

All media prepared with 18.2 MΩ·cm resistivity water under trace-metal and organic-carbon (TOC) control.

biotech

ISO Class 5 Fill & Finish

Aseptic filling in validated ISO Class 5 laminar-flow workstations; 21 CFR Part 820 (QMSR) aligned.

assignment

Micro-Batch Precision

Small-batch manufacturing ensures lot-to-lot nutrient consistency for reproducible perfusion studies.

Endotoxin — USP <85> BET

LAL assay performed each manufacturing batch. Release specification: < 0.05 EU/mL.

Particulate — USP <788> Method 1

Light obscuration particle count confirms ≥10 µm and ≥25 µm compliance per batch.

Osmolality — USP <785>

Freezing-point osmometry per USP <785>. Result reported on the Certificate of Analysis (batch-specific).

Documentation — CoA & Full Batch Records

Certificate of Analysis with full QC panel, traceability, and release signatures for every batch.

Batch-level quality control. Endotoxin is controlled per manufacturing batch rather than per unit. Every batch is tested before release and must meet the release specification:
  • Endotoxin — LAL assay, USP <85> Bacterial Endotoxins Test; assay sensitivity 0.005 EU/mL; release specification < 0.05 EU/mL
  • pH, osmolality, conductivity, appearance and clarity
  • Sterility
A Certificate of Analysis is available on request via support@diagnocine.com.
Product Comparison

How DCP-MEMGH-QBN1X (FluxMPS™) compares

Side-by-side comparison against conventional 0.22 µm-filtered MEM High Glucose alternatives.

Parameter DCP-MEMGH-QBN1X (FluxMPS™) Conventional MEM High Glucose (0.22 µm) Standard MEM High Glucose alternative
Grade Microfluidics Suitable Not applicable (0.22 µm filtered) Not applicable (0.22 µm filtered)
Base Formulation Minimum Essential Medium (MEM), High Glucose & 25mM HEPES w/o L-Glutamine, Sodium Bicarbonate: 1X Liquid MEM High Glucose Standard MEM High Glucose Equivalent
Final filtration pore size 0.04 µm 0.22 µm 0.22 µm
Number of filtration stages 4 stages 1 stage 1–2 stages
Mycoplasma-retentive filtration check_circle cancel cancel
Endotoxin (release specification) FluxMPS™ — < 0.05 EU/mL Corning classical liquid media — < 0.25 EU/mL
Sigma-Aldrich DMEM complete medium — ≤ 2 EU/mL
Gibco classical DMEM — Not specified (recorded per lot)
USP particulate compliance check_circle USP <788> Method 1 cancel cancel
Water quality Ultrapure Type 1 (18.2 MΩ) Purified water Purified water
Manufacturing QMS ISO 13485:2016 Variable Variable
Microfluidic channel compatibility check_circle Validated cancel Risk of clogging cancel Risk of clogging
Custom formulation check_circle On request cancel Limited

Comparison figures from published supplier specifications, accessed 2026-09-02. Suppliers that publish no numeric endotoxin specification are shown as "Not specified".

FAQ

Frequently asked questions

Common questions about FluxMPS™ Minimum Essential Medium (MEM), High Glucose & 25mM HEPES w/o L-Glutamine, Sodium Bicarbonate: 1X Liquid and Microfluidics Suitable cell culture media.

Yes. DCP-MEMGH-QBN1X uses our Quadruple-stage filtration (0.1 µm ×2 + 0.04 µm ×2), delivering ultra-low particulate counts that help prevent microchannel clogging in OoC and MPS devices. It is Microfluidics Suitable at a 0.04 µm final cut-off.
Standard 0.22 µm filtration leaves intact mycoplasma-scale (0.2–0.3 µm) and subvisible particulates that can accumulate in microchannels. FluxMPS™ uses four sequential stages — two 0.1 µm prefilter and 0.04 µm final-filter pairs — delivering approximately 5× lower particulate counts by count, verified against USP <788> Method 1.
The 4.5 g/L glucose level supports metabolically demanding cell types including HeLa, MCF-7, fibroblasts, and high-density suspension cultures. L-Glutamine is not included in this formulation and should be added at the time of use, typically at 2–4 mM (or as GlutaMAX). Contact support@diagnocine.com for a custom glucose or amino-acid formulation.
This formulation is bicarbonate-free and buffered with 25 mM HEPES, reducing CO₂ dependence. Reduced or ambient-CO₂ incubation is generally compatible; validate against your specific cell line and assay.
Yes. FluxMPS™ Minimum Essential Medium (MEM), High Glucose & 25mM HEPES w/o L-Glutamine, Sodium Bicarbonate: 1X Liquid can be supplemented with FBS (5–20%), growth factors, L-Glutamine, or antibiotics per standard practice. When filtering serum-containing supplements, use a 0.2 µm low-protein-binding PES or PVDF membrane — never 0.04 µm, which retains IgM, VLDL and other serum proteins. Add supplements immediately before use.
Endotoxin is controlled per manufacturing batch, not per unit. Every batch is tested by LAL assay per USP <85> Bacterial Endotoxins Test (assay sensitivity 0.005 EU/mL) and must meet the release specification of < 0.05 EU/mL before shipment. Batch-specific results are documented in the Certificate of Analysis, available from support@diagnocine.com.
Yes. A batch-specific CoA is available for every shipment and includes: appearance, pH (USP <791>), osmolality (USP <785>), endotoxin (USP <85> BET), sterility (USP <71>), particulate matter (USP <788> Method 1), raw material traceability, manufacturing date, and authorized release signatures. Request via support@diagnocine.com.
Scientific References

Supporting literature

Peer-reviewed publications supporting Microfluidics Suitable ultra-filtered media and microfluidic cell culture applications.

  1. Huh D et al. (2010). Reconstituting organ-level lung functions on a chip. Science, 328(5986), 1662–1668. doi:10.1126/science.1188302
  2. Bhatia SN & Ingber DE (2014). Microfluidic organs-on-chips. Nature Biotechnology, 32(8), 760–772. doi:10.1038/nbt.2989
  3. Eagle H (1959). Amino acid metabolism in mammalian cell cultures. Science, 130(3373), 432–437. doi:10.1126/science.130.3373.432
  4. Warburg O (1956). On the origin of cancer cells. Science, 123(3191), 309–314. doi:10.1126/science.123.3191.309
  5. Bhattacharya S et al. (2018). Challenges in maintaining cell viability during microfluidic experiments. Electrophoresis, 39(7), 997–1006. doi:10.1002/elps.201700375
  6. Zhang YS et al. (2017). Multisensor-integrated organs-on-chips for automated in situ monitoring. PNAS, 114(12), E2293–E2302. doi:10.1073/pnas.1612906114
  7. Vernetti L et al. (2017). Functional coupling of human microphysiology systems. Scientific Reports, 7, 42296. doi:10.1038/srep42296
  8. Esch EW et al. (2015). Organs-on-chips at the frontiers of drug discovery. Nature Reviews Drug Discovery, 14(4), 248–260. doi:10.1038/nrd4539
  9. Zheng F et al. (2021). Organ-on-a-chip systems: microengineering to biomimic living systems. Small, 17(7), 2004175. doi:10.1002/smll.202004175

Satisfaction
Quality Rating
Value Rating
Style Rating
X