FluxMPS™ Minimum Essential Medium (MEM), Low Glucose w/o L-Glutamine, Sodium Pyruvate, Sodium Bicarbonate, Phenol Red: 1X Liquid

Product#: DCP-MEM-QPBRN1X
$34.10
DCP-MEM-QPBRN1X
Availability:
Ships in 1-2 Weeks

warning For Research Use Only (RUO). Not intended for clinical, diagnostic, or therapeutic use in humans.
ISO 13485 Certified Manufacturing

FluxMPS™ Minimum Essential Medium (MEM), Low Glucose w/o L-Glutamine, Sodium Pyruvate, Sodium Bicarbonate, Phenol Red: 1X Liquid

Contains Calcium Contains Magnesium Contains Glucose Without L-Glutamine Without Sodium Bicarbonate Without Phenol Red Without HEPES Without Sodium Pyruvate

FluxMPS™ Minimum Essential Medium (MEM), Low Glucose w/o L-Glutamine, Sodium Pyruvate, Sodium Bicarbonate, Phenol Red: 1X Liquid is a Microfluidics Suitable, ultra-filtered cell culture medium engineered for organ-on-a-chip (OoC), tissue-on-a-chip (ToC), and microphysiological system (MPS) applications. A quadruple-stage train (0.1 µm ×2 + 0.04 µm ×2) reaches a 0.04 µm final cut-off, five times finer than the 0.22 µm membranes used for conventional sterile filtration. This bicarbonate-free, phenol red-free MEM base is supplied without L-Glutamine and sodium pyruvate so researchers can supplement each at defined, assay-specific concentrations.

  • Quadruple-stage filtration: 0.1 µm (Prefiltration I & II) alternating with 0.04 µm (Final filtration I & II — Polish), reaching a 0.04 µm final pore size
  • Endotoxin release specification: < 0.05 EU/mL (USP <85> BET, tested per manufacturing batch)
  • MEM Low Glucose base (1000 mg/L D-Glucose); pH 7.4 (USP <791>)
  • Supplied without L-Glutamine, sodium pyruvate, sodium bicarbonate, HEPES, and phenol red — a fully customizable base for defined supplementation
  • Prepared with Ultrapure Type 1 water (18.2 MΩ·cm)
  • ISO Class 5 aseptic fill & finish; ISO 13485:2016 QMS manufacturing
  • Mycoplasma risk mitigated via 0.1 µm mycoplasma-retentive filtration (not tested per lot)
  • Custom formulations available — pH, glucose, salts, HEPES, and nutrient composition on request
DCP-MEM-QPBRN1X | Cell Culture Media UNSPSC: 41116155 | Commodity: Molecular biology and cell culture growth media | (UNv260801)
Minimum Essential Medium (MEM), Low Glucose w/o L-Glutamine, Sodium Pyruvate, Sodium Bicarbonate, Phenol Red: 1X Liquid
  • Glucose1000 mg/L (1.0 g/L)
  • L-GlutamineNot present — supplement as needed
  • Sodium PyruvateNot present — supplement as needed
  • HEPESNot present
  • pH (USP <791>)7.4
  • Osmolality (USP <785>)See Certificate of Analysis (lot-specific)
  • Endotoxin (USP <85>)< 0.05 EU/mL
  • Filtration0.1 µm ×2 + 0.04 µm ×2
  • Storage2–8°C, protect from light
  • Shelf Life12 months from date of manufacture, unopened
Available pack sizes: 500 mL, 1000 mL.
ISO 13485:2016 USP <85> <785> <788> RUO
Why FluxMPS™

Engineered where standard media fails

Conventional 0.22 µm-filtered media carry mycoplasma-sized particulates (0.2–0.3 µm), subvisible debris, and inconsistent endotoxin levels that accumulate inside microchannels — corrupting biosensor readings and shortening device lifetimes. FluxMPS™ addresses these failure modes at the filtration stage.

filter_alt

Microchannel-safe purity

0.04 µm final filter retains particles to sub-mycoplasma size; USP <788> Method 1 particulate compliance verified per lot.

target

Total metabolic control

Supplied without L-Glutamine, sodium pyruvate, and sodium bicarbonate, giving full control over carbon source and buffer system for metabolic flux experiments and Warburg-pathway studies.

water_drop

Ultrapure-grade water

Prepared with Type 1 water (18.2 MΩ·cm) with tightly controlled trace-metal and organic carbon (TOC) content for consistent performance in sensitive assays.

visibility

Low background for imaging

Ultra-low particulate baseline supports confocal microscopy, live-cell biosensors, and TEER measurements; a phenol red-free, bicarbonate-free formulation avoids the optical interference these compounds introduce.

science

Rich, stable nutrient profile

Micro-batch precision locks in amino acid and vitamin concentrations for lot-to-lot reproducibility in long-term perfusion studies.

tune

Customization on demand

pH, glucose, salts, HEPES, and full nutrient composition available on request. Contact support@diagnocine.com.

Purity Architecture

Quadruple-stage filtration system

FluxMPS™ Minimum Essential Medium (MEM), Low Glucose w/o L-Glutamine, Sodium Pyruvate, Sodium Bicarbonate, Phenol Red: 1X Liquid is processed through a four-pass, paired prefilter and final-filter sequence reaching a 0.04 µm final pore size — addressing mycoplasma-range organisms and subvisible particulates that 0.22 µm filtration cannot reliably retain.

  1. 1

    0.1 µm Prefiltration I

    Removes large particulates, cell debris, and protein aggregates; protects the first 0.04 µm final filter cartridge.

  2. 2

    0.04 µm Final filtration I

    First 0.04 µm pass; retains sub-micron particulates and microaggregates, including mycoplasma-range organisms (0.2–0.3 µm), that pass through a standard 0.22 µm filter.

  3. 3

    0.1 µm Prefiltration II

    Second dedicated prefilter; protects the second 0.04 µm cartridge and provides redundant particulate removal ahead of the final polish.

  4. 4

    0.04 µm Final filtration II — Polish

    Ultimate polishing filter; aseptic fill and finish in a validated ISO Class 5 laminar-flow workstation under GMP-aligned conditions.

Performance vs. conventional media

Four sequential passes reaching 0.04 µm deliver approximately 5× cleaner media by particulate count compared to single-pass 0.22 µm filtration, with USP <788> Method 1 compliance verified on every lot.

5×
 
0.04
µm final filter pore size — sub-mycoplasma polishing
Sterility assurance: Every lot undergoes 14-day USP <71> sterility testing. Mycoplasma risk is mitigated through 0.1 µm mycoplasma-retentive filtration; this control is not equivalent to, and does not replace, a USP <63> mycoplasma detection assay performed on the lot.
Grade: This product is Microfluidics Suitable, filtered to a 0.04 µm final cut-off. It is not an MPS Grade product — that designation is reserved for the 0.01 µm ultra nano-filtered line, which adds 0.02 µm and 0.01 µm stages after the 0.04 µm polish. For applications requiring the 0.01 µm cut-off, contact support@diagnocine.com.
FluxMPS(TM) Minimum Essential Medium (MEM), Low Glucose w/o L-Glutamine, Sodium Pyruvate, Sodium Bicarbonate, Phenol Red: 1X Liquid (DCP-MEM-QPBRN1X) Quadruple-stage filtration system: 0.1 micron Prefiltration I, 0.04 micron Final filtration I, 0.1 micron Prefiltration II, 0.04 micron Final filtration II Polish for organ-on-a-chip and microfluidic applications by Diagnocine
Figure 1. FluxMPS™ Quadruple-stage filtration architecture (0.1 µm ×2 + 0.04 µm ×2).
© Diagnocine® — DCP-MEM-QPBRN1X
Applications

Designed for next-generation cell culture platforms

FluxMPS™ Minimum Essential Medium (MEM), Low Glucose w/o L-Glutamine, Sodium Pyruvate, Sodium Bicarbonate, Phenol Red: 1X Liquid is validated for organ-on-a-chip, metabolic research, live-cell imaging, and primary cell models where particulate contamination and endotoxin variability are unacceptable.

Automated Bioreactors & Robotics

Next-Generation System Uptime

An optional 0.01 µm (10 nm) MPS Grade variant is available for automated bioreactor and robotic perfusion systems requiring the ultimate particulate exclusion.

  • Total Particulate Exclusion: 10 nm filtration for nanoscale valve and sensor protection
  • Valve & Sensor Protection: prevents particulate-induced blockage in precision fluidic systems
  • Extended Perfusion Stability: maintains flow rate consistency across multi-week automated runs

Inquiry Required: Contact support@diagnocine.com to request the 0.01 µm MPS Grade line.

Microfluidics

Micro Physiological System (MPS) & Chip

Ultra-filtered formulation prevents microchannel clogging and maintains laminar flow integrity.

OoCToCBoCLoCMPS
Cancer Biology

Warburg Effect & Metabolic Research

Defined, adjustable carbon source and low-endotoxin background enable precise metabolic flux analysis.

MCF-7MDA-MB-231HeLaHT-1080
Stem Cell Biology

iPSC-Derived Models

Ultrapure, customizable formulation supports sensitive iPSC differentiation protocols where endotoxin causes off-target effects.

iPSC-NeuronsiPSC-CMiPSC-Hep
Vascular Biology

Endothelial & Primary Cells

Microchannel-safe purity essential for maintaining endothelial barrier integrity and TEER values.

HUVECsBHK-21Primary fibroblasts
Metabolomics

Metabolic Flux Analysis

Chemically defined, fully characterized base supports isotope tracing and flux analysis. Its bicarbonate-free, phenol red-free formulation is also compatible with Agilent Seahorse XF real-time metabolic assays, which require both conditions.

13C tracingSeahorse XFNMR metabolomics
Live-Cell Imaging

Microscopy & Optical Sensing

Ultra-low particulate load supports confocal imaging, biosensor integration, and TEER measurement in sensitive optical assays.

ConfocalBiosensorsTEER
Technical Specifications

Lot-release quality parameters

Every production batch of FluxMPS™ Minimum Essential Medium (MEM), Low Glucose w/o L-Glutamine, Sodium Pyruvate, Sodium Bicarbonate, Phenol Red: 1X Liquid undergoes the complete quality-release battery below before shipment.

Physical & Chemical Parameters
Parameter Specification
Formulation Minimum Essential Medium (MEM), Low Glucose w/o L-Glutamine, Sodium Pyruvate, Sodium Bicarbonate, Phenol Red: 1X Liquid
Appearance Pale yellow, clear solution
pH USP <791> 7.4
Osmolality USP <785> See Certificate of Analysis (lot-specific)
Glucose 1000 mg/L (1.0 g/L)
L-Glutamine Not present — supplement as needed
Sodium Pyruvate Not present — supplement as needed
Phenol Red Not present
Sterility, Purity & Safety Parameters
Parameter Specification
Endotoxin USP <85> BET < 0.05 EU/mL
Sterility USP <71> No growth after 14 days
Mycoplasma 0.1 µm mycoplasma-retentive filtration (not tested per lot)
Particulate ≥10 µm USP <788> Method 1 Compliant
Particulate ≥25 µm USP <788> Method 1 Compliant
Water purity Ultrapure Type 1, 18.2 MΩ·cm
Manufacturing std. ISO 13485 ISO 13485:2016
Fill environment ISO Class 5 (Class 100)
Storage, Handling & Logistics
Parameter Specification
Storage temperature 2–8°C, protected from light
Freeze-thaw Not recommended
Shelf life 12 months from date of manufacture, unopened
Shipping condition Ambient or cold pack
CO₂ requirement Optional — contains neither sodium bicarbonate nor HEPES; buffer as needed for extended culture
Raw Materials & Regulatory Traceability
Parameter Specification
Raw material grade Cell culture / reagent grade
Traceability Full lot documentation, CoA available
Manufacturing QMS ISO 13485:2016 certified
UNSPSC 41116155 — Molecular biology and cell culture growth media (UNv260801)
Regulatory alignment 21 CFR Part 820 (QMSR) aligned
Production method Micro-batch precision manufacturing
Intended use For Research Use Only (RUO)
Formulation

Full composition (mg/L)

Complete formulation with CAS numbers, reproduced from manufacturer specification. Total: 26 components across 4 categories (Inorganic Salts, Amino Acids, Vitamins, Others). Custom compositions available on request.

Component CAS Number mg/L
INORGANIC SALTS
Calcium chloride dihydrate 10035-04-8 265.000
Magnesium sulfate anhydrous 7487-88-9 97.720
Potassium chloride 7447-40-7 400.000
Sodium chloride 7647-14-5 6800.00
Sodium phosphate dibasic anhydrous 7558-79-4 122.000
Component CAS Number mg/L
AMINO ACIDS
L-Arginine hydrochloride 1119-34-2 126.000
L-Cystine dihydrochloride 30189-89-0 31.300
L-Histidine hydrochloride monohydrate 5934-29-2 42.000
L-Isoleucine 73-32-5 52.000
L-Leucine 61-90-5 52.000
L-Lysine hydrochloride 657-27-2 72.500
L-Methionine 63-68-3 15.000
L-Phenylalanine 63-91-2 32.000
L-Threonine 72-19-5 48.000
L-Tryptophan 73-22-3 10.000
L-Tyrosine disodium salt 69847-45-6 51.900
L-Valine 72-18-4 46.000
Component CAS Number mg/L
VITAMINS
Choline chloride 67-48-1 1.000
D-Ca-Pantothenate 137-08-6 1.000
Folic acid 59-30-3 1.000
Niacinamide 98-92-0 1.000
Pyridoxine hydrochloride 58-56-0 1.000
Riboflavin 83-88-5 0.100
Thiamine hydrochloride 67-03-8 1.000
OTHERS
i-Inositol 87-89-8 2.000
D-Glucose 50-99-7 1000.000
Customization: pH, glucose, salt balance, HEPES, and full nutrient profile available on request. Contact support@diagnocine.com.
Quality Assurance

ISO 13485:2016 manufacturing & compliance

Manufactured under ISO 13485:2016 QMS with final packaging, testing, and customization at Diagnocine Precision in Totowa, New Jersey, USA.

verified

ISO 13485:2016 QMS

Full quality management system certification covering manufacturing, testing, and release for every production batch.

water_drop

Ultrapure Type 1 Water

All media prepared with 18.2 MΩ·cm resistivity water with tightly controlled trace-metal and organic carbon content.

biotech

ISO Class 5 Fill & Finish

Aseptic filling in validated ISO Class 5 laminar-flow workstations; 21 CFR Part 820 (QMSR) aligned.

assignment

Micro-Batch Precision

Small-batch manufacturing ensures lot-to-lot nutrient consistency for reproducible perfusion studies.

Endotoxin — USP <85> BET

LAL assay on every batch. Release specification: < 0.05 EU/mL.

Particulate — USP <788> Method 1

Light obscuration particle count confirms ≥10 µm and ≥25 µm compliance per lot.

Osmolality — USP <785>

Freezing-point osmometry per USP <785>. Result: see Certificate of Analysis.

Documentation — CoA & Full Lot Records

Certificate of Analysis with full QC panel, traceability, and release signatures for every batch.

Batch-level quality control. Endotoxin is controlled per manufacturing batch rather than per unit. Every batch is tested before release and must meet the release specification:
  • Endotoxin — LAL assay, USP <85> Bacterial Endotoxins Test; assay sensitivity 0.005 EU/mL; release specification < 0.05 EU/mL
  • pH, osmolality, conductivity, appearance and clarity
  • Sterility
A Certificate of Analysis is available on request via support@diagnocine.com with your lot number.
Product Comparison

How DCP-MEM-QPBRN1X (FluxMPS™) compares

Side-by-side comparison against conventional 0.22 µm-filtered alternatives of the same base formulation, and published supplier endotoxin specifications.

Parameter DCP-MEM-QPBRN1X (FluxMPS™) Conventional MEM (0.22 µm) Standard MEM alternative
Grade Microfluidics Suitable Not applicable Not applicable
Base Formulation MEM, Low Glucose w/o L-Glutamine, Sodium Pyruvate, Sodium Bicarbonate, Phenol Red MEM Standard MEM Equivalent
Final filtration pore size 0.04 µm 0.22 µm 0.22 µm
Number of filtration stages 4 stages 1 stage 1–2 stages
Mycoplasma barrier filtration check_circle cancel cancel
Endotoxin (release specification) < 0.05 EU/mL Corning classical liquid media — < 0.25 EU/mL
Sigma-Aldrich DMEM complete medium — ≤ 2 EU/mL
Gibco classical DMEM — Not specified (recorded per lot)
USP particulate compliance check_circle USP <788> Method 1 cancel cancel
Water quality Ultrapure Type 1 (18.2 MΩ) Purified water Purified water
Manufacturing QMS ISO 13485:2016 Variable Variable
Microfluidic channel compatibility check_circle Validated cancel Risk of clogging cancel Risk of clogging
Custom formulation check_circle On request cancel Limited

Comparison figures from published supplier specifications, accessed 2026-09-02. Suppliers that publish no numeric endotoxin specification are shown as "Not specified".

FAQ

Frequently asked questions

Common questions about FluxMPS™ Minimum Essential Medium (MEM), Low Glucose w/o L-Glutamine, Sodium Pyruvate, Sodium Bicarbonate, Phenol Red: 1X Liquid and Microfluidics Suitable cell culture media.

Yes. This formulation is Microfluidics Suitable, processed through our Quadruple-stage filtration system (0.1 µm ×2 + 0.04 µm ×2), delivering ultra-low particulate counts that prevent microchannel clogging in OoC, ToC, BoC, and other MPS devices. Its bicarbonate-free, phenol red-free composition also supports optical and biosensor-based chip readouts.
Standard 0.22 µm filtration leaves intact mycoplasma-sized organisms (0.2–0.3 µm) and subvisible particulates that accumulate in microchannels over time. FluxMPS™ uses four sequential filtration passes (0.1 µm, 0.04 µm, 0.1 µm, 0.04 µm) reaching a 0.04 µm final pore size, delivering approximately 5× lower particulate counts by count compared to single-pass 0.22 µm media, with USP <788> Method 1 (light obscuration) particulate compliance verified on every lot.
This MEM base is supplied without these four components so researchers can add them at defined concentrations matched to their specific cell line and assay. Typical supplementation: L-Glutamine to 2 mM (or a stabilized dipeptide substitute for extended culture), sodium pyruvate to 1 mM (~110 mg/L) for enhanced energy metabolism, sodium bicarbonate (for CO2-buffered incubation) or HEPES 10–25 mM (for CO2-independent conditions), and phenol red only if visual pH monitoring is required — note that phenol red interferes with fluorescence, TEER, and Agilent Seahorse XF measurements. Contact support@diagnocine.com for a custom pre-formulated version.
No. This formulation contains neither sodium bicarbonate nor HEPES buffer, so CO2 supplementation is optional. For extended culture, add sodium bicarbonate for a CO2-buffered system or HEPES (10–25 mM) for CO2-independent buffering.
Yes. This formulation can be supplemented with FBS (5–20%), growth factors, antibiotics, or other additives per standard practice. When adding serum or protein-containing supplements, filter through a 0.2 µm low-protein-binding PES or PVDF membrane; protein-free additions may be filtered at 0.1 µm. Do not use 0.04 µm filters for supplementation — they retain serum proteins, lipoproteins, and growth factors. Add supplements immediately before use.
Endotoxin is controlled per manufacturing batch, not per individual unit. Every batch is tested by LAL assay (USP <85> Bacterial Endotoxins Test, assay sensitivity 0.005 EU/mL) before release and must meet the release specification of < 0.05 EU/mL. Batch-specific results are documented in the Certificate of Analysis, available from support@diagnocine.com.
Yes. A batch-specific CoA is available for every shipment and includes: appearance, pH (USP <791>), osmolality (USP <785>), endotoxin (USP <85> BET), sterility (USP <71>), particulate matter (USP <788> Method 1), raw material traceability, manufacturing date, expiry, and authorized release signatures. Request via support@diagnocine.com with your lot number.
Scientific References

Supporting literature

Peer-reviewed publications supporting Microfluidics Suitable ultra-filtered media and microfluidic cell culture applications.

  1. Huh D et al. (2010). Reconstituting organ-level lung functions on a chip. Science, 328(5986), 1662–1668. doi:10.1126/science.1188302
  2. Bhatia SN & Ingber DE (2014). Microfluidic organs-on-chips. Nature Biotechnology, 32(8), 760–772. doi:10.1038/nbt.2989
  3. Eagle H (1959). Amino acid metabolism in mammalian cell cultures. Science, 130(3373), 432–437. doi:10.1126/science.130.3373.432
  4. Bhattacharya S et al. (2018). Challenges in maintaining cell viability during microfluidic experiments. Electrophoresis, 39(7), 997–1006. doi:10.1002/elps.201700375
  5. Zhang YS et al. (2017). Multisensor-integrated organs-on-chips platform for automated in situ monitoring. PNAS, 114(12), E2293–E2302. doi:10.1073/pnas.1612906114
  6. Vernetti L et al. (2017). Functional coupling of human microphysiology systems. Scientific Reports, 7, 42296. doi:10.1038/srep42296
  7. Esch EW et al. (2015). Organs-on-chips at the frontiers of drug discovery. Nature Reviews Drug Discovery, 14(4), 248–260. doi:10.1038/nrd4539
  8. Zheng F et al. (2021). Organ-on-a-chip systems: microengineering to biomimic living systems. Small, 17(7), 2004175. doi:10.1002/smll.202004175

Satisfaction
Quality Rating
Value Rating
Style Rating