/Content/Upload/Product/Human_ELISA_kits_Diagnocine_1200_1200(81).jpg

Human tissue inhibitors of metalloproteinase 3,TIMP-3 ELISA Kit

Product#: CS-CSB-E04734h
$730.80
Availability:
Ships in 24 hours

The Ultimate 1-Stop ELISA Marketplace:

60,000+ ELISA kits Available to Serve Scientists from All Fields of Life Science

Always Powered by Diagnocine for Precision Research.

 
Made In-USA · ISO 13485 Certified 

Most comprehensive buffers, reagents and detection agents are provided with each kit to optimize data output.  
All-inclusive format covers everything from sample preparation to signal detection.  Every step can be customized and optimized for your precision research.
DiagnoCine Precision buffers and reagents are Made in USA ISO 13485 Certified

One Stop Purchasing but Zero Compromise on Accuracy

Why waste time searching for your ELISA kit when you can get everything in one place? Diagnocine can provide you with all the ELISA needs you have (customized ELISAs also available) on the planet through a single, streamlined ordering process.  
* all types of species
* HRP and AP detection
* Low target signal enhancement
* Inquire about a trial version or a customized version

Low Signal Optimization Reagents

4 core reagents below are included with every order, plus 1 of the 2 detection-specific reagents (matched automatically to your kit type) — 5 components, every time.

DCP-PIC100X

Protease Inhibitor Cocktail (100X)

Included with every order
 DCP-SM1AbTBS1X

SigMax 1Ab-TBS

Included with every order
 DCP-UTBS1X

Universal Blocking Buffer

Included with every order
 DCP-SM2AbTBS1X

SigMax 2Ab-TBS

Included with every order

+ the 5th component, matched to your kit's detection method:

DCP-HRPTBS1X

HRPQuench-TBS

Exclusively for HRP-based kits
OR
DCP-ALPTBS1X

ALPQuench-TBS

Exclusively for ALP-based kits

If you have any questions or need additional information, please call us at 551-245-1033 or email us at support@diagnocine.com. Our team will be happy to assist you.

Key Value Highlights

Universal Compatibility

All buffers and detection reagents work seamlessly across target proteins, bridging the gap in assay consistency.

1-Stop Convenience

Consolidate your lab's purchasing. Source all ELISA needs and experience optimal buffers and reagents in a single shipment.

Enhanced Precision

Designed by scientists for scientists,  all components are engineered to deliver sharper results and an optical signal.

Human ELISA Kit · Cancer

Human tissue inhibitors of metalloproteinase 3,TIMP-3 ELISA Kit

Sandwich quantitative immunoassay for TIMP metallopeptidase inhibitor 3 in human serum, plasma, tissue homogenates  available in multiple catalog sizes:

Trial 24T 96T

Note: Please send inquiries regarding Trial 24T orders to support@diagnocine.com.

Detection Range
31.25-2,000 pg/ml
Sensitivity
7.8 pg/ml
Assay Time
1-5 hours
Sample Volume
50-100 μL
Product specifications
Target nameTIMP metallopeptidase inhibitor 3
Uniprot No.P35625
SpeciesHomo sapiens (Human)
Sample typesserum, plasma, tissue homogenates
Detection range31.25 pg/ml-2000 pg/ml
Sensitivity7.8 pg/ml
Assay time1-5h
Sample loading volume50-100μL
Detection wavelength450 nm
Assay principleSandwich (Quantitative)
Data analysisStandard curve + Curve Expert software
Research areaCancer
Storage condition2-8°C (see protocol for full details)
Shipping condition4 °C
Shelf life6 months
TIMP metallopeptidase inhibitor 3 serum plasma tissue homogenates Cancer Human ELISA
Lead Time

10 business days

Processing + 3-5 days shipping

Availability

In Stock : USA

Worldwide shipping available

Assay principle
Sample prep
Antibody capture
450 nm detection
Standard curve
Quantification

In this sandwich ELISA, TIMP metallopeptidase inhibitor 3 in the sample is captured between a pre-coated capture antibody and a detection antibody. Signal intensity is proportional to analyte concentration. Quantification uses a standard curve fitted with Curve Expert software, covering 31.25 pg/ml-2000 pg/ml with a minimum detectable dose of 7.8 pg/ml.

For research use only (RUO). Not intended for diagnostic or therapeutic purposes. Validated in human serum, plasma, tissue homogenates matrices only.
Description

The ELISA Kit is designed for quantitatively measuring human TIMP3 levels in samples, including serum, plasma, or tissue homogenates. It uses the sandwich enzyme immunoassay technique in combination with the enzyme-substrate chromogenic reaction to quantify the analyte in the sample. The color develops positively to the amount of TIMP3 in samples. The color intensity is measured at 450 nm via a microplate reader.

TIMP3 has the broadest range of inhibition, targeting all members of the matrix metalloproteinase (MMP) family and several members of a disintegrin and metalloproteinases (ADAMs), and ADAM with thrombospondin motifs (ADAMTSs) family. Independent of its inhibitory capabilities, TIMP3 is also involved in promoting cell proliferation and regulating angiogenesis and apoptosis. The absence of TIMP3 results in poor cardiac remodeling and has been related to myocardial infarction or hypertension. In cancer studies, TIMP3 plays an important role in the cancer hallmark by controlling cell death, angiogenesis, tumor inflammation, and tumor cell invasion and dissemination.

Alternative Names
HSMRK222 ELISA Kit; K222 ELISA Kit; K222TA2 ELISA Kit; Metalloproteinase inhibitor 3 ELISA Kit; MIG 5 protein ELISA Kit; MIG5 protein ELISA Kit; Protein MIG 5 ELISA Kit; Protein MIG-5 ELISA Kit; SFD ELISA Kit; Sorsby fundus dystrophy pseudoinflammatory ELISA Kit; TIMP 3 ELISA Kit; TIMP metallopeptidase inhibitor 3 ELISA Kit; TIMP-3 ELISA Kit; TIMP3 ELISA Kit; TIMP3_HUMAN ELISA Kit; Tissue Inhibitor of Metalloproteinase 3 ELISA Kit; Tissue inhibitor of metalloproteinases 3 ELISA Kit; Tissue inhibitor of metalloproteinases3 ELISA Kit
Function
Complexes with metalloproteinases (such as collagenases) and irreversibly inactivates them by binding to their catalytic zinc cofactor. May form part of a tissue-specific acute response to remodeling stimuli. Known to act on MMP-1, MMP-2, MMP-3, MMP-7, MMP-9, MMP-13, MMP-14 and MMP-15.
Gene References into Functions
  1. The expression level of LIPC, SLC16A8, and TIMP-3 was significantly associated with age-related macular degeneration pathology. PMID: 27966779
  2. Of the 225 genetic tests performed, 150 were for recessive IRD, and 75 were for dominant IRD. A positive molecular diagnosis was made in 70 (59%) of probands with recessive IRD and 19 (26%) probands with dominant IRD. Thirty-two novel variants were identified; among these, 17 sequence changes in four genes were predicted to be possibly or probably damaging including: ABCA4 (14), BEST1 (2), PRPH2 (1), and TIMP3 PMID: 28005406
  3. Single Nucleotide Variants of Candidate Genes in Aggrecan Metabolic Pathway Are Associated with Lumbar Disc Degeneration and Modic Changes PMID: 28081267
  4. Plasma TIMP3 is a biomarker for predicting the tumor stage in patients with oral squamous cell carcinoma . PMID: 28138307
  5. TIMP3 overexpression after myocardial infarction improves myocardial structural remodeling and function by promoting angiogenesis and inhibiting early proteolysis. PMID: 28550172
  6. Sphingosine-1-phosphate inhibited cell migration and MMP-2 expression through the upregulation of the tissue inhibitor of metalloproteinase-3 (TIMP-3) expression in human chondrosarcoma cells. PMID: 28672103
  7. Collectively, these results demonstrated that IL-32alpha upregulates the atheroprotective genes Timp3 and Reck by downregulating microRNA-205 through regulation of the Rprd2-Dgcr8/Ddx5-Dicer1 biogenesis pathway. PMID: 28740544
  8. TIMP-3 mRNA expression levels positively correlates with levels of miR-21 in in situ breast carcinomas and negatively in progesterone receptor positive invasive breast carcinomas. PMID: 28935174
  9. As a novel CLOCK-dependent diurnal gene, TIMP3 inhibits the expression of inflammatory cytokines that are up-regulated by UV irradiation in human keratinocytes. PMID: 29180440
  10. Preliminary studies indicate that baseline MMP3 and TIMP3 concentrations are associated with patient survival and disease-free time PMID: 29304854
  11. miR-21-5p mediates apoptosis by targeting PTEN and TIMP3. PMID: 29393355
  12. Genetic variation in the TIMP-3 gene may contribute to individual differences in mixture plaque susceptibility in the Han Chinese population. PMID: 29498555
  13. TIMP3 methylation is a marker for TN tumours and furthermore we showed for the first time that TIMP3 promoter methylation is an epigenetic marker of BRCA1ness tumours. PMID: 29524167
++ 37 more research findings link this target to additional biology. Showing the 13 most recent — the full set appears on the complete datasheet.
Involvement in disease
Sorsby fundus dystrophy (SFD)
Subcellular Location
Secreted, extracellular space, extracellular matrix.
Protein Families
Protease inhibitor I35 (TIMP) family
Database Links

HGNC: 11822

OMIM: 136900

KEGG: hsa:7078

STRING: 9606.ENSP00000266085

UniGene: Hs.644633

Precision

Intra-assay Precision (Precision within an assay): CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess.

Inter-assay Precision (Precision between assays): CV%<10%

Three samples of known concentration were tested in twenty assays to assess.

Intra-Assay Precision

Inter-Assay Precision

Sample

1

2

3

1

2

3

n

20

20

20

20

20

20

Mean(pg/ml)

246.660

246.505

242.560

248.749

245.363

251.011

SD

0.038

0.035

0.046

0.034

0.033

0.031

CV(%)

6.221

5.710

7.590

5.574

5.464

5.049

Typical Data

These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.

Human tissue inhibitors of metalloproteinase 3,TIMP-3 ELISA Kit

pg/ml

OD1

OD2

Average

Corrected

2000

2.753

3.081

2.917

2.761

1000

1.636

1.796

1.716

1.560

500

1.030

1.088

1.059

0.903

250

0.541

0.565

0.553

0.397

125

0.390

0.365

0.378

0.222

62.5

0.261

0.247

0.254

0.098

31.25

0.202

0.215

0.209

0.053

0

0.154

0.157

0.156

Linearity

To assess the linearity of the assay, samples were spiked with high concentrations of human TIMP-3 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.

Sample

Serum(n=4)

1:4

Average %

91

Range %

87-98

1:8

Average %

90

Range %

85-94

1:16

Average %

92

Range %

88-93

1:32

Average %

96

Range %

89-98

Recovery

The recovery of human TIMP-3 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.

Sample Type

Average % Recovery

Range%

Serum (n=5)

91

87-94

EDTA plasma (n=4)

95

88-97

Peer-reviewed citations
++ 1 more peer-reviewed citations feature this kit. Showing the 1 most recent — browse every publication on the full product page.

Satisfaction
Quality Rating
Value Rating
Style Rating
X