/Content/Upload/Product/Human_ELISA_kits_Diagnocine_1200_1200(105).jpg

Human Hepatitis E virus antibody(IgG)ELISA Kit

Product#: CS-CSB-E04811h
$626.80
Availability:
Ships in 24 hours

The Ultimate 1-Stop ELISA Marketplace:

60,000+ ELISA kits Available to Serve Scientists from All Fields of Life Science

Always Powered by Diagnocine for Precision Research.

 
Made In-USA · ISO 13485 Certified 

Most comprehensive buffers, reagents and detection agents are provided with each kit to optimize data output.  
All-inclusive format covers everything from sample preparation to signal detection.  Every step can be customized and optimized for your precision research.
DiagnoCine Precision buffers and reagents are Made in USA ISO 13485 Certified

One Stop Purchasing but Zero Compromise on Accuracy

Why waste time searching for your ELISA kit when you can get everything in one place? Diagnocine can provide you with all the ELISA needs you have (customized ELISAs also available) on the planet through a single, streamlined ordering process.  
* all types of species
* HRP and AP detection
* Low target signal enhancement
* Inquire about a trial version or a customized version

Low Signal Optimization Reagents

4 core reagents below are included with every order, plus 1 of the 2 detection-specific reagents (matched automatically to your kit type) — 5 components, every time.

DCP-PIC100X

Protease Inhibitor Cocktail (100X)

Included with every order
 DCP-SM1AbTBS1X

SigMax 1Ab-TBS

Included with every order
 DCP-UTBS1X

Universal Blocking Buffer

Included with every order
 DCP-SM2AbTBS1X

SigMax 2Ab-TBS

Included with every order

+ the 5th component, matched to your kit's detection method:

DCP-HRPTBS1X

HRPQuench-TBS

Exclusively for HRP-based kits
OR
DCP-ALPTBS1X

ALPQuench-TBS

Exclusively for ALP-based kits

If you have any questions or need additional information, please call us at 551-245-1033 or email us at support@diagnocine.com. Our team will be happy to assist you.

Key Value Highlights

Universal Compatibility

All buffers and detection reagents work seamlessly across target proteins, bridging the gap in assay consistency.

1-Stop Convenience

Consolidate your lab's purchasing. Source all ELISA needs and experience optimal buffers and reagents in a single shipment.

Enhanced Precision

Designed by scientists for scientists,  all components are engineered to deliver sharper results and an optical signal.

Human ELISA Kit · Microbiology

Human Hepatitis E virus antibody(IgG)ELISA Kit

Indirect quantitative immunoassay for Hepatitis E virus antibody(IgG) in human serum, plasma  available in multiple catalog sizes:

Trial 24T 96T

Note: Please send inquiries regarding Trial 24T orders to support@diagnocine.com.

Detection Range
Request Information
Sensitivity
Request Information
Assay Time
1-5 hours
Sample Volume
50-100 μL
Product specifications
Target nameHepatitis E virus antibody(IgG)
SpeciesHomo sapiens (Human)
Sample typesserum, plasma
Detection rangeRequest Information
SensitivityRequest Information
Assay time1-5h
Sample loading volume50-100μL
Detection wavelength450 nm
Assay principleIndirect (Quantitative)
Data analysisStandard curve + Curve Expert software
Research areaMicrobiology
Storage condition2-8°C (see protocol for full details)
Shipping condition4 °C
Shelf life6 months
Hepatitis E virus antibody(IgG) serum plasma Microbiology Human ELISA
Lead Time

10 business days

Processing + 3-5 days shipping

Availability

In Stock : USA

Worldwide shipping available

Assay principle
Sample prep
Immunoreaction
450 nm detection
Standard curve
Quantification

Quantification uses a standard curve fitted with Curve Expert software, covering Request Information with a minimum detectable dose of Request Information.

For research use only (RUO). Not intended for diagnostic or therapeutic purposes. Validated in human serum, plasma matrices only.
Description

This Human Hepatitis E virus antibody (IgG) ELISA Kit is designed to qualitatively detect the HEV IgG antibody in the serum and plasma. It employs the qualitative enzyme immunoassay technique. The microtiter plate has been pre-coated with HEV antigen. Samples or standards are pipetted into the wells with anti-human IgG conjugated HRP. Following a wash to remove any unbound reagent, the TMB substrate solution is added to the wells and color develops in proportion to the amount of human HEV IgG antibody bound in the initial step. The color development is stopped and the intensity of the color is measured by a microplate reader at 450 nm.The valence of human HEV IgG antibody in the samples is determined by referring to the negative control. It indicates the presence of HEV IgG antibody if the O.D. (optical density) of sample is greater than or equal to the cutoff value (average Negative Control O.D. value plus 0.10). There is no HEV IgG antibody present in the sample if the O.D. is less than the cutoff value. This assay has high sensitivity and excellent specificity for detection of human HEV IgG antibody. And it also has been validated with precision less than 15% and lot-to-lot consistency. Get more details from the product instructions. HEV is a small, non-enveloped RNA virus that causes an acute, self-limited infection. Both anti-HEV IgM and IgG antibodies are produced after infection. Infected patients develop hepatitis symptoms following an incubation period of 15 to 60 days. Anti-HEV IgM antibodies appear in their serum at this time, followed by detectable anti-HEV IgG within a few days. HEV IgM antibody can still be detected 6 months after the onset of symptoms, while anti-HEV IgG usually persists for many years after infection. Anti-HEV IgG serological test can determine previous exposure to HEV. A positive result indicates prior or resolved HEV infection. A negative result indicates no past exposure to HEV.

Precision

Intra-assay Precision (Precision within an assay): CV%<15%

Three samples of known concentration were tested twenty times on one plate to assess.

Inter-assay Precision (Precision between assays): CV%<15%

Three samples of known concentration were tested in twenty assays to assess.

Typical Data

Test parameter

specification

test result

Positive control

>0.30

0.799

Negative control

<0.08

0.046

Positive rate

10,Positive

100%

Negative rate

10,Negative

100%

Materials provided
  • A 96-well Assay plate --The 96-well plate has been pre-coated with HEV antigen
  • Negative Control (1 x 0.4ml) --Eliminate false positive
  • Positive Control (1 x 0.4ml) --Used to evaluate the validity, stability, and comparability of experimental results.
  • HRP-conjugated IgG antibody(1 x 12ml) --Bind to the anti-HEV IgG antibody, and HRP catalyzes the TMB to elicit a chromogenic reaction.
  • Sample Diluent (1x 12ml) --Dilute the sample to an appropriate concentration.
  • Wash Buffer (20x concentrate) (1 x 50 ml) --Wash away unbound or free substances.
  • Substrate A (1 x 6ml) --Mix with substrate B and interact with HRP, eliciting a Chromogenic reaction.
  • Substrate B (1 x 6ml) --Mix with substrate A and interact with HRP, eliciting a Chromogenic reaction.
  • Stop Solution (1 x 6ml) --Stop the color reaction. The solution color immediately turns from blue to yellow.
  • Four Adhesive Strips (For 96 wells)--Cover the microplate when incubation.
  • An Instruction manual
Materials not provided
  • A microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 630 nm.
  • An incubator that can provide stable incubation conditions up to 37°C±5°C.
  • Centrifuge
  • Vortex
  • Squirt bottle, manifold dispenser, or automated microplate washer
  • Absorbent paper for blotting the microtiter plate
  • 50-300ul multi-channel micropipette
  • Pipette tips
  • Single-channel micropipette with different ranges
  • 100ml and 500ml graduated cylinders
  • Deionized or distilled water
  • Timer
  • Test tubes for dilution

Satisfaction
Quality Rating
Value Rating
Style Rating
X