The Ultimate 1-Stop ELISA Marketplace:
60,000+ ELISA kits Available to Serve Scientists from All Fields of Life Science
Always Powered by Diagnocine for Precision Research.
Most comprehensive buffers, reagents and detection agents are provided with each kit to optimize data output.
All-inclusive format covers everything from sample preparation to signal detection. Every step can be customized and optimized for your precision research.
DiagnoCine Precision buffers and reagents are Made in USA ISO 13485 Certified
Why waste time searching for your ELISA kit when you can get everything in one place? Diagnocine can provide you with all the ELISA needs you have (customized ELISAs also available) on the planet through a single, streamlined ordering process.
* all types of species
* HRP and AP detection
* Low target signal enhancement
* Inquire about a trial version or a customized version
4 core reagents below are included with every order, plus 1 of the 2 detection-specific reagents (matched automatically to your kit type) — 5 components, every time.
+ the 5th component, matched to your kit's detection method:
If you have any questions or need additional information, please call us at 551-245-1033 or email us at support@diagnocine.com. Our team will be happy to assist you.
Universal Compatibility
All buffers and detection reagents work seamlessly across target proteins, bridging the gap in assay consistency.
1-Stop Convenience
Consolidate your lab's purchasing. Source all ELISA needs and experience optimal buffers and reagents in a single shipment.
Enhanced Precision
Designed by scientists for scientists, all components are engineered to deliver sharper results and an optical signal.
Human Hepatitis E virus antibody(IgG)ELISA Kit
Indirect quantitative immunoassay for Hepatitis E virus antibody(IgG) in human serum, plasma available in multiple catalog sizes:
Note: Please send inquiries regarding Trial 24T orders to support@diagnocine.com.
| Target name | Hepatitis E virus antibody(IgG) |
| Species | Homo sapiens (Human) |
| Sample types | serum, plasma |
| Detection range | Request Information |
| Sensitivity | Request Information |
| Assay time | 1-5h |
| Sample loading volume | 50-100μL |
| Detection wavelength | 450 nm |
| Assay principle | Indirect (Quantitative) |
| Data analysis | Standard curve + Curve Expert software |
| Research area | Microbiology |
| Storage condition | 2-8°C (see protocol for full details) |
| Shipping condition | 4 °C |
| Shelf life | 6 months |
10 business days
Processing + 3-5 days shipping
In Stock : USA
Worldwide shipping available
Immunoreaction
450 nm detection
Standard curve
Quantification
Quantification uses a standard curve fitted with Curve Expert software, covering Request Information with a minimum detectable dose of Request Information.
This Human Hepatitis E virus antibody (IgG) ELISA Kit is designed to qualitatively detect the HEV IgG antibody in the serum and plasma. It employs the qualitative enzyme immunoassay technique. The microtiter plate has been pre-coated with HEV antigen. Samples or standards are pipetted into the wells with anti-human IgG conjugated HRP. Following a wash to remove any unbound reagent, the TMB substrate solution is added to the wells and color develops in proportion to the amount of human HEV IgG antibody bound in the initial step. The color development is stopped and the intensity of the color is measured by a microplate reader at 450 nm.The valence of human HEV IgG antibody in the samples is determined by referring to the negative control. It indicates the presence of HEV IgG antibody if the O.D. (optical density) of sample is greater than or equal to the cutoff value (average Negative Control O.D. value plus 0.10). There is no HEV IgG antibody present in the sample if the O.D. is less than the cutoff value. This assay has high sensitivity and excellent specificity for detection of human HEV IgG antibody. And it also has been validated with precision less than 15% and lot-to-lot consistency. Get more details from the product instructions. HEV is a small, non-enveloped RNA virus that causes an acute, self-limited infection. Both anti-HEV IgM and IgG antibodies are produced after infection. Infected patients develop hepatitis symptoms following an incubation period of 15 to 60 days. Anti-HEV IgM antibodies appear in their serum at this time, followed by detectable anti-HEV IgG within a few days. HEV IgM antibody can still be detected 6 months after the onset of symptoms, while anti-HEV IgG usually persists for many years after infection. Anti-HEV IgG serological test can determine previous exposure to HEV. A positive result indicates prior or resolved HEV infection. A negative result indicates no past exposure to HEV.
Intra-assay Precision (Precision within an assay): CV%<15% | |||||||||
Three samples of known concentration were tested twenty times on one plate to assess. | |||||||||
Inter-assay Precision (Precision between assays): CV%<15% | |||||||||
Three samples of known concentration were tested in twenty assays to assess. | |||||||||
Test parameter | specification | test result | |||||
Positive control | >0.30 | 0.799 | |||||
Negative control | <0.08 | 0.046 | |||||
Positive rate | 10,Positive | 100% | |||||
Negative rate | 10,Negative | 100% | |||||
- A 96-well Assay plate --The 96-well plate has been pre-coated with HEV antigen
- Negative Control (1 x 0.4ml) --Eliminate false positive
- Positive Control (1 x 0.4ml) --Used to evaluate the validity, stability, and comparability of experimental results.
- HRP-conjugated IgG antibody(1 x 12ml) --Bind to the anti-HEV IgG antibody, and HRP catalyzes the TMB to elicit a chromogenic reaction.
- Sample Diluent (1x 12ml) --Dilute the sample to an appropriate concentration.
- Wash Buffer (20x concentrate) (1 x 50 ml) --Wash away unbound or free substances.
- Substrate A (1 x 6ml) --Mix with substrate B and interact with HRP, eliciting a Chromogenic reaction.
- Substrate B (1 x 6ml) --Mix with substrate A and interact with HRP, eliciting a Chromogenic reaction.
- Stop Solution (1 x 6ml) --Stop the color reaction. The solution color immediately turns from blue to yellow.
- Four Adhesive Strips (For 96 wells)--Cover the microplate when incubation.
- An Instruction manual
- A microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 630 nm.
- An incubator that can provide stable incubation conditions up to 37°C±5°C.
- Centrifuge
- Vortex
- Squirt bottle, manifold dispenser, or automated microplate washer
- Absorbent paper for blotting the microtiter plate
- 50-300ul multi-channel micropipette
- Pipette tips
- Single-channel micropipette with different ranges
- 100ml and 500ml graduated cylinders
- Deionized or distilled water
- Timer
- Test tubes for dilution
Human Hepatitis E virus antibody(IgG)ELISA Kit | For research use only | Store 2-8°C | Diagnocine