10% Neutral Buffered Formalin

Product#: DCP-NBF4X
$61.60
Availability:
Ships in 24 hours

Fixative Buffer
ISO 13485 Certified Manufacturing

FluxMPS™ 10% Neutral Buffered Formalin

FluxMPS™ 10% Neutral Buffered Formalin is an ultrapure, ready-to-use histology fixative buffered to pH 7.4 with approximately 4% formaldehyde. Processed through a quadruple-stage 0.1 µm and 0.04 µm membrane architecture and verified free of detectable DNase and RNase activity, it delivers gold-standard, artifact-free tissue preservation for diagnostic and research laboratories, including those handling organ-on-a-chip and microphysiological system specimens.

  • Quadruple-stage filtration: 0.1 µm membrane (twice) and 0.04 µm membrane (twice)
  • Neutral buffered to pH 7.4 for artifact-free tissue morphology
  • Approximately 4% formaldehyde, ready-to-use formulation
  • No detectable DNase or RNase activity
  • Manufactured under ISO 13485-certified, CE-approved quality systems
  • 24-month shelf life at room temperature
  • Suitable for organ-on-a-chip and microphysiological system histological endpoint fixation
  • Custom concentrations, additives, and pH available on request
SKU: DCP-NBF4X | 12161703 Fixative Buffers
10% Neutral Buffered Formalin – 500 mL
  • Formulation~4% Formaldehyde, Neutral Buffered
  • pH7.4
  • Filtration0.1 µm x2 + 0.04 µm x2
  • DNase ActivityNone Detected
  • RNase ActivityNone Detected
  • AppearanceClear Solution
  • StorageRoom Temperature, Protected from Light
  • Shelf Life24 Months
  • Fixative Ratio10:1 (Minimum)
  • Fixation Time6-24 Hours
ISO 13485:2016 USP <85> <785> <788> RUO
Why FluxMPS™

Engineered where standard fixatives fall short

Conventional 0.22 µm-filtered buffered formalin can carry subvisible particulates, unverified nuclease background, and inconsistent buffering that compromises nuclear detail and downstream molecular work. FluxMPS™ NBF is built to eliminate those failure modes.

filter_alt

Microchannel-Safe Purity

Quadruple-stage 0.1 µm and 0.04 µm membrane filtration removes particulate and aggregate contamination before final fill.

target

Precise, Stable pH

Buffered to pH 7.4 with a sodium phosphate monobasic/dibasic system that prevents autolysis and fixation artifacts.

water_drop

Ultrapure-Grade Water

Formulated with Ultrapure Type 1 water (18.2 MΩ·cm), aligned with USP <85> quality practice.

visibility

Clean, Artifact-Free Preservation

Verified free of detectable DNase and RNase activity for reliable downstream molecular and IHC workflows.

science

Defined, Traceable Composition

A three-component buffered formalin formulation with lot-controlled ingredient concentrations.

tune

Customization on Demand

Concentration, pH, and additive modifications available upon inquiry to support@diagnocine.com.

Purity Architecture

Quadruple-stage filtration system

10% Neutral Buffered Formalin is filtered 0.1-micron membrane twice and 0.04-micron membrane twice, combining redundant coarse pre-filtration with a final sub-0.1 µm polish for microchannel-safe, low-particulate fixative buffer.

  1. 1

    0.1 µm Pre-filtration I

    Large particulate and aggregate removal from the formaldehyde-based buffer, extending downstream filter life.

  2. 2

    0.04 µm Pre-filtration II

    Fine particulate and bioburden retention ahead of final processing.

  3. 3

    0.1 µm Sterile-filtration I

    Second-pass 0.1 µm redundancy prior to final polishing.

  4. 4

    0.04 µm Sterile-filtration II — Final Polish

    Ultimate 0.04 µm polish performed under ISO Class 5 (Class 100) conditions. This combination of two 0.1 µm passes and two 0.04 µm passes is designed to exclude contaminants, including mycoplasma — the smallest of which measure about 0.2 microns.

Performance vs. conventional buffer

Sequential 0.1 µm and 0.04 µm filtration passes remove finer particulates than a single conventional 0.22 µm filtration pass typically used for standard buffered formalin, reducing background interference in downstream molecular and imaging workflows.

0.04 µm
Final filtration stage
4
Total filtration stages
Manufactured under ISO 13485-certified, CE-approved quality systems at supplier facilities, with final packaging, quality assurance, and customization completed at the DiagnoCine R&D and Quality Testing Center in Totowa, New Jersey, USA.
DCP-NBF4X FluxMPS 10% Neutral Buffered Formalin quadruple-stage 0.1 micron and 0.04 micron filtration diagram for organ-on-a-chip, microfluidic, and histology applications by Diagnocine
Figure 1. Quadruple-stage filtration architecture — 0.1-micron membrane twice and 0.04-micron membrane twice — applied to FluxMPS™ 10% Neutral Buffered Formalin.
© Diagnocine® — DCP-NBF4X
Applications

Where 10% Neutral Buffered Formalin is used

A ready-to-use, gold-standard fixative for histopathology laboratories worldwide, supporting both routine diagnostic work and advanced research applications.

Automated Bioreactors & Robotics

Next-Generation System Uptime

Automated tissue processors and robotic liquid handlers used in high-throughput histology laboratories benefit from ultra-clean, low-particulate fixative. An optional 0.01 µm (10 nm) ultra-filtered variant is available for the most sensitive automated systems.

  • Total Particulate Exclusion for automated processing lines
  • Valve & Sensor Protection in robotic liquid-handling systems
  • Extended Perfusion Stability for continuous-fill processing equipment

Inquiry Required: please inquire if the 0.01 µm (10 nm) ultra-filtered variant, other concentrations, additional chemicals, or a different pH is needed — contact support@diagnocine.com.

Microfluidics

Organ-on-a-Chip Tissue Fixation

Histological endpoint fixation of tissue harvested from microphysiological and organ-on-a-chip platforms.

OoCToCBoCMPS
Histopathology

Routine Diagnostic Tissue Fixation

Routine histological tissue fixation in diagnostic settings and preparation of samples for light microscopy.

Light MicroscopyDiagnostic Histology
Immunohistochemistry

IHC & Antigen Retrieval Workflows

Immunohistochemistry procedures with appropriate antigen retrieval.

IHCIFAntigen Retrieval
Specimen Preservation

Long-Term Museum Specimen Preservation

Permits restoration of natural color and long-term preservation of museum specimens.

Museum SpecimensArchival
Research

Morphological Preservation for Research

Research applications requiring consistent morphological preservation of cellular constituents.

ResearchCross-linking
Sample Preparation

Tissue Processing & Embedding Prep

Standard fixative-to-tissue processing ahead of embedding and sectioning in high-throughput labs.

ProcessingEmbedding
Technical Specifications

Detailed product specifications

Physical, chemical, purity, storage, and traceability parameters for DCP-NBF4X.

Physical & Chemical Parameters
Parameter Specification
Formulation / Composition 10% Neutral Buffered Formalin, approximately 4% formaldehyde
Appearance Clear solution
pH USP <791> 7.4
Formaldehyde (40% stock) 100 mL/L
Sodium phosphate, monobasic (NaH2PO4·H2O) 4.0 g/L
Sodium phosphate, dibasic (Na2HPO4) 6.5 g/L
Sterility, Purity & Safety Parameters
Parameter Specification
Sterility (Filtration-Based) 0.1 µm membrane (twice) and 0.04 µm membrane (twice)
DNase Activity None detected (18 hours, room temperature)
RNase Activity None detected (18 hours, room temperature)
Water Quality Ultrapure Type 1 water (18.2 MΩ·cm)
Fill Environment ISO Class 5 ISO Class 5 (Class 100)
Manufacturing Standard ISO 13485 ISO 13485-certified, CE-approved
Storage, Handling & Logistics
Parameter Specification
Storage Temperature Room temperature, away from bright light
Shelf Life 24 months
Fixative-to-Tissue Ratio 10:1 (minimum)
Routine Fixation Time 6-24 hours (larger specimens may require longer fixation times)
Raw Materials & Regulatory Traceability
Parameter Specification
Manufacturing QMS ISO 13485-certified supplier facilities (DiagnoCine Precision)
Regulatory Alignment CE-approved
Production & Customization Site DiagnoCine R&D and Quality Testing Center, Totowa, New Jersey, USA
Intended Use Research Use Only (RUO); histopathology, IHC, museum specimen preservation, research
Formulation

Full composition

10% Neutral Buffered Formalin is a defined, three-component buffered formalin formulation released per lot.

Component CAS Number Concentration
Formaldehyde (40%) 50-00-0 100 mL/L
Sodium phosphate, monobasic (NaH2PO4·H2O) 10049-21-5 4.0 g/L
Sodium phosphate, dibasic (Na2HPO4) 7558-79-4 6.5 g/L
Custom concentrations, additional chemicals, compounds, proteins, supplements, or a different pH can be formulated on request — contact support@diagnocine.com.
Quality Assurance

Manufacturing & compliance

Manufactured under ISO 13485-certified, CE-approved supplier facilities, with final packaging, QA, and customization completed at the DiagnoCine R&D and Quality Testing Center.

verified

ISO 13485:2016 Quality System

Manufactured under ISO 13485-certified and CE-approved supplier facilities.

water_drop

Ultrapure Type 1 Water

Formulated with 18.2 MΩ·cm Type 1 water to support a low-background fixative buffer.

biotech

Quadruple-Stage Filtration

0.1 µm membrane (twice) and 0.04 µm membrane (twice) processing performed under ISO Class 5 (Class 100) conditions.

assignment

Nuclease-Verified Micro-Batch QC

Each batch verified free of detectable DNase and RNase activity after 18-hour incubation at room temperature.

Sterility via Quadruple-Stage Filtration

0.1 µm membrane (twice) and 0.04 µm membrane (twice) filtration designed to exclude contaminants including mycoplasma.

CE-Approved Manufacturing

Produced under CE-approved supplier facilities alongside ISO 13485-certified quality systems.

Nuclease-Free Verification (DNase/RNase)

No DNase or RNase activity detected after 18-hour incubation with plasmid DNA or ribosomal RNA at room temperature.

Documentation / Certificate of Analysis

Lot-specific documentation covering composition, pH, filtration, and nuclease testing.

A Certificate of Analysis (CoA) is available for this lot — contact support@diagnocine.com.
Product Comparison

How DCP-NBF4X compares

FluxMPS™ DCP-NBF4X against conventional buffered formalin filtration architectures.

Parameter DCP-NBF4X (FluxMPS™) Conventional Buffered Formalin Standard Alternative
Filtration Architecture 0.1 µm (twice) + 0.04 µm (twice) Single 0.22 µm pass Single 0.22 µm pass
Final Filtration Pore Size 0.04 µm 0.22 µm 0.22 µm
Number of Filtration Stages 4 1 1
Neutral Buffered pH check_circle 7.4 cancel Variable cancel Variable
Nuclease Testing (DNase/RNase) check_circle cancel cancel
ISO 13485 / CE Manufacturing check_circle cancel cancel
Custom Formulation Available check_circle cancel cancel
Museum/Archival Specimen Suitability check_circle cancel cancel
FAQ

Frequently asked questions

Common questions about DCP-NBF4X 10% Neutral Buffered Formalin.

DCP-NBF4X is a general histology fixative and is well suited for fixing tissue specimens harvested from organ-on-a-chip and microphysiological system platforms for downstream histological endpoint analysis, including light microscopy and immunohistochemistry.
DCP-NBF4X is filtered through a 0.1-micron membrane twice and a 0.04-micron membrane twice, a quadruple-stage sequence that removes finer particulate than a single conventional 0.22 µm pass and is designed to exclude contaminants including mycoplasma, the smallest of which measure about 0.2 microns.
DCP-NBF4X is buffered to pH 7.4 with approximately 4% formaldehyde and a sodium phosphate monobasic/dibasic system. Other concentrations, additional chemicals, compounds, proteins, supplements, or a different pH can be formulated on request — contact support@diagnocine.com.
The product is specified at pH 7.4. It should be stored at room temperature away from bright light, with a shelf life of 24 months; use before the expiry date on the product label.
Yes. Please inquire if other concentrations, additions of chemicals, compounds, proteins, or supplements, a different pH, or other modifications are needed — contact support@diagnocine.com.
Endotoxin testing is not part of this product's standard release panel. Instead, each lot is verified free of detectable DNase and RNase activity after 18-hour incubation with plasmid DNA and ribosomal RNA at room temperature, alongside the quadruple-stage 0.1/0.04 µm filtration used to control bioburden.
Yes, a lot-specific CoA is available covering composition, pH, appearance, filtration, and DNase/RNase testing results — contact support@diagnocine.com.
Scientific References

Supporting literature

Curated references on formalin fixation chemistry, histology, and organ-on-a-chip workflows.

  1. Fox CH, Johnson FB, Whiting J, Roller PP. Formaldehyde fixation. J Histochem Cytochem. 1985. doi:10.1177/33.8.3894502
  2. Werner M, Chott A, Fabiano A, Battifora H. Effect of formalin tissue fixation and processing on immunohistochemistry. Am J Surg Pathol. 2000. doi:10.1097/00000478-200007000-00014
  3. Thavarajah R, Mudimbaimannar VK, Elizabeth J, Rao UK, Ranganathan K. Chemical and physical basics of routine formaldehyde fixation. J Oral Maxillofac Pathol. 2012. doi:10.4103/0973-029X.102496
  4. Srinivasan M, Sedmak D, Jewell S. Effect of fixatives and tissue processing on the content and integrity of nucleic acids. Am J Pathol. 2002. doi:10.1016/S0002-9440(10)64920-1
  5. Ingber DE. Reverse engineering human pathophysiology with organs-on-chips. Cell. 2016. doi:10.1016/j.cell.2016.05.048
  6. Low LA, Mummery C, Berridge BR, Austin CP, Tagle DA. Organs-on-chips: into the next decade. Nat Rev Drug Discov. 2021. doi:10.1038/s41573-020-0079-3
  7. Chatterjee S. Artefacts in histopathology. J Oral Maxillofac Pathol. 2014. doi:10.4103/0973-029X.141346
  8. Titford M. The long history of formaldehyde in histology and pathology. Biotech Histochem. 2009. doi:10.1080/10520290903039052