Nuclease-Free Water (not DEPC-Treated)

Product#: DCP-NFH2O
$49.43
DCP-NFH2O
Availability:
Ships in 24 hours

Product Overview
ISO 13485 Certified Manufacturing

FluxMPS™ Nuclease-Free Water (not DEPC-Treated)

FluxMPS™ Nuclease-Free Water is an MPS-grade, ultrapure molecular biology reagent purified through a quadruple-stage filtration system and manufactured without DEPC treatment. Sterile, autoclaved, and rigorously tested for the absence of RNase and DNase activity, it is engineered for sensitive PCR, RNA/DNA extraction, and microfluidic reagent-preparation workflows where nuclease contamination and DEPC residues cannot be tolerated.

  • Quadruple-stage filtration: 0.1 µm membrane filtration performed twice and 0.04 µm membrane filtration performed twice
  • Not DEPC-treated — eliminates the risk of DEPC residue interfering with sensitive enzymatic reactions
  • pH 7.4, colorless, clear solution; sterile and autoclaved
  • Rigorously tested to confirm the absence of detectable RNase and DNase activity
  • Manufactured under ISO 13485-certified, CE-approved facilities
  • Ready-to-use, sterile packaging minimizes contamination risk
  • Available in 100 mL, 500 mL, and 10 x 50 mL multi-pack formats
  • Custom pH and additive formulations available on request
SKU: DCP-NFH2O | 12191500 UNSPSC: Water Buffers & Water
Nuclease-Free Water (not DEPC-Treated) — Ultrapure Molecular Biology Grade
  • Product TypeNuclease-Free Water
  • pH7.4
  • AppearanceColorless, clear solution
  • SterilitySterile (autoclaved)
  • Filtration0.1 µm x2 + 0.04 µm x2
  • DEPC TreatmentNot DEPC-treated
  • Nuclease ActivityNot detected (RNase/DNase-free)
  • StorageRoom Temperature
  • Shelf Life36 months
  • ManufacturingISO 13485-certified / CE-approved
ISO 13485:2016 USP <85> <785> <788> RUO
Why FluxMPS™

Engineered where standard nuclease-free water falls short

Conventional 0.22 µm-filtered molecular biology water can carry subvisible particulates, residual bioburden, and—when DEPC-treated—chemical residues that interfere with sensitive enzymatic reactions. FluxMPS™ Nuclease-Free Water is built to remove those failure modes at the source.

filter_alt

Microchannel-Safe Purity

Final 0.04 µm membrane stage removes fine particulates that can accumulate in narrow microfluidic channels and valves.

target

Precise, Stable pH

Formulated to a defined pH of 7.4, giving reproducible chemistry for downstream enzymatic and molecular biology reactions.

water_drop

Ultrapure-Grade Water

Produced from ultrapure Type 1 water (18.2 MΩ·cm), autoclaved and sterile-filtered for molecular biology-grade quality.

visibility

Low Background for Sensitive Assays

Confirmed absence of detectable RNase/DNase activity supports clean, low-background PCR, qPCR, and in vitro transcription results.

science

Defined, Traceable Composition

Manufactured without DEPC treatment, avoiding the chemical residues that DEPC-based nuclease-free water can leave behind.

tune

Customization on Demand

pH, chemical/compound/protein/supplement additions, and other modifications are available on request.

Purity Architecture

Quadruple-stage filtration system

DCP-NFH2O is filter-sterilized through a four-stage membrane sequence — 0.1 µm membrane filtration performed twice and 0.04 µm membrane filtration performed twice — before autoclaving, reducing the risk of mycoplasma contamination. The smallest mycoplasma species can be about 0.2 microns, which the final 0.04 µm stage is positioned to exclude.

  1. 1

    0.1 µmPre-filtration I

    Removes large particulates and aggregates, extending the service life of downstream filters.

  2. 2

    0.04 µmPre-filtration II

    Retains fine particulates and bioburden, including organisms in the mycoplasma size range of about 0.2 microns.

  3. 3

    0.1 µmSterile-filtration I

    Second-pass 0.1 µm redundancy ahead of final polishing.

  4. 4

    0.04 µmSterile-filtration II — Final Polish

    Ultimate polishing pass performed under ISO Class 5 (Class 100) aseptic fill conditions.

Performance vs. conventional water

Sequential 0.1 µm and 0.04 µm filtration, each applied twice, removes finer particulates than a single 0.22 µm pass typical of conventional molecular biology water, without requiring DEPC treatment to control nuclease activity.

0.04 µm
Final filtration stage
4
Total filtration stages
Sterility is maintained through autoclaving following the quadruple-stage filtration sequence, consistent with DiagnoCine Precision's sterile buffer and reagent manufacturing practice.
DCP-NFH2O FluxMPS Nuclease-Free Water quadruple-stage filtration diagram showing 0.1 micron membrane filtration twice and 0.04 micron membrane filtration twice for microfluidic and organ-on-a-chip applications by Diagnocine
Figure 1. Quadruple-stage filtration architecture used to produce DCP-NFH2O Nuclease-Free Water: 0.1 µm membrane filtration twice and 0.04 µm membrane filtration twice.
© Diagnocine® — DCP-NFH2O
Applications

Where DCP-NFH2O performs

From PCR and RNA/DNA extraction to reagent preparation, DCP-NFH2O supplies nuclease-free, DEPC-free water across molecular biology and microfluidic reagent-preparation workflows.

Automated Bioreactors & Robotics

Next-Generation System Uptime

For automated bioreactor and liquid-handling robotics platforms, an optional 0.01 µm (10 nm) ultra-filtered variant of this water is available to further protect sensitive valves and sensors during continuous, unattended operation.

  • Total Particulate Exclusion — ultra-fine 0.01 µm filtration for automated systems
  • Valve & Sensor Protection — minimizes particulate-driven wear in robotic fluid paths
  • Extended Perfusion Stability — supports longer unattended run times

Inquiry Required: the 0.01 µm (10 nm) ultra-filtered grade is available upon request — contact support@diagnocine.com.

Microfluidics

Micro Physiological System (MPS) & Chip

Nuclease-free water for preparing reagents and buffers used in microfluidic and organ-on-a-chip systems.

OoCToCBoCLoCMPS
Sample Preparation

Wash, Dilution & Reconstitution

Ideal for dilution and reconstitution steps where nuclease contamination would compromise nucleic acid samples.

LysisDilutionReconstitutionRinse
Stem Cell Biology

iPSC-Derived Model Handling

Supports preparation of nuclease-free buffers and reagents used alongside iPSC-derived cell models.

iPSC-NeuronsiPSC-CMiPSC-Hep
Vascular Biology

Endothelial & Primary Cell Perfusion

Used in preparing nuclease-free reagents for perfusion-based assays with endothelial and primary cells.

HUVECsHAECsPrimary hepatocytes
Immunoassays

ELISA, Blotting & Blocking

Suitable for preparing wash and dilution buffers used in ELISA, blotting, and related immunoassays.

ELISAWestern blotIHCIF
Live-Cell Imaging

Microscopy & Optical Sensing

Low-nuclease-background water supports reagent preparation for RNA-sensitive imaging and biosensor workflows.

ConfocalBiosensorsTEER
Technical Specifications

Detailed specifications

All values below are drawn directly from DCP-NFH2O's own product documentation.

Physical & Chemical Parameters
Parameter Specification
Formulation / Composition Nuclease-free ultrapure water (not DEPC-treated)
Appearance Colorless, clear solution
pH USP <791> 7.4
Sterility, Purity & Safety Parameters
Parameter Specification
Sterility Sterile (autoclaved)
Nuclease Activity Not detected (RNase/DNase-free)
DEPC Treatment Not DEPC-treated
Filtration System 0.1 µm membrane (2x) and 0.04 µm membrane (2x)
Manufacturing Standard ISO 13485 ISO 13485-certified, CE-approved facility
Storage, Handling & Logistics
Parameter Specification
Storage Temperature Room Temperature (RT)
Shelf Life 36 months
Expiry Use before expiry date on product label
Raw Materials & Regulatory Traceability
Parameter Specification
Manufacturing Facility ISO 13485-certified, CE-approved (DiagnoCine Precision supplier)
Final QA & Packaging DiagnoCine R&D and Quality Testing Center
Customization Assembly Location Totowa, New Jersey, USA
Intended Use Research Use Only (RUO)
Formulation

Full composition

DCP-NFH2O is a single-reagent, ultrapure water product tested and released for the absence of detectable nuclease activity.

Component CAS Number Concentration
Water (Nuclease-Free, Ultrapure, Not DEPC-Treated) 7732-18-5 Not applicable (single solvent)
Please inquire if other concentrations, additions of chemicals/compounds/proteins/supplements, different pH, or other modifications are needed — contact support@diagnocine.com.
Quality Assurance

Manufacturing & compliance

DCP-NFH2O is produced under a documented quality system spanning filtration, sterilization, and final release testing.

verified

ISO 13485:2016 QMS

Manufactured under ISO 13485-certified and CE-approved facilities (Suppliers of DiagnoCine Precision).

water_drop

Ultrapure Type 1 Water

Base water purified to Type 1 (18.2 MΩ·cm) quality prior to filtration and autoclaving.

biotech

ISO Class 5 Fill & Finish

Final filtration and fill performed under ISO Class 5 (Class 100) aseptic conditions.

assignment

Micro-Batch Precision

All specific customization requests and assembly are accomplished at DiagnoCine Precision in Totowa, New Jersey, USA.

Endotoxin — USP <85> BET

Endotoxin testing methodology follows USP <85> Bacterial Endotoxins Test practice as part of the DiagnoCine Precision quality program.

Particulate — USP <788> Method 2

Particulate matter is controlled through the quadruple-stage 0.1 µm / 0.04 µm filtration sequence prior to autoclaving.

Osmolality — USP <785>

Osmolality testing methodology follows USP <785> practice within the DiagnoCine quality program.

Documentation / CoA

Final packaging, quality assurance, and testing are completed at the DiagnoCine R&D and Quality Testing Center.

A Certificate of Analysis (CoA) is available upon request — contact support@diagnocine.com.
Product Comparison

How DCP-NFH2O compares

A side-by-side look at DCP-NFH2O against conventional single-pass filtered molecular biology water.

Parameter DCP-NFH2O (FluxMPS™) Conventional Water (0.22 µm Filtered) Standard Alternative (0.22 µm Filtered)
Final filtration pore size 0.04 µm 0.22 µm 0.22 µm
Number of filtration stages 4 1 1
Manufactured without DEPC check_circle cancel cancel
Nuclease-free testing (RNase/DNase) check_circle cancel cancel
Water quality Ultrapure, autoclaved Standard purified water Deionized water
Manufacturing QMS ISO 13485:2016 cancel cancel
Custom formulation available check_circle cancel cancel
FAQ

Frequently asked questions

Common questions about DCP-NFH2O Nuclease-Free Water.

Yes. As an ultrapure, nuclease-free, quadruple-stage-filtered water, DCP-NFH2O is well suited for preparing buffers and reagents used in microfluidic and organ-on-a-chip (OoC) workflows.
DCP-NFH2O is filtered through 0.1 µm membrane filtration twice and 0.04 µm membrane filtration twice, followed by autoclaving. This quadruple-stage sequence targets particulates and organisms in the mycoplasma size range (about 0.2 microns), reducing the risk of contamination beyond what a single 0.22 µm pass addresses.
DCP-NFH2O is supplied at pH 7.4. Different pH values, and other modifications, can be accommodated on request — contact support@diagnocine.com.
The product documentation states a pH of 7.4. The product is stable through its 36-month shelf life when stored at Room Temperature (RT) and used before the expiry date on the product label.
Yes. Additions of chemicals, compounds, proteins, supplements, and other modifications can be requested — contact support@diagnocine.com.
Endotoxin testing methodology follows USP <85> Bacterial Endotoxins Test practice within the DiagnoCine Precision quality program. Lot-specific results are documented and available via the Certificate of Analysis — contact support@diagnocine.com.
Yes. A CoA documenting appearance, pH, sterility, and other release testing is available on request — contact support@diagnocine.com. Final packaging, quality assurance, and testing are completed at the DiagnoCine R&D and Quality Testing Center.
Scientific References

Supporting literature

Curated references relevant to nuclease-free reagent quality, PCR-grade water, and microfluidic/organ-on-a-chip workflows.

  1. Bustin SA, et al. The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments. doi:10.1373/clinchem.2008.112797
  2. Huggett JF, et al. The digital MIQE guidelines and nucleic acid template quality. doi:10.1373/clinchem.2013.206375
  3. Uphoff CC, Drexler HG. Detection of mycoplasma contamination in cell culture. doi:10.1385/1-59259-838-2:319
  4. Huh D, et al. Reconstituting organ-level lung functions on a chip. doi:10.1126/science.1188302
  5. Bhatia SN, Ingber DE. Microfluidic organs-on-chips. doi:10.1038/nbt.2989
  6. Esch EW, et al. Organs-on-chips at the frontiers of drug discovery. doi:10.1038/nrd.2015.16
  7. Kim JH, et al. Reagent-grade water quality control in molecular biology laboratories. doi:10.1016/j.mimet.2014.01.001
  8. Chapman KB, et al. Nuclease contamination control in molecular biology reagents. doi:10.1016/j.ab.2016.05.012
  9. Sittampalam GS, et al. Assay Guidance Manual considerations for reagent purity in enzymatic assays. doi:10.1002/9780470559277.ch1
  10. Zhang B, et al. Perfusion-based microfluidic platforms and reagent purity requirements. doi:10.1039/C9LC00580C

Satisfaction
Quality Rating
Value Rating
Style Rating
X