FluxMPS™ Minimum Essential Medium (MEM), Low Glucose w/o Sodium Bicarbonate: 1X Liquid

Product#: DCP-MEM-BN1X
$34.10
DCP-MEM-BN1X
Availability:
Ships in 1-2 Weeks

warning For Research Use Only (RUO). Not intended for clinical, diagnostic, or therapeutic use in humans.
ISO 13485 Certified Manufacturing

FluxMPS™ Minimum Essential Medium (MEM), Low Glucose w/o Sodium Bicarbonate: 1X Liquid

Contains L-Glutamine Contains Phenol Red Contains Calcium Contains Magnesium Contains Glucose Contains Sodium Pyruvate Without Sodium Bicarbonate Without HEPES

FluxMPS™ Minimum Essential Medium (MEM), Low Glucose w/o Sodium Bicarbonate: 1X Liquid is a Microfluidics Suitable, quadruple-stage ultra-filtered (0.1 µm ×2 + 0.04 µm ×2) cell culture medium engineered for organ-on-a-chip (OoC), tissue-on-a-chip (ToC), and microphysiological system (MPS) applications. A quadruple-stage train (0.1 µm ×2 + 0.04 µm ×2) reaches a 0.04 µm final cut-off, five times finer than the 0.22 µm membranes used for conventional sterile filtration.

  • Quadruple-stage filtration: 0.1 µm (Prefiltration I & II) + 0.04 µm (Final filtration I & II), four validated passes
  • Batch release specification — Endotoxin < 0.05 EU/mL (LAL, USP <85> BET)
  • MEM base formulation, low glucose (1.0 g/L); pH 7.4 (USP <791>); formulated without sodium bicarbonate
  • Contains L-Glutamine (292 mg/L), Sodium Pyruvate (110 mg/L), and Phenol Red (11 mg/L)
  • Prepared with Ultrapure Type 1 water (18.2 MΩ·cm)
  • ISO Class 5 aseptic fill & finish; manufactured under an ISO 13485:2016 quality management system
  • Mycoplasma risk controlled by 0.1 µm mycoplasma-retentive filtration (not tested per lot)
  • Custom formulations available — pH, glucose, salts, HEPES, and nutrient composition on request
DCP-MEM-BN1X | Sizes: 500 mL, 1000 mL | Cell Culture Media UNSPSC: 41116155 | Commodity: Molecular biology and cell culture growth media | (UNv260801)
Minimum Essential Medium (MEM), Low Glucose w/o Sodium Bicarbonate: 1X Liquid
  • Glucose1000 mg/L (1.0 g/L)
  • L-Glutamine292 mg/L
  • Sodium Pyruvate110 mg/L
  • pH (USP <791>)7.4
  • Osmolality (USP <785>)Contact for specification
  • Endotoxin (USP <85>)< 0.05 EU/mL
  • Filtration0.1 µm ×2 + 0.04 µm ×2 (Quadruple-stage)
  • Storage2–8°C, protect from light
  • Shelf Life12 months from date of manufacture, unopened
  • ShippingCold pack
ISO 13485:2016 USP <85> <785> <788> RUO
Why FluxMPS™

Engineered where standard media fails

Conventional 0.22 µm-filtered media carry mycoplasma-sized particulates (0.2–0.3 µm), subvisible debris, and lot-to-lot endotoxin variation that accumulate inside microchannels — corrupting biosensor readings and shortening device lifetimes. FluxMPS™ is built to address these failure modes at the filtration stage.

filter_alt

Microchannel-safe purity

0.04 µm final filter retains particles to sub-mycoplasma size; USP <788> Method 1 (light obscuration) particulate compliance verified per lot.

target

Defined metabolic profile

Fixed low-glucose carbon source and precise amino acid/vitamin concentrations support reproducible metabolic flux experiments.

water_drop

Ultrapure-grade water

Prepared with Type 1 water (18.2 MΩ·cm) under trace-metal and organic-carbon (TOC) control, reducing chemical background contributed by the feed water itself.

visibility

Low background for imaging

Controlled particulate baseline from quadruple-stage filtration supports confocal microscopy, live-cell biosensors, and TEER measurement setups where debris interference is unacceptable.

science

Rich, stable nutrient profile

Micro-batch precision locks in amino acid and vitamin concentrations for lot-to-lot reproducibility in long-term perfusion studies.

tune

Customization on demand

pH, glucose, salts, HEPES, and full nutrient composition available on request. Contact support@diagnocine.com.

Purity Architecture

Quadruple-stage filtration system

FluxMPS™ Minimum Essential Medium (MEM), Low Glucose w/o Sodium Bicarbonate: 1X Liquid is processed through a four-stage filtration train reaching a 0.04 µm final pore size — two dedicated prefilter + final-filter pairs run in series, each 0.04 µm final filter protected by its own 0.1 µm prefilter.

  1. 1

    0.1 µm Prefiltration I

    Removes large particulates and protein aggregates; protects the first 0.04 µm final filter cartridge.

  2. 2

    0.04 µm Final filtration I

    First 0.04 µm pass; retains sub-micron particulates and mycoplasma-sized organisms (0.2–0.3 µm) not captured by standard 0.22 µm filtration.

  3. 3

    0.1 µm Prefiltration II

    Second dedicated prefilter, protecting the second 0.04 µm final filter cartridge.

  4. 4

    0.04 µm Final filtration II — Polish

    Ultimate polishing filter; aseptic fill & finish in a validated ISO Class 5 laminar-flow workstation.

Performance vs. conventional media

Four sequential stages reaching 0.04 µm deliver approximately 5× cleaner media by particulate count compared to single-pass 0.22 µm filtration.

5×
 
0.04
µm final filter pore size — sub-mycoplasma polishing
Sterility assurance: Every lot undergoes 14-day USP <71> sterility testing. Mycoplasma risk is controlled by 0.1 µm mycoplasma-retentive filtration; this is a filtration statement, not a per-lot mycoplasma assay result.
Grade: This product is Microfluidics Suitable, filtered to a 0.04 µm final cut-off. It is not an MPS Grade product — that designation is reserved for the 0.01 µm ultra nano-filtered line, which adds 0.02 µm and 0.01 µm stages after the 0.04 µm polish. For applications requiring the 0.01 µm cut-off, contact support@diagnocine.com.
FluxMPS(TM) Minimum Essential Medium (MEM), Low Glucose w/o Sodium Bicarbonate: 1X Liquid (DCP-MEM-BN1X) Quadruple-stage filtration system: 0.1 micron Prefiltration I, 0.04 micron Final filtration I, 0.1 micron Prefiltration II, 0.04 micron Final filtration II - Polish for organ-on-a-chip and microfluidic applications by Diagnocine
Figure 1. FluxMPS™ Quadruple-stage filtration architecture (0.1 µm ×2 + 0.04 µm ×2).
© Diagnocine® — DCP-MEM-BN1X
Applications

Designed for next-generation cell culture platforms

FluxMPS™ Minimum Essential Medium (MEM), Low Glucose w/o Sodium Bicarbonate: 1X Liquid is validated for organ-on-a-chip, metabolic research, live-cell imaging, and primary cell models where particulate contamination and endotoxin variation are unacceptable.

Automated Bioreactors & Robotics

Next-Generation System Uptime

An optional 0.01 µm (10 nm) ultra nano-filtered MPS Grade variant of this formulation is available for automated bioreactor and robotic perfusion systems requiring the ultimate particulate exclusion — a separate tier from the Microfluidics Suitable product on this page.

  • Total Particulate Exclusion: 10 nm filtration for nanoscale valve and sensor protection
  • Valve & Sensor Protection: prevents particulate-induced blockage in precision fluidic systems
  • Extended Perfusion Stability: maintains flow rate consistency across multi-week automated runs

Inquiry Required: Contact support@diagnocine.com to request the 0.01 µm MPS Grade variant.

Microfluidics

Micro Physiological System (MPS) & Chip

Ultra-filtered formulation prevents microchannel clogging and maintains laminar flow integrity.

OoCToCBoCLoCMPS
Cancer Biology

Warburg Effect & Metabolic Research

Defined low-glucose carbon source and controlled endotoxin release specification support precise metabolic flux analysis.

MCF-7MDA-MB-231HeLaHT-1080
Stem Cell Biology

iPSC-Derived Models

Ultrafiltered formulation supports sensitive iPSC differentiation protocols where endotoxin variation causes off-target effects.

iPSC-NeuronsiPSC-CMiPSC-Hep
Vascular Biology

Endothelial & Primary Cells

Microchannel-safe purity supports endothelial barrier integrity and TEER measurement stability.

HUVECsBHK-21Primary fibroblasts
Metabolomics

Metabolic Flux Analysis

Chemically defined base supports isotope tracing workflows. Not compatible with Agilent Seahorse XF assays, which require bicarbonate-free, phenol red-free medium — this formulation contains phenol red.

13C tracingNMR metabolomics
Live-Cell Imaging

Microscopy & Optical Sensing

Controlled particulate baseline supports confocal imaging and biosensor integration setups requiring minimal debris interference.

ConfocalBiosensorsTEER
Technical Specifications

Lot-release quality parameters

Every production lot of FluxMPS™ Minimum Essential Medium (MEM), Low Glucose w/o Sodium Bicarbonate: 1X Liquid undergoes the complete quality-release battery below before shipment. Available pack sizes: 500 mL, 1000 mL.

Physical & Chemical Parameters
Parameter Specification
Formulation MEM, Low Glucose, with L-Glutamine, Sodium Pyruvate, Phenol Red; without Sodium Bicarbonate, without HEPES
Appearance Orange-to-red colored, clear solution (phenol red present)
pH USP <791> 7.4
Osmolality USP <785> Contact for specification
Glucose 1000 mg/L (1.0 g/L)
L-Glutamine 292 mg/L
Sodium Pyruvate 110 mg/L
Phenol Red 11 mg/L (present)
Sterility, Purity & Safety Parameters
Parameter Specification
Endotoxin USP <85> BET < 0.05 EU/mL
Sterility USP <71> No growth after 14 days
Mycoplasma Controlled by 0.1 µm mycoplasma-retentive filtration (not tested per lot)
Particulate ≥10 µm USP <788> Method 1 Compliant
Particulate ≥25 µm USP <788> Method 1 Compliant
Water Purity ASTM D1193 Type I Ultrapure Type 1, 18.2 MΩ·cm
Manufacturing std. ISO 13485 ISO 13485:2016
Fill environment ISO Class 5 (Class 100)
Storage, Handling & Logistics
Parameter Specification
Storage temperature 2–8°C, protected from light
Freeze-thaw Not recommended
Shelf life 12 months from date of manufacture, unopened
Shipping condition Cold pack
CO₂ requirement Optional (no sodium bicarbonate present); supplement with HEPES or bicarbonate as needed for CO₂-independent culture
Raw Materials & Regulatory Traceability
Parameter Specification
Raw material grade Cell culture / reagent grade
Traceability Full lot documentation, CoA available
Manufacturing QMS ISO 13485:2016 certified
Grade Microfluidics Suitable (0.04 µm final cut-off)
Regulatory alignment 21 CFR Part 820 (QMSR) aligned
Production method Micro-batch precision manufacturing
Intended use For Research Use Only (RUO)
Formulation

Full composition (mg/L)

Complete formulation with CAS numbers, reproduced from manufacturer specification. Total: 29 components across 4 groups (Inorganic Salts, Amino Acids, Vitamins, Others). Custom compositions available on request.

Component CAS Number mg/L
INORGANIC SALTS
Calcium chloride dihydrate 10035-04-8 265.000
Magnesium sulfate anhydrous 7487-88-9 97.720
Potassium chloride 7447-40-7 400.000
Sodium chloride 7647-14-5 6800.00
Sodium phosphate dibasic anhydrous 7558-79-4 122.000
Component CAS Number mg/L
AMINO ACIDS
L-Arginine hydrochloride 1119-34-2 126.000
L-Cystine dihydrochloride 30189-89-0 31.300
L-Glutamine 56-85-9 292.000
L-Histidine hydrochloride monohydrate 5934-29-2 42.000
L-Isoleucine 73-32-5 52.000
L-Leucine 61-90-5 52.000
L-Lysine hydrochloride 657-27-2 72.500
L-Methionine 63-68-3 15.000
L-Phenylalanine 63-91-2 32.000
L-Threonine 72-19-5 48.000
L-Tryptophan 73-22-3 10.000
L-Tyrosine disodium salt 69847-45-6 51.900
L-Valine 72-18-4 46.000
Component CAS Number mg/L
VITAMINS
Choline chloride 67-48-1 1.000
D-Ca-Pantothenate 137-08-6 1.000
Folic acid 59-30-3 1.000
Niacinamide 98-92-0 1.000
Pyridoxine hydrochloride 58-56-0 1.000
Riboflavin 83-88-5 0.100
Thiamine hydrochloride 67-03-8 1.000
OTHERS
i-Inositol 87-89-8 2.000
D-Glucose 50-99-7 1000.000
Phenol red sodium salt 34487-61-1 11.000
Sodium Pyruvate 113-24-6 110.000
Customization: pH, glucose, salt balance, HEPES, and full nutrient profile available on request. Contact support@diagnocine.com.
Quality Assurance

ISO 13485:2016 manufacturing & compliance

Manufactured under ISO 13485:2016 QMS with final packaging, testing, and customization at Diagnocine Precision in Totowa, New Jersey, USA.

verified

ISO 13485:2016 QMS

Full quality management system certification covering manufacturing, testing, and release for every production lot.

water_drop

Ultrapure Type 1 Water

All media prepared with 18.2 MΩ·cm resistivity water (ASTM D1193 Type I) under trace-metal and TOC control.

biotech

ISO Class 5 Fill & Finish

Aseptic filling in validated ISO Class 5 laminar-flow workstations; 21 CFR Part 820 (QMSR) aligned.

assignment

Micro-Batch Precision

Small-batch manufacturing ensures lot-to-lot nutrient consistency for reproducible perfusion studies.

Batch-level quality control. Endotoxin is controlled per manufacturing batch rather than per unit. Every batch is tested before release and must meet the release specification:
  • Endotoxin — LAL assay, USP <85> Bacterial Endotoxins Test; assay sensitivity 0.005 EU/mL; release specification < 0.05 EU/mL
  • pH, osmolality, conductivity, appearance and clarity
  • Sterility
A Certificate of Analysis is available on request.

Endotoxin — USP <85> BET

LAL assay per batch prior to release. Release specification: < 0.05 EU/mL.

Particulate — USP <788> Method 1

Light obscuration particle count confirms ≥10 µm and ≥25 µm compliance per batch.

Osmolality — USP <785>

Freezing-point osmometry per USP <785>. Result: contact for specification.

Documentation — CoA & Full Lot Records

Certificate of Analysis with full QC panel, traceability, and release signatures for every lot.

Certificate of Analysis: Request via support@diagnocine.com with your lot number.
Product Comparison

How DCP-MEM-BN1X (FluxMPS™) compares

Side-by-side comparison against conventional 0.22 µm-filtered alternatives of the same base formulation. Competitor cells with no attributed published specification are shown as "Not specified".

Parameter DCP-MEM-BN1X (FluxMPS™) Conventional MEM (0.22 µm) Standard MEM alternative
Grade Microfluidics Suitable Not specified Not specified
Base formulation MEM, Low Glucose, w/o Sodium Bicarbonate: 1X Liquid Not specified Not specified
Final filtration pore size 0.04 µm Not specified Not specified
Number of filtration stages 4 stages Not specified Not specified
Mycoplasma barrier filtration check_circle 0.1 µm retentive Not specified Not specified
Endotoxin (release specification) FluxMPS™ — < 0.05 EU/mL Corning classical liquid media — < 0.25 EU/mL
Sigma-Aldrich DMEM complete medium — ≤ 2 EU/mL
Gibco classical DMEM — Not specified (recorded per lot)
USP particulate compliance check_circle USP <788> Method 1 Not specified Not specified
Water quality Ultrapure Type 1 (18.2 MΩ) Not specified Not specified
Manufacturing QMS ISO 13485:2016 Not specified Not specified
Microfluidic compatibility check_circle Validated Not specified Not specified
Custom formulation check_circle On request Not specified Not specified

Comparison figures from published supplier specifications, accessed 2026-09-02. Suppliers that publish no numeric endotoxin specification are shown as "Not specified".

FAQ

Frequently asked questions

Common questions about FluxMPS™ Minimum Essential Medium (MEM), Low Glucose w/o Sodium Bicarbonate: 1X Liquid and Microfluidics Suitable cell culture media.

Yes. DCP-MEM-BN1X uses our Quadruple-stage filtration (0.1 µm ×2 + 0.04 µm ×2), delivering ultra-low particulate counts that prevent microchannel clogging in OoC and MPS devices.
Standard 0.22 µm filtration leaves intact mycoplasma (0.2–0.3 µm) and subvisible particulates that accumulate in microchannels. FluxMPS™ uses four sequential passes (0.1 µm ×2 + 0.04 µm ×2) reaching a 0.04 µm final cut-off, delivering approximately 5× lower particulate counts and USP <788> Method 1 (light obscuration) particulate compliance.
This formulation omits sodium bicarbonate so users can select their own buffering strategy. It also does not currently contain HEPES. For standard CO₂ incubator culture, supplementing with sodium bicarbonate restores conventional buffering; for CO₂-independent or open-dish work, add HEPES. Contact support@diagnocine.com for a custom pre-buffered formulation.
This formulation contains no sodium bicarbonate, so CO₂ requirement is optional and depends on your buffering strategy. If used in an open or CO₂-independent system, supplement with HEPES or an alternate buffer to maintain pH stability.
Yes. FluxMPS™ Minimum Essential Medium (MEM), Low Glucose w/o Sodium Bicarbonate: 1X Liquid can be supplemented with FBS, growth factors, antibiotics, or other additives per standard practice. Pre-filter serum-containing supplements through a 0.2 µm low-protein-binding PES or PVDF filter before adding — never a 0.04 µm filter, which strips serum proteins and lipoproteins. Add supplements immediately before use.
Endotoxin is controlled per manufacturing batch. Every batch is tested by LAL assay per USP <85> BET and must meet the release specification of < 0.05 EU/mL before shipment. A Certificate of Analysis with the batch result is available from support@diagnocine.com.
Yes. A lot-specific CoA is available for every shipment and includes: appearance, pH (USP <791>), osmolality (USP <785>), endotoxin (USP <85> BET), sterility (USP <71>), particulate matter (USP <788> Method 1), raw material traceability, manufacturing date, and authorized release signatures. Request via support@diagnocine.com.
Scientific References

Supporting literature

Peer-reviewed publications supporting ultra-filtered, microfluidics-suitable media and microfluidic cell culture applications.

  1. Huh D et al. (2010). Reconstituting organ-level lung functions on a chip. Science, 328(5986), 1662–1668. doi:10.1126/science.1188302
  2. Bhatia SN & Ingber DE (2014). Microfluidic organs-on-chips. Nature Biotechnology, 32(8), 760–772. doi:10.1038/nbt.2989
  3. Eagle H (1959). Amino acid metabolism in mammalian cell cultures. Science, 130(3373), 432–437. doi:10.1126/science.130.3373.432
  4. Bhattacharya S et al. (2018). Challenges in maintaining cell viability during microfluidic experiments. Electrophoresis, 39(7), 997–1006. doi:10.1002/elps.201700375
  5. Zhang YS et al. (2017). Multisensor-integrated organs-on-chips platform for automated in situ monitoring. PNAS, 114(12), E2293–E2302. doi:10.1073/pnas.1612906114
  6. Vernetti L et al. (2017). Functional coupling of human microphysiology systems. Scientific Reports, 7, 42296. doi:10.1038/srep42296
  7. Esch EW et al. (2015). Organs-on-chips at the frontiers of drug discovery. Nature Reviews Drug Discovery, 14(4), 248–260. doi:10.1038/nrd4539
  8. Zheng F et al. (2021). Organ-on-a-chip systems: microengineering to biomimic living systems. Small, 17(7), 2004175. doi:10.1002/smll.202004175

Satisfaction
Quality Rating
Value Rating
Style Rating
X