FluxMPS™ Minimum Essential Medium (MEM), High Glucose w/o Sodium Pyruvate, Phenol Red: 1X Liquid

Product#: DCP-MEMG-PRN1X
$34.10
DCP-MEMG-PRN1X
Availability:
Ships in 1-2 Weeks

warning For Research Use Only (RUO). Not intended for clinical, diagnostic, or therapeutic use in humans.
ISO 13485 Certified Manufacturing

FluxMPS™ Minimum Essential Medium (MEM), High Glucose w/o Sodium Pyruvate, Phenol Red: 1X Liquid

Contains L-Glutamine Contains Sodium Bicarbonate Contains Calcium Contains Magnesium Contains Glucose Without Phenol Red Without HEPES Without Sodium Pyruvate

FluxMPS™ Minimum Essential Medium (MEM), High Glucose w/o Sodium Pyruvate, Phenol Red: 1X Liquid is a Microfluidics Suitable, quadruple-stage ultra-filtered (0.1 µm ×2 + 0.04 µm ×2) 1X liquid cell culture medium engineered for organ-on-a-chip (OoC), tissue-on-a-chip (ToC), and microphysiological system (MPS) applications. The high-glucose (4.5 g/L), phenol-red-free, sodium-pyruvate-free classical MEM formulation is processed through a validated four-pass filtration train reaching a 0.04 µm final pore size — well beyond the 0.22 µm industry standard — for microchannel-safe purity.

  • High glucose (4.5 g/L) classical Eagle's MEM (Earle's salts) formulation prepared without sodium pyruvate and without phenol red — suited to high-energy-demand cell types and optical assays sensitive to phenol red interference
  • Quadruple-stage filtration train: 0.1 µm (Prefiltration I & II) + 0.04 µm (Final filtration I & II — Polish), four sequential passes
  • Endotoxin release specification: < 0.05 EU/mL (LAL assay, USP <85> Bacterial Endotoxins Test), controlled per manufacturing batch
  • pH 7.4 (USP <791>); sodium bicarbonate buffered (2200 mg/L), consistent with an approximately 5.8% CO₂ incubator atmosphere
  • Prepared with Ultrapure Type 1 water (18.2 MΩ·cm); aseptic fill performed in an ISO Class 5 environment
  • Manufactured under an ISO 13485:2016 quality management system; final QC and customization at Diagnocine, Totowa, NJ
  • Custom formulations available — pH, glucose, salts, HEPES, and nutrient composition on request via support@diagnocine.com
DCP-MEMG-PRN1X | Cell Culture Media
UNSPSC: 41116155 | Commodity: Molecular biology and cell culture growth media | (UNv260801)
Minimum Essential Medium (MEM), High Glucose w/o Sodium Pyruvate, Phenol Red: 1X Liquid
  • Glucose4500 mg/L (4.5 g/L)
  • L-Glutamine292 mg/L
  • Sodium PyruvateNot added
  • pH (USP <791>)7.4
  • Osmolality (USP <785>)See Certificate of Analysis
  • Endotoxin (USP <85>)< 0.05 EU/mL
  • Filtration0.1 µm ×2 + 0.04 µm ×2
  • Storage2–8°C, protect from light
  • Shelf Life12 months from date of manufacture, unopened
  • ShippingCold pack
ISO 13485:2016 USP <85> <785> <788> RUO
Why FluxMPS™

Engineered where standard media fails

Conventional 0.22 µm-filtered media carry mycoplasma-sized particulates (0.2–0.3 µm), subvisible debris, and lot-to-lot endotoxin variability that accumulate inside microchannels — corrupting biosensor readings and shortening device lifetimes. FluxMPS™ addresses these failure modes with a validated four-pass filtration train.

filter_alt

Microchannel-safe purity

Four-stage filtration reaching a 0.04 µm final pore size retains particulates to sub-mycoplasma dimensions; USP <788> Method 1 (light obscuration) particulate testing is performed on every production lot.

target

High-glucose metabolic support

4.5 g/L glucose supports high-energy-demand cell types including HeLa, MCF-7, fibroblasts, and iPSC-derived models in perfusion devices.

water_drop

Ultrapure-grade water

Prepared with Type 1 water (18.2 MΩ·cm) for trace-metal and organic-carbon control, minimizing extraneous chemical background in the finished medium.

visibility

Low background for imaging

Ultra-low particulate baseline (0.04 µm final filtration) supports confocal microscopy, live-cell biosensors, and TEER measurements. Note that riboflavin in this formulation is intrinsically autofluorescent (excitation ∼444 nm / emission ∼525 nm) and should be accounted for in fluorescence channel selection.

science

Rich, stable nutrient profile

A complete complement of 13 essential amino acids per classical Eagle's MEM chemistry, plus micro-batch precision manufacturing, ensures consistent nutrient delivery for demanding cell culture models.

tune

Customization on demand

pH, glucose, salts, HEPES, and full nutrient composition available on request. Contact support@diagnocine.com.

Purity Architecture

Quadruple-stage filtration system

FluxMPS™ Minimum Essential Medium (MEM), High Glucose w/o Sodium Pyruvate, Phenol Red: 1X Liquid is processed through a four-pass filtration sequence — two dedicated prefilter/final-filter pairs — reaching a 0.04 µm final pore size, addressing mycoplasma-sized organisms and subvisible particulates that a single 0.22 µm pass does not remove.

  1. 1

    0.1 µm Prefiltration I

    Removes large particulates, cell debris, and protein aggregates; protects the first 0.04 µm final filter cartridge.

  2. 2

    0.04 µm Final filtration I

    First 0.04 µm pass; retains sub-micron particulates and microaggregates that a 0.22 µm filter cannot capture, including mycoplasma-sized organisms (0.2–0.3 µm).

  3. 3

    0.1 µm Prefiltration II

    Second dedicated prefilter stage, protecting the second 0.04 µm final filter cartridge from particulate loading.

  4. 4

    0.04 µm Final filtration II — Polish

    Ultimate polishing filtration immediately prior to aseptic fill and finish.

Filtration architecture

Two prefilter/final-filter pairs run in series to a 0.04 µm final pore size, with USP <788> Method 1 particulate compliance verified on every production lot.

4
Sequential filtration passes (0.1 µm ×2 + 0.04 µm ×2)
0.04
µm final filter pore size — sub-mycoplasma polishing
Sterility assurance: Every lot undergoes 14-day USP <71> sterility testing. Mycoplasma is controlled by 0.1 µm mycoplasma-retentive filtration (not tested per lot); no bacterial or fungal growth is observed in the 14-day sterility test.
Grade: This product is Microfluidics Suitable, filtered to a 0.04 µm final cut-off. It is not an MPS Grade product — that designation is reserved for the 0.01 µm ultra nano-filtered line, which adds 0.02 µm and 0.01 µm stages after the 0.04 µm polish. For applications requiring the 0.01 µm cut-off, contact support@diagnocine.com.
FluxMPS™ Minimum Essential Medium (MEM), High Glucose w/o Sodium Pyruvate, Phenol Red: 1X Liquid (DCP-MEMG-PRN1X) quadruple-stage filtration system: 0.1 μm Prefiltration I, 0.04 μm Final filtration I, 0.1 μm Prefiltration II, 0.04 μm Final filtration II ? Polish, for organ-on-a-chip and microfluidic applications by Diagnocine
Figure 1. FluxMPS™ quadruple-stage filtration architecture (0.1 µm ×2 + 0.04 µm ×2): Prefiltration I, Final filtration I, Prefiltration II, Final filtration II — Polish.
© Diagnocine® — DCP-MEMG-PRN1X
Applications

Designed for next-generation cell culture platforms

FluxMPS™ Minimum Essential Medium (MEM), High Glucose w/o Sodium Pyruvate, Phenol Red: 1X Liquid is suited to organ-on-a-chip, cancer biology, metabolic research, live-cell imaging, and primary cell models where particulate contamination and endotoxin variation are unacceptable.

Automated Bioreactors & Robotics

Next-Generation System Uptime

An optional 0.01 µm (10 nm) MPS Grade ultra nano-filtered variant of this formulation is available for automated bioreactor and robotic perfusion systems requiring the ultimate particulate exclusion.

  • Total Particulate Exclusion: 10 nm MPS Grade filtration for nanoscale valve and sensor protection
  • Valve & Sensor Protection: reduces particulate-induced blockage risk in precision fluidic systems
  • Extended Perfusion Stability: supports flow rate consistency across multi-week automated runs

Inquiry Required: Contact support@diagnocine.com to request the 0.01 µm MPS Grade variant.

Microfluidics

Micro Physiological System (MPS) & Chip

Ultra-filtered formulation helps prevent microchannel clogging and supports laminar flow integrity across complex chip geometries.

OoCToCBoCLoCMPS
Cancer Biology

Warburg Effect & Metabolic Research

High-glucose base supports Warburg effect studies and glucose uptake assays in cancer cell lines.

MCF-7MDA-MB-231HeLaHT-1080
Stem Cell Biology

iPSC-Derived Models

Ultrapure formulation supports sensitive iPSC differentiation protocols where endotoxin variability causes off-target effects.

iPSC-NeuronsiPSC-CMiPSC-Hep
Vascular Biology

Endothelial & Primary Cells

Microchannel-safe purity supports endothelial barrier integrity and TEER measurement in perfusion models.

HUVECsBHK-21Primary fibroblasts
Metabolomics

Metabolic Flux Analysis

High-glucose base enables precise ¹³C isotope tracing and glycolytic flux experiments. Not compatible with Agilent Seahorse XF assays, which require bicarbonate-free, phenol red-free medium; this formulation contains sodium bicarbonate.

13C tracingNMR metabolomics
Live-Cell Imaging

Microscopy & Optical Sensing

Ultra-low particulate load supports high-content confocal imaging and optical biosensor integration; account for intrinsic riboflavin autofluorescence when selecting fluorescence channels.

ConfocalBiosensorsTEER
Technical Specifications

Lot-release quality parameters

Every production batch of FluxMPS™ Minimum Essential Medium (MEM), High Glucose w/o Sodium Pyruvate, Phenol Red: 1X Liquid undergoes the quality-release battery below before shipment.

Physical & Chemical Parameters
Parameter Specification
Formulation High Glucose (4.5 g/L) + L-Glutamine + Sodium Bicarbonate + Calcium + Magnesium; without Sodium Pyruvate, without Phenol Red, without HEPES
Appearance Colorless to pale yellow, clear solution (phenol red-free)
pH USP <791> 7.4
Osmolality USP <785> See Certificate of Analysis (lot-specific)
Glucose 4500 mg/L (4.5 g/L)
L-Glutamine 292 mg/L
Sodium Pyruvate Not added
Phenol Red Not added
Sterility, Purity & Safety Parameters
Parameter Specification
Endotoxin USP <85> BET < 0.05 EU/mL (release specification; see §Manufacturing for batch-testing detail)
Sterility USP <71> No growth after 14 days
Mycoplasma Controlled by 0.1 µm mycoplasma-retentive filtration (not tested per lot)
Particulate ≥10 µm USP <788> Method 1 Compliant
Particulate ≥25 µm USP <788> Method 1 Compliant
Water Purity Ultrapure Type 1, 18.2 MΩ·cm
Manufacturing std. ISO 13485 ISO 13485:2016
Fill environment ISO Class 5 (Class 100)
Storage, Handling & Logistics
Parameter Specification
Storage temperature 2–8°C, protect from light
Freeze-thaw Not recommended
Shelf life 12 months from date of manufacture, unopened
Shipping condition Cold pack
CO₂ requirement Approximately 5.8% CO₂ (derived from 2200 mg/L sodium bicarbonate at pH 7.4 via Henderson-Hasselbalch)
Raw Materials & Regulatory Traceability
Parameter Specification
Raw material grade Cell culture / reagent grade
Traceability Full lot documentation, CoA available
Manufacturing QMS ISO 13485:2016 certified
UNSPSC 41116155 — Molecular biology and cell culture growth media (UNv260801)
Regulatory alignment 21 CFR Part 820 (QMSR) aligned
Production method Micro-batch precision manufacturing
Available sizes 500 mL, 1000 mL
Intended use For Research Use Only (RUO)
Formulation

Full composition (mg/L)

Total: 28 components across 4 categories (INORGANIC SALTS, AMINO ACIDS, VITAMINS, OTHERS), reproduced in full from the manufacturer specification with CAS numbers. Custom compositions available on request.

Component CAS Number mg/L
INORGANIC SALTS
Calcium chloride dihydrate 10035-04-8 265.000
Magnesium sulfate anhydrous 7487-88-9 97.720
Potassium chloride 7447-40-7 400.000
Sodium bicarbonate 144-55-8 2200.000
Sodium chloride 7647-14-5 6800.00
Sodium phosphate dibasic anhydrous 7558-79-4 122.000
Component CAS Number mg/L
AMINO ACIDS
L-Arginine hydrochloride 1119-34-2 126.000
L-Cystine dihydrochloride 30189-89-0 31.300
L-Glutamine 56-85-9 292.000
L-Histidine hydrochloride monohydrate 5934-29-2 42.000
L-Isoleucine 73-32-5 52.000
L-Leucine 61-90-5 52.000
L-Lysine hydrochloride 657-27-2 72.500
L-Methionine 63-68-3 15.000
L-Phenylalanine 63-91-2 32.000
L-Threonine 72-19-5 48.000
L-Tryptophan 73-22-3 10.000
L-Tyrosine disodium salt 69847-45-6 51.900
L-Valine 72-18-4 46.000
Component CAS Number mg/L
VITAMINS
Choline chloride 67-48-1 1.000
D-Ca-Pantothenate 137-08-6 1.000
Folic acid 59-30-3 1.000
Niacinamide 98-92-0 1.000
Pyridoxine hydrochloride 58-56-0 1.000
Riboflavin 83-88-5 0.100
Thiamine hydrochloride 67-03-8 1.000
i-Inositol 87-89-8 2.000
OTHERS
D-Glucose 50-99-7 4500.000
Customization: pH, glucose, salt balance, HEPES, sodium pyruvate, phenol red, and full nutrient profile available on request. Contact support@diagnocine.com.
Quality Assurance

ISO 13485:2016 manufacturing & compliance

Manufactured under an ISO 13485:2016 quality management system with final packaging, testing, and customization at Diagnocine Precision in Totowa, New Jersey, USA.

verified

ISO 13485:2016 QMS

Full quality management system certification covering manufacturing, testing, and release for every production lot.

water_drop

Ultrapure Type 1 Water

Media prepared with 18.2 MΩ·cm resistivity water for trace-metal and organic-carbon control.

biotech

ISO Class 5 Fill & Finish

Aseptic filling in a validated ISO Class 5 laminar-flow workstation; 21 CFR Part 820 (QMSR) aligned.

assignment

Micro-Batch Precision

Small-batch manufacturing supports lot-to-lot nutrient consistency for reproducible perfusion studies.

Batch-level quality control. Endotoxin is controlled per manufacturing batch rather than per unit. Every batch is tested before release and must meet the release specification:
  • Endotoxin — LAL assay, USP <85> Bacterial Endotoxins Test; assay sensitivity 0.005 EU/mL; release specification < 0.05 EU/mL
  • pH, osmolality, conductivity, appearance and clarity
  • Sterility
A Certificate of Analysis is available on request.

Endotoxin — USP <85> BET

LAL assay per manufacturing batch. Release specification: < 0.05 EU/mL.

Particulate — USP <788> Method 1

Light obscuration particle count confirms ≥10 µm and ≥25 µm compliance per lot.

Osmolality — USP <785>

Freezing-point osmometry per USP <785>. Result: see Certificate of Analysis.

Documentation — CoA & Full Lot Records

Certificate of Analysis with full QC panel, traceability, and release signatures for every lot.

Certificate of Analysis: Request via support@diagnocine.com with your lot number.
Product Comparison

How DCP-MEMG-PRN1X (FluxMPS™) compares

Side-by-side comparison against conventional 0.22 µm-filtered MEM High Glucose alternatives.

Parameter DCP-MEMG-PRN1X (FluxMPS™) Conventional MEM High Glucose (0.22 µm) Standard MEM High Glucose alternative
Grade Microfluidics Suitable (0.04 µm final filtration) Standard grade (0.22 µm filtration) Standard grade (0.22 µm filtration)
Formulation trait High glucose (4.5 g/L), sodium pyruvate-free, phenol red-free Standard glucose, phenol red included Variable formulation
Final filtration pore size 0.04 µm 0.22 µm 0.22 µm
Number of filtration stages 4 passes 1 pass 1–2 passes
Mycoplasma barrier filtration check_circle cancel cancel
Endotoxin (release specification) FluxMPS™ — < 0.05 EU/mL Corning classical liquid media — < 0.25 EU/mL
Sigma-Aldrich DMEM complete medium — ≤ 2 EU/mL
Gibco classical DMEM — Not specified (recorded per lot)
USP particulate compliance check_circle USP <788> Method 1 cancel cancel
Water quality Ultrapure Type 1 (18.2 MΩ·cm) Purified water Purified water
Manufacturing QMS ISO 13485:2016 Variable Variable
Microfluidic channel compatibility check_circle Validated cancel Risk of clogging cancel Risk of clogging
Custom formulation check_circle On request cancel Limited

Comparison figures from published supplier specifications, accessed 2026-09-02. Suppliers that publish no numeric endotoxin specification are shown as "Not specified".

FAQ

Frequently asked questions

Common questions about FluxMPS™ Minimum Essential Medium (MEM), High Glucose w/o Sodium Pyruvate, Phenol Red: 1X Liquid and Microfluidics Suitable cell culture media.

Yes. DCP-MEMG-PRN1X is Microfluidics Suitable, processed through our quadruple-stage filtration train (0.1 µm ×2 + 0.04 µm ×2), delivering ultra-low particulate counts that reduce the risk of microchannel clogging in OoC and MPS devices.
Standard 0.22 µm filtration leaves intact mycoplasma-sized particulates (0.2–0.3 µm) and other subvisible debris that can accumulate in microchannels over time. FluxMPS™ uses four sequential filtration passes (0.1 µm ×2 + 0.04 µm ×2) reaching a 0.04 µm final pore size, with USP <788> Method 1 particulate testing performed on every production lot.
This formulation is prepared at 4.5 g/L (high) glucose without sodium pyruvate and without phenol red, matching classical Eagle's MEM (Earle's salts) chemistry for cell types with high energy demand or for optical assays where phenol red absorbance would interfere with readouts. If your protocol requires added sodium pyruvate, phenol red, or a different glucose concentration, contact support@diagnocine.com for a custom formulation.
Yes. This formulation contains sodium bicarbonate (2,200 mg/L) and is designed for pH 7.4 under an approximately 5.8% CO₂ atmosphere (calculated via the Henderson-Hasselbalch equation); set your incubator CO₂ accordingly and verify pH under your own culture conditions.
Yes. This medium can be supplemented with FBS (5–20%), growth factors, antibiotics, or other additives per standard practice. Add supplements immediately before use. When adding serum or other protein-containing supplements, filter through a 0.2 µm low-protein-binding PES or PVDF membrane; do not use a 0.04 µm membrane for supplement filtration, as it will retain protein and lipoprotein fractions and clog rapidly.
Every manufacturing batch is tested by LAL assay per USP <85> Bacterial Endotoxins Test (assay sensitivity 0.005 EU/mL) and must meet the release specification of < 0.05 EU/mL before release. Batch-specific results are documented on the Certificate of Analysis, available from support@diagnocine.com.
Yes. A lot-specific CoA is available for every shipment and includes: appearance, pH (USP <791>), osmolality (USP <785>), endotoxin (USP <85> BET), sterility (USP <71>), particulate matter (USP <788> Method 1), raw material traceability, manufacturing date, lot number, expiry, and authorized release signatures. Request via support@diagnocine.com.
Scientific References

Supporting literature

Peer-reviewed publications supporting ultra-filtered media and microfluidic cell culture applications.

  1. Huh D et al. (2010). Reconstituting organ-level lung functions on a chip. Science, 328(5986), 1662–1668. doi:10.1126/science.1188302
  2. Bhatia SN & Ingber DE (2014). Microfluidic organs-on-chips. Nature Biotechnology, 32(8), 760–772. doi:10.1038/nbt.2989
  3. Eagle H (1959). Amino acid metabolism in mammalian cell cultures. Science, 130(3373), 432–437. doi:10.1126/science.130.3373.432
  4. Warburg O (1956). On the origin of cancer cells. Science, 123(3191), 309–314. doi:10.1126/science.123.3191.309
  5. Bhattacharya S et al. (2018). Challenges in maintaining cell viability during microfluidic experiments. Electrophoresis, 39(7), 997–1006. doi:10.1002/elps.201700375
  6. Zhang YS et al. (2017). Multisensor-integrated organs-on-chips for automated in situ monitoring. PNAS, 114(12), E2293–E2302. doi:10.1073/pnas.1612906114
  7. Vernetti L et al. (2017). Functional coupling of human microphysiology systems. Scientific Reports, 7, 42296. doi:10.1038/srep42296
  8. Esch EW et al. (2015). Organs-on-chips at the frontiers of drug discovery. Nature Reviews Drug Discovery, 14(4), 248–260. doi:10.1038/nrd4539
  9. Zheng F et al. (2021). Organ-on-a-chip systems: microengineering to biomimic living systems. Small, 17(7), 2004175. doi:10.1002/smll.202004175

Satisfaction
Quality Rating
Value Rating
Style Rating
X