FluxMPS™ Minimum Essential Medium (MEM), High Glucose & 25mM HEPES: 1X Liquid

Product#: DCP-MEMGH-N1X
$44.00
DCP-MEMGH-N1X
Availability:
Ships in 1-2 Weeks

warning For Research Use Only (RUO). Not intended for clinical, diagnostic, or therapeutic use in humans.
ISO 13485 Certified Manufacturing

FluxMPS™ Minimum Essential Medium (MEM), High Glucose & 25mM HEPES: 1X Liquid

Contains L-Glutamine Contains Sodium Bicarbonate Contains Phenol Red Contains HEPES Contains Calcium Contains Magnesium Contains Glucose Contains Sodium Pyruvate

FluxMPS™ Minimum Essential Medium (MEM), High Glucose & 25mM HEPES: 1X Liquid is a Microfluidics Suitable, ultra-filtered cell culture medium engineered for organ-on-a-chip (OoC), tissue-on-a-chip (ToC), and microphysiological system (MPS) applications. A quadruple-stage train (0.1 µm ×2 + 0.04 µm ×2) reaches a 0.04 µm final cut-off, five times finer than the 0.22 µm membranes used for conventional sterile filtration.

  • High glucose (4.5 g/L) formulation with Non-Essential Amino Acids (NEAA) — supports high-energy-demand cell types
  • Quadruple-stage filtration: 0.1 µm → 0.04 µm → 0.1 µm → 0.04 µm, reaching a 0.04 µm final cut-off
  • Endotoxin release specification: < 0.05 EU/mL (LAL assay, USP <85> BET), tested per manufacturing batch
  • pH 7.4 (USP <791>); 25 mM HEPES buffering alongside 2200 mg/L sodium bicarbonate for flexible CO2 conditions
  • Prepared with Ultrapure Type 1 water (18.2 MΩ·cm)
  • ISO Class 5 aseptic fill & finish; manufactured under an ISO 13485:2016 quality management system, final QC at Diagnocine, Totowa NJ
  • Custom formulations available — pH, glucose, salts, HEPES, and nutrient composition on request
DCP-MEMGH-N1X | Cell Culture Media UNSPSC: 41116155 | Commodity: Molecular biology and cell culture growth media | (UNv260801)
Minimum Essential Medium (MEM), High Glucose & 25mM HEPES: 1X Liquid
  • Glucose4500 mg/L (4.5 g/L)
  • L-Glutamine292 mg/L
  • Sodium Pyruvate110 mg/L
  • HEPES5958 mg/L (25 mM)
  • NEAAIncluded
  • pH (USP <791>)7.4
  • Osmolality (USP <785>)See CoA
  • Endotoxin (USP <85>)< 0.05 EU/mL
  • Filtration0.1 µm ×2 + 0.04 µm ×2
  • Shelf Life12 months from date of manufacture, unopened
ISO 13485:2016 USP <85> <785> <788> RUO
Why FluxMPS™

Engineered where standard media fails

Conventional 0.22 µm-filtered media carry mycoplasma-sized particulates (0.2–0.3 µm), subvisible debris, and batch-to-batch endotoxin variability that accumulate inside microchannels — corrupting biosensor readings and shortening device lifetimes. FluxMPS™ addresses these failure modes at the filtration stage.

filter_alt

Microchannel-safe purity

0.04 µm final filter retains particles to sub-mycoplasma size; USP <788> Method 1 particulate compliance verified per batch.

target

High-glucose metabolic support

4.5 g/L glucose supports high-energy-demand cell types including HeLa, MCF-7, fibroblasts, and iPSC-derived models in perfusion devices.

water_drop

Ultrapure-grade water

Prepared with Type 1 water (18.2 MΩ·cm), supporting strict trace-metal and organic-carbon (TOC) control for sensitive culture applications.

visibility

Low background for imaging

Quadruple-stage filtration maintains a low particulate baseline supporting confocal microscopy, live-cell biosensors, and TEER measurements.

science

Rich, stable nutrient profile

NEAA-supplemented formulation plus micro-batch precision supports comprehensive amino acid coverage for demanding cell culture models.

tune

Customization on demand

pH, glucose, salts, HEPES, and full nutrient composition available on request. Contact support@diagnocine.com.

Purity Architecture

Quadruple-stage filtration system

FluxMPS™ Minimum Essential Medium (MEM), High Glucose & 25mM HEPES: 1X Liquid is processed through a four-stage serial filtration sequence — 0.1 µm → 0.04 µm → 0.1 µm → 0.04 µm — reaching a 0.04 µm final cut-off, providing mycoplasma-retentive filtration and subvisible particulate control beyond what 0.22 µm filtration can address.

  1. 1

    0.1 µm Prefiltration I

    Removes large particulates and aggregates; protects the first 0.04 µm final filter and extends its service life across microchannel-scale flow paths.

  2. 2

    0.04 µm Final filtration I

    Fine particulate and organism removal; provides sub-mycoplasma-size (0.2–0.3 µm) particulate retention beyond standard 0.22 µm filtration.

  3. 3

    0.1 µm Prefiltration II

    Second dedicated prefilter, protecting the second 0.04 µm final filter and providing full redundancy across the train.

  4. 4

    0.04 µm Final filtration II — Polish

    Ultimate polishing filter; aseptic fill performed in a validated ISO Class 5 laminar-flow workstation.

Performance vs. conventional media

Four sequential stages reaching 0.04 µm deliver approximately 5× cleaner media by particulate count compared to single-pass 0.22 µm filtration, with USP <788> Method 1 compliance verified on every production batch.

5×
 
0.04
µm final filter pore size — sub-mycoplasma polishing
Sterility assurance: Every batch undergoes 14-day USP <71> sterility testing; no bacterial or fungal growth observed. Mycoplasma risk is controlled via 0.1 µm mycoplasma-retentive filtration (not tested per lot to USP <63>).
Grade: This product is Microfluidics Suitable, filtered to a 0.04 µm final cut-off. It is not an MPS Grade product — that designation is reserved for the 0.01 µm ultra nano-filtered line, which adds 0.02 µm and 0.01 µm stages after the 0.04 µm polish. For applications requiring the 0.01 µm cut-off, contact support@diagnocine.com.
FluxMPS™ Minimum Essential Medium (MEM), High Glucose & 25mM HEPES: 1X Liquid (DCP-MEMGH-N1X) Quadruple-stage filtration system: 0.1 μm Prefiltration I, 0.04 μm Final Filtration I, 0.1 μm Prefiltration II, 0.04 μm Final Filtration II ? Polish, for organ-on-a-chip and microfluidic applications by Diagnocine
Figure 1. FluxMPS™ Quadruple-stage filtration architecture (0.1 µm ×2 + 0.04 µm ×2) delivering sub-mycoplasma purity for MPS and OoC applications.
© Diagnocine® — DCP-MEMGH-N1X
Applications

Designed for next-generation cell culture platforms

FluxMPS™ Minimum Essential Medium (MEM), High Glucose & 25mM HEPES: 1X Liquid is validated for organ-on-a-chip, cancer biology, metabolic research, live-cell imaging, and primary cell models where particulate contamination and endotoxin variation are unacceptable.

Automated Bioreactors & Robotics

Next-Generation System Uptime

An optional 0.01 µm (10 nm) MPS Grade variant — the six-stage ultra nano-filtered line — is available for automated bioreactor and robotic perfusion systems requiring the ultimate particulate exclusion.

  • Total Particulate Exclusion: 10 nm filtration for nanoscale valve and sensor protection
  • Valve & Sensor Protection: reduces particulate-related blockage risk in precision fluidic systems
  • Extended Perfusion Stability: supports flow rate consistency across multi-week automated runs

Inquiry Required: Contact support@diagnocine.com to request the 0.01 µm MPS Grade variant.

Microfluidics

Micro Physiological System (MPS) & Chip

Ultra-filtered formulation supports laminar flow integrity and reduces microchannel clogging risk across complex chip geometries.

OoCToCBoCLoCMPS
Cancer Biology

Warburg Effect & Metabolic Research

High-glucose base supports Warburg effect studies and glucose uptake assays in cancer cell lines.

MCF-7MDA-MB-231HeLaHT-1080
Stem Cell Biology

iPSC-Derived Models

Ultrapure formulation supports sensitive iPSC differentiation protocols where endotoxin variability causes off-target effects.

iPSC-NeuronsiPSC-CMiPSC-Hep
Vascular Biology

Endothelial & Primary Cells

Microchannel-safe purity supports endothelial barrier integrity and TEER measurements in perfusion models.

HUVECsBHK-21Primary fibroblasts
Metabolomics

Metabolic Flux Analysis

High-glucose base enables precise ¹³C isotope tracing and glycolytic flux experiments. Not compatible with Agilent Seahorse XF assays, which require bicarbonate-free, phenol red-free medium.

13C tracingNMR metabolomics
Live-Cell Imaging

Microscopy & Optical Sensing

Ultra-low particulate load supports high-content confocal imaging and optical biosensor integration.

ConfocalBiosensorsTEER
Technical Specifications

Batch-release quality parameters

Every production batch of FluxMPS™ Minimum Essential Medium (MEM), High Glucose & 25mM HEPES: 1X Liquid undergoes the complete quality-release battery below before shipment.

Physical & Chemical Parameters
Parameter Specification
Formulation Contains: L-Glutamine, Sodium Bicarbonate, Phenol Red, HEPES, Calcium, Magnesium, Glucose, Sodium Pyruvate
Appearance Orange-to-red colored, clear solution
pH USP <791> 7.4
Osmolality USP <785> See CoA
Glucose 4500 mg/L (4.5 g/L)
L-Glutamine 292 mg/L
Sodium Pyruvate 110 mg/L
Phenol Red 11 mg/L (present)
Sterility, Purity & Safety Parameters
Parameter Specification
Endotoxin USP <85> BET < 0.05 EU/mL (batch release specification)
Sterility USP <71> No growth after 14 days
Mycoplasma 0.1 µm mycoplasma-retentive filtration (not tested per lot)
Particulate ≥10 µm USP <788> Method 1 Compliant
Particulate ≥25 µm USP <788> Method 1 Compliant
Water Purity Ultrapure Type 1, 18.2 MΩ·cm
Manufacturing std. ISO 13485 ISO 13485:2016
Fill environment ISO Class 5 (Class 100)
Storage, Handling & Logistics
Parameter Specification
Storage temperature 2–8°C, protected from light
Freeze-thaw Not recommended
Shelf life 12 months from date of manufacture, unopened
Shipping condition Cold pack
CO2 requirement HEPES-buffered; reduced CO2 dependence (standard 5% CO2 incubation compatible)
Raw Materials & Regulatory Traceability
Parameter Specification
Raw material grade Cell culture / reagent grade
Traceability Full lot documentation, CoA available
Manufacturing QMS ISO 13485:2016 certified
UNSPSC 41116155 — Molecular biology and cell culture growth media (UNv260801)
Regulatory alignment 21 CFR Part 820 (QMSR) aligned
Production method Micro-batch precision manufacturing
Intended use For Research Use Only (RUO)
Available pack sizes 500 mL, 1000 mL
Formulation

Full composition (mg/L)

Complete formulation with CAS numbers, reproduced from manufacturer specification. Custom compositions available on request.

Component CAS Number mg/L
INORGANIC SALTS
Calcium chloride dihydrate 10035-04-8 265.000
Magnesium sulfate anhydrous 7487-88-9 97.720
Potassium chloride 7447-40-7 400.000
Sodium bicarbonate 144-55-8 2200.000
Sodium chloride 7647-14-5 6800.00
Sodium phosphate dibasic anhydrous 7558-79-4 122.000
Component CAS Number mg/L
AMINO ACIDS
L-Arginine hydrochloride 1119-34-2 126.000
L-Cystine dihydrochloride 30189-89-0 31.300
L-Glutamine 56-85-9 292.000
L-Histidine hydrochloride monohydrate 5934-29-2 42.000
L-Isoleucine 73-32-5 52.000
L-Leucine 61-90-5 52.000
L-Lysine hydrochloride 657-27-2 72.500
L-Methionine 63-68-3 15.000
L-Phenylalanine 63-91-2 32.000
L-Threonine 72-19-5 48.000
L-Tryptophan 73-22-3 10.000
L-Tyrosine disodium salt 69847-45-6 51.900
L-Valine 72-18-4 46.000
Component CAS Number mg/L
VITAMINS
Choline chloride 67-48-1 1.000
D-Ca-Pantothenate 137-08-6 1.000
Folic acid 59-30-3 1.000
Niacinamide 98-92-0 1.000
Pyridoxine hydrochloride 58-56-0 1.000
Riboflavin 83-88-5 0.100
Thiamine hydrochloride 67-03-8 1.000
OTHERS
i-Inositol 87-89-8 2.000
D-Glucose 50-99-7 4500.000
HEPES 7365-45-9 5958.000
Phenol red sodium salt 34487-61-1 11.000
Sodium Pyruvate 113-24-6 110.000
Customization: pH, glucose, salt balance, HEPES, and full nutrient profile available on request. Contact support@diagnocine.com.
Quality Assurance

ISO 13485:2016 manufacturing & compliance

Manufactured under ISO 13485:2016 QMS with final packaging, testing, and customization at Diagnocine Precision in Totowa, New Jersey, USA.

verified

ISO 13485:2016 QMS

Full quality management system certification covering manufacturing, testing, and release for every production batch.

water_drop

Ultrapure Type 1 Water

All media prepared with 18.2 MΩ·cm resistivity water under strict trace-metal and organic-carbon (TOC) control.

biotech

ISO Class 5 Fill & Finish

Aseptic filling in validated ISO Class 5 laminar-flow workstations; 21 CFR Part 820 (QMSR) aligned.

assignment

Micro-Batch Precision

Small-batch manufacturing supports lot-to-lot nutrient consistency for reproducible perfusion studies.

Endotoxin — USP <85> BET

LAL assay performed on every manufacturing batch prior to release. Release specification: < 0.05 EU/mL; assay sensitivity 0.005 EU/mL.

Particulate — USP <788> Method 1

Light obscuration particle count confirms ≥10 µm and ≥25 µm compliance per batch.

Osmolality — USP <785>

Freezing-point osmometry per USP <785>. Result: See CoA.

Documentation — CoA & Full Lot Records

Certificate of Analysis with full QC panel, traceability, and release signatures for every batch.

Batch-level quality control. Endotoxin is controlled per manufacturing batch rather than per unit. Every batch is tested before release and must meet the release specification:
  • Endotoxin — LAL assay, USP <85> Bacterial Endotoxins Test; assay sensitivity 0.005 EU/mL; release specification < 0.05 EU/mL
  • pH, osmolality, conductivity, appearance and clarity
  • Sterility
A Certificate of Analysis is available on request via support@diagnocine.com.
Product Comparison

How DCP-MEMGH-N1X (FluxMPS™) compares

Side-by-side comparison against conventional 0.22 µm-filtered MEM High Glucose alternatives.

Parameter DCP-MEMGH-N1X (FluxMPS™) Conventional MEM High Glucose (0.22 µm) Standard MEM High Glucose alternative
Grade Microfluidics Suitable Not designated Not designated
Formulation Contains: L-Glutamine, Sodium Bicarbonate, Phenol Red, HEPES, Calcium, Magnesium, Glucose, Sodium Pyruvate Standard MEM High Glucose formulation MEM High Glucose equivalent formulation
Final filtration pore size 0.04 µm 0.22 µm 0.22 µm
Number of filtration stages 4 stages 1 stage 1–2 stages
Mycoplasma barrier filtration check_circle cancel cancel
Endotoxin (release specification) < 0.05 EU/mL Corning classical liquid media — < 0.25 EU/mL
Sigma-Aldrich DMEM complete medium — ≤ 2 EU/mL
Gibco classical DMEM — Not specified (recorded per lot)
USP particulate compliance check_circle USP <788> Method 1 cancel cancel
Water quality Ultrapure Type 1 (18.2 MΩ) Purified water Purified water
Manufacturing QMS ISO 13485:2016 Variable Variable
Microfluidic channel compatibility check_circle Validated cancel Risk of clogging cancel Risk of clogging
Custom formulation check_circle On request cancel Limited

Comparison figures from published supplier specifications, accessed 2026-09-02. Suppliers that publish no numeric endotoxin specification are shown as "Not specified".

FAQ

Frequently asked questions

Common questions about FluxMPS™ Minimum Essential Medium (MEM), High Glucose & 25mM HEPES: 1X Liquid and Microfluidics Suitable cell culture media.

Yes. DCP-MEMGH-N1X uses our Quadruple-stage filtration (0.1 µm ×2 + 0.04 µm ×2), delivering ultra-low particulate counts that reduce microchannel clogging risk in OoC and MPS devices.
Standard 0.22 µm filtration leaves intact mycoplasma-sized organisms (0.2–0.3 µm) and subvisible particulates that accumulate in microchannels. FluxMPS™ uses four sequential stages (0.1 µm → 0.04 µm → 0.1 µm → 0.04 µm) reaching a 0.04 µm final cut-off, delivering approximately 5× lower particulate counts per USP <788> Method 1 (light obscuration).
The 4.5 g/L (4500 mg/L) glucose level supports metabolically demanding cell types including HeLa, MCF-7, fibroblasts, and high-density suspension cultures. If your cell type requires lower glucose, contact support@diagnocine.com for a custom formulation.
This formulation is HEPES-buffered, reducing CO2 dependency. Standard 5–10% CO2 incubation remains compatible.
Yes. FluxMPS™ Minimum Essential Medium (MEM), High Glucose & 25mM HEPES: 1X Liquid can be supplemented with FBS (5–20%), growth factors, antibiotics, or other additives per standard practice. If sterile-filtering any supplement stock before addition, use a 0.2 µm low-protein-binding PES or PVDF membrane — never 0.04 µm, which retains serum proteins and lipoproteins. Add supplements immediately before use.
Every manufacturing batch is tested by LAL assay per USP <85> BET (assay sensitivity 0.005 EU/mL) prior to release. Release specification: < 0.05 EU/mL. Batch-specific results are documented in the Certificate of Analysis, available from support@diagnocine.com.
Yes. A batch-specific CoA is available for every shipment and includes: appearance, pH (USP <791>), osmolality (USP <785>), endotoxin (USP <85> BET), sterility (USP <71>), particulate matter (USP <788> Method 1), raw material traceability, manufacturing date, and authorized release signatures. Request via support@diagnocine.com.
Scientific References

Supporting literature

Peer-reviewed publications supporting Microfluidics Suitable ultra-filtered media and microfluidic cell culture applications.

  1. Huh D et al. (2010). Reconstituting organ-level lung functions on a chip. Science, 328(5986), 1662–1668. doi:10.1126/science.1188302
  2. Bhatia SN & Ingber DE (2014). Microfluidic organs-on-chips. Nature Biotechnology, 32(8), 760–772. doi:10.1038/nbt.2989
  3. Eagle H (1959). Amino acid metabolism in mammalian cell cultures. Science, 130(3373), 432–437. doi:10.1126/science.130.3373.432
  4. Warburg O (1956). On the origin of cancer cells. Science, 123(3191), 309–314. doi:10.1126/science.123.3191.309
  5. Bhattacharya S et al. (2018). Challenges in maintaining cell viability during microfluidic experiments. Electrophoresis, 39(7), 997–1006. doi:10.1002/elps.201700375
  6. Zhang YS et al. (2017). Multisensor-integrated organs-on-chips for automated in situ monitoring. PNAS, 114(12), E2293–E2302. doi:10.1073/pnas.1612906114
  7. Vernetti L et al. (2017). Functional coupling of human microphysiology systems. Scientific Reports, 7, 42296. doi:10.1038/srep42296
  8. Esch EW et al. (2015). Organs-on-chips at the frontiers of drug discovery. Nature Reviews Drug Discovery, 14(4), 248–260. doi:10.1038/nrd4539
  9. Zheng F et al. (2021). Organ-on-a-chip systems: microengineering to biomimic living systems. Small, 17(7), 2004175. doi:10.1002/smll.202004175

Satisfaction
Quality Rating
Value Rating
Style Rating
X