FluxMPS™ Minimum Essential Medium (MEM), High Glucose, NEAA w/o Phenol Red: 1X Liquid

Product#: DCP-MEMG-R1X
$44.00
DCP-MEMG-R1X
Availability:
Ships in 1-2 Weeks

warning For Research Use Only (RUO). Not intended for clinical, diagnostic, or therapeutic use in humans.
ISO 13485 Certified Manufacturing

FluxMPS™ Minimum Essential Medium (MEM), High Glucose, NEAA w/o Phenol Red: 1X Liquid

Contains L-Glutamine Contains Sodium Bicarbonate Contains Calcium Contains Magnesium Contains Glucose Contains Sodium Pyruvate Without Phenol Red Without HEPES

FluxMPS™ Minimum Essential Medium (MEM), High Glucose, NEAA w/o Phenol Red: 1X Liquid is a Microfluidics Suitable, quadruple-stage ultra-filtered (0.1 µm ×2 + 0.04 µm ×2) 1X liquid cell culture medium engineered for organ-on-a-chip (OoC), tissue-on-a-chip (ToC), and microphysiological system (MPS) applications. The high-glucose, NEAA-supplemented, phenol red-free formulation is processed through a validated four-stage filtration train reaching a 0.04 µm final cut-off, delivering microchannel-safe purity for demanding perfusion and imaging workflows.

  • High glucose (4.5 g/L) formulation with Non-Essential Amino Acids (NEAA) — supports high-energy-demand cell types including HeLa, MCF-7 and fibroblasts
  • Quadruple-stage filtration train: 0.1 µm → 0.04 µm → 0.1 µm → 0.04 µm, reaching a 0.04 µm final cut-off
  • Phenol red-free formulation containing 292 mg/L L-glutamine and 110 mg/L sodium pyruvate
  • Endotoxin release specification: < 0.05 EU/mL (LAL, USP <85>), tested per manufacturing batch
  • Prepared with Ultrapure Type 1 water (18.2 MΩ·cm) and filled in an ISO Class 5 aseptic environment
  • Manufactured under an ISO 13485:2016 quality management system; final QC and packaging at Diagnocine, Totowa, NJ
  • Custom formulations available — pH, glucose, salts, HEPES, and nutrient composition on request
DCP-MEMG-R1X | Cell Culture Media UNSPSC: 41116155 | Commodity: Molecular biology and cell culture growth media | (UNv260801)
Minimum Essential Medium (MEM), High Glucose, NEAA w/o Phenol Red: 1X Liquid
  • Glucose4500 mg/L (4.5 g/L)
  • L-Glutamine292 mg/L
  • Sodium Pyruvate110 mg/L
  • HEPESNot added
  • NEAAIncluded
  • pH (USP <791>)7.4
  • Osmolality (USP <785>)See Certificate of Analysis
  • Endotoxin (USP <85>)< 0.05 EU/mL
  • Filtration0.1 µm ×2 + 0.04 µm ×2 (4 stages)
  • Shelf Life12 months from date of manufacture, unopened
ISO 13485:2016 USP <85> <785> <788> RUO
Why FluxMPS™

Engineered where standard media fails

Conventional 0.22 µm-filtered media carry mycoplasma-sized particulates (0.2–0.3 µm), subvisible debris, and batch-to-batch endotoxin variability that accumulate inside microchannels — corrupting biosensor readings, stressing primary cultures, and shortening device lifetimes. FluxMPS™ is built to remove these failure modes at the filtration stage.

filter_alt

Microchannel-safe purity

0.04 µm final filter retains particulates down to sub-mycoplasma size; USP <788> Method 1 (light obscuration) particulate testing performed per lot.

target

High-glucose metabolic support

4.5 g/L glucose plus NEAA supports high-energy-demand cell types including HeLa, MCF-7, fibroblasts, and iPSC-derived models in perfusion devices.

water_drop

Ultrapure-grade water

Prepared with Type 1 water (18.2 MΩ·cm), supporting low trace-metal and organic-carbon background in the finished formulation.

visibility

Low background for imaging

Ultra-low particulate baseline from quadruple-stage filtration supports confocal microscopy, live-cell biosensors, and TEER measurements without particulate interference.

science

Rich, stable nutrient profile

NEAA-supplemented formulation plus micro-batch precision manufacturing ensures comprehensive amino acid coverage for demanding cell culture models.

tune

Customization on demand

pH, glucose, salts, HEPES, and full nutrient composition available on request. Contact support@diagnocine.com.

Purity Architecture

Quadruple-stage filtration system

FluxMPS™ Minimum Essential Medium (MEM), High Glucose, NEAA w/o Phenol Red: 1X Liquid is processed through a validated four-stage filtration train — two dedicated prefilter and final-filter pairs — reaching a 0.04 µm final pore size.

  1. 1

    0.1 µm Prefiltration I

    Removes large particulates, cell debris and protein aggregates; protects the first 0.04 µm cartridge.

  2. 2

    0.04 µm Final filtration I

    First 0.04 µm pass; retains sub-micron particulates and microaggregates that pass through a standard 0.22 µm filter.

  3. 3

    0.1 µm Prefiltration II

    Second dedicated prefilter, protecting the second 0.04 µm cartridge from loading and extending its usable life.

  4. 4

    0.04 µm Final filtration II — Polish

    Ultimate polishing filter; aseptic fill & finish performed in a validated ISO Class 5 laminar-flow workstation.

Performance vs. conventional media

Two paired prefilter/final-filter stages reaching a 0.04 µm final cut-off provide redundant, mycoplasma-retentive-grade filtration beyond what single-pass 0.22 µm filtration can achieve.

4
Sequential filtration passes (0.1 µm ×2 + 0.04 µm ×2)
0.04
µm final filter pore size
Sterility assurance: Every lot undergoes 14-day USP <71> sterility testing. Mycoplasma risk is controlled by the 0.1 µm mycoplasma-retentive filtration stages within this train (not tested per lot).
Grade: This product is Microfluidics Suitable, filtered to a 0.04 µm final cut-off. It is not an MPS Grade product — that designation is reserved for the 0.01 µm ultra nano-filtered line, which adds 0.02 µm and 0.01 µm stages after the 0.04 µm polish. For applications requiring the 0.01 µm cut-off, contact support@diagnocine.com.
FluxMPS™ Minimum Essential Medium (MEM), High Glucose, NEAA w/o Phenol Red: 1X Liquid (DCP-MEMG-R1X) Quadruple-stage filtration system: 0.1 micron Prefiltration I, 0.04 micron Final filtration I, 0.1 micron Prefiltration II, 0.04 micron Final filtration II Polish for organ-on-a-chip and microfluidic applications by Diagnocine
Figure 1. FluxMPS™ Quadruple-stage filtration architecture (0.1 µm ×2 + 0.04 µm ×2) delivering Microfluidics Suitable purity for MPS and OoC applications.
© Diagnocine® — DCP-MEMG-R1X
Applications

Designed for next-generation cell culture platforms

FluxMPS™ Minimum Essential Medium (MEM), High Glucose, NEAA w/o Phenol Red: 1X Liquid is validated for organ-on-a-chip, cancer biology, stem cell, vascular, metabolic, and live-cell imaging applications where particulate load and endotoxin variability are unacceptable.

Automated Bioreactors & Robotics

Next-Generation System Uptime

An optional 0.01 µm (10 nm) ultra nano-filtered MPS Grade variant of this formulation is available for automated bioreactor and robotic perfusion systems requiring the most stringent particulate exclusion.

  • Total Particulate Exclusion: 10 nm filtration for nanoscale valve and sensor protection
  • Valve & Sensor Protection: prevents particulate-induced blockage in precision fluidic systems
  • Extended Perfusion Stability: maintains flow rate consistency across multi-week automated runs

Inquiry Required: Contact support@diagnocine.com to request the 0.01 µm MPS Grade variant.

Microfluidics

Micro Physiological System (MPS) & Chip

Quadruple-stage filtered formulation helps prevent microchannel clogging and supports laminar flow integrity across complex chip geometries.

OoCToCBoCLoCMPS
Cancer Biology

Warburg Effect & Metabolic Research

High-glucose base (4.5 g/L) supports Warburg effect studies and glucose uptake assays in cancer cell lines.

MCF-7MDA-MB-231HeLaHT-1080
Stem Cell Biology

iPSC-Derived Models

Ultra-filtered formulation supports sensitive iPSC differentiation protocols where endotoxin variability causes off-target effects.

iPSC-NeuronsiPSC-CMiPSC-Hep
Vascular Biology

Endothelial & Primary Cells

Microchannel-safe purity supports endothelial barrier integrity and TEER measurements in perfusion models.

HUVECsBHK-21Primary fibroblasts
Metabolomics

Metabolic Flux Analysis

High-glucose base enables precise ¹³C isotope tracing and glycolytic flux experiments. Not compatible with Agilent Seahorse XF assays, which require bicarbonate-free, phenol red-free medium.

13C tracingNMR metabolomics
Live-Cell Imaging

Microscopy & Optical Sensing

Ultra-low particulate load supports high-content confocal imaging and optical biosensor integration.

ConfocalBiosensorsTEER
Technical Specifications

Lot-release quality parameters

Every production lot of FluxMPS™ Minimum Essential Medium (MEM), High Glucose, NEAA w/o Phenol Red: 1X Liquid undergoes the quality-release battery below before shipment.

Physical & Chemical Parameters
Parameter Specification
Formulation Contains: L-Glutamine, Sodium Bicarbonate, Calcium, Magnesium, Glucose, Sodium Pyruvate. Without: Phenol Red, HEPES.
Appearance Colorless to pale yellow, clear solution
pH USP <791> 7.4
Osmolality USP <785> See Certificate of Analysis
Glucose 4500 mg/L (4.5 g/L)
L-Glutamine 292 mg/L
Sodium Pyruvate 110 mg/L
Phenol Red Not added
Sterility, Purity & Safety Parameters
Parameter Specification
Endotoxin USP <85> BET < 0.05 EU/mL (batch release specification)
Sterility USP <71> No growth after 14 days
Mycoplasma 0.1 µm mycoplasma-retentive filtration (not tested per lot)
Particulate ≥10 µm USP <788> Method 1 Compliant
Particulate ≥25 µm USP <788> Method 1 Compliant
Water purity Ultrapure Type 1, 18.2 MΩ·cm
Manufacturing std. ISO 13485 ISO 13485:2016
Fill environment ISO Class 5 (Class 100)
Storage, Handling & Logistics
Parameter Specification
Storage temperature 2-8°C, protected from light
Freeze-thaw Not recommended
Shelf life 12 months from date of manufacture, unopened
Shipping condition Cold pack
CO2 requirement Approximately 5-6% CO2 (derived from 2200 mg/L NaHCO3 bicarbonate at pH 7.4)
Raw Materials & Regulatory Traceability
Parameter Specification
Raw material grade Cell culture / reagent grade
Traceability Full lot documentation, CoA available
Manufacturing QMS ISO 13485:2016 certified
UNSPSC 41116155 — Molecular biology and cell culture growth media (UNv260801)
Regulatory alignment 21 CFR Part 820 (QMSR) aligned
Production method Micro-batch precision manufacturing
Intended use For Research Use Only (RUO)
Available pack sizes: 500 mL, 1000 mL.
Formulation

Full composition (mg/L)

Complete formulation with CAS numbers, reproduced from the manufacturing specification. Total: 36 components. Custom compositions available on request.

Component CAS Number mg/L
INORGANIC SALTS
Calcium chloride dihydrate 10035-04-8 265.000
Magnesium sulfate anhydrous 7487-88-9 97.720
Potassium chloride 7447-40-7 400.000
Sodium bicarbonate 144-55-8 2200.000
Sodium chloride 7647-14-5 6800.000
Sodium dihydrogen phosphate anhydrous 7558-80-7 122.000
Component CAS Number mg/L
AMINO ACIDS
Glycine 56-40-6 7.500
L-Alanine 56-41-7 8.900
L-Arginine hydrochloride 1119-34-2 126.000
L-Asparagine monohydrate   15.000
L-Aspartic acid 56-84-8 13.300
L-Cystine dihydrochloride 30189-89-0 31.300
L-Glutamic acid 56-86-0 14.700
L-Glutamine 56-85-9 292.000
L-Histidine hydrochloride monohydrate 5934-29-2 42.000
L-Isoleucine 73-32-5 52.000
L-Leucine 61-90-5 52.000
L-Lysine hydrochloride 657-27-2 72.500
L-Methionine 63-68-3 15.000
L-Phenylalanine 63-91-2 32.000
L-Proline 147-85-3 11.500
L-Serine 56-45-1 10.500
L-Threonine 72-19-5 48.000
L-Tryptophan 73-22-3 10.000
L-Tyrosine disodium salt dihydrate   51.900
L-Valine 72-18-4 46.000
Component CAS Number mg/L
VITAMINS
Choline chloride 67-48-1 1.000
D-Ca-Pantothenate 137-08-6 1.000
Folic acid 59-30-3 1.000
Nicotinamide 98-92-0 1.000
Pyridoxal hydrochloride 65-22-5 1.000
Riboflavin 83-88-5 0.100
Thiamine hydrochloride 67-03-8 1.000
i-Inositol 87-89-8 2.000
OTHERS
D-Glucose 50-99-7 4500.000
Sodium pyruvate 113-24-6 110.000
Customization: pH, glucose, salt balance, HEPES, and full nutrient profile available on request. Contact support@diagnocine.com.
Quality Assurance

ISO 13485:2016 manufacturing & compliance

Manufactured under an ISO 13485:2016 quality management system, with final packaging, testing, and customization at Diagnocine, Totowa, New Jersey, USA.

verified

ISO 13485:2016 QMS

Full quality management system certification covering manufacturing, testing, and release for every production lot.

water_drop

Ultrapure Type 1 Water

All media prepared with 18.2 MΩ·cm resistivity water.

biotech

ISO Class 5 Fill & Finish

Aseptic filling performed in a validated ISO Class 5 laminar-flow workstation.

assignment

Micro-Batch Precision

Small-batch manufacturing supports lot-to-lot nutrient consistency for reproducible perfusion studies.

Endotoxin — USP <85> BET

LAL assay per batch. Release specification: < 0.05 EU/mL.

Particulate — USP <788> Method 1

Light obscuration particle count confirms ≥10 µm and ≥25 µm compliance per lot.

Osmolality — USP <785>

Freezing-point osmometry per USP <785>. Result: see Certificate of Analysis.

Documentation — CoA & Full Lot Records

Certificate of Analysis with full QC panel, traceability, and release signatures for every lot.

Batch-level quality control. Endotoxin is controlled per manufacturing batch rather than per unit. Every batch is tested before release and must meet the release specification:
  • Endotoxin — LAL assay, USP <85> Bacterial Endotoxins Test; assay sensitivity 0.005 EU/mL; release specification < 0.05 EU/mL
  • pH, osmolality, conductivity, appearance and clarity
  • Sterility
A Certificate of Analysis is available on request via support@diagnocine.com.
Product Comparison

How DCP-MEMG-R1X (FluxMPS™) compares

Side-by-side comparison against conventional 0.22 µm-filtered MEM High Glucose alternatives and published supplier endotoxin specifications.

Parameter DCP-MEMG-R1X (FluxMPS™) Conventional MEM High Glucose (0.22 µm) Standard MEM High Glucose alternative
Grade Microfluidics Suitable Not specified Not specified
Formulation Contains: L-Glutamine, Sodium Bicarbonate, Calcium, Magnesium, Glucose, Sodium Pyruvate. Without: Phenol Red, HEPES. MEM High Glucose Standard MEM High Glucose Equivalent
Final filtration pore size 0.04 µm 0.22 µm 0.22 µm
Number of filtration stages 4 stages 1 stage 1–2 stages
Mycoplasma-retentive filtration check_circle cancel cancel
Endotoxin (release specification) FluxMPS™ — < 0.05 EU/mL Corning classical liquid media — < 0.25 EU/mL
Sigma-Aldrich DMEM complete medium — ≤ 2 EU/mL
Gibco classical DMEM — Not specified (recorded per lot)
Not specified
USP particulate compliance check_circle USP <788> Method 1 cancel cancel
Water quality Ultrapure Type 1 (18.2 MΩ·cm) Purified water Purified water
Manufacturing QMS ISO 13485:2016 Variable Variable
Microfluidic channel compatibility check_circle Validated cancel Risk of clogging cancel Risk of clogging
Custom formulation check_circle On request cancel Limited

Comparison figures from published supplier specifications, accessed 2026-09-02. Suppliers that publish no numeric endotoxin specification are shown as "Not specified".

FAQ

Frequently asked questions

Common questions about FluxMPS™ Minimum Essential Medium (MEM), High Glucose, NEAA w/o Phenol Red: 1X Liquid and Microfluidics Suitable cell culture media.

Yes. DCP-MEMG-R1X uses our quadruple-stage filtration train (0.1 µm ×2 + 0.04 µm ×2), delivering ultra-low particulate counts that help prevent microchannel clogging in OoC and MPS devices.
Standard 0.22 µm filtration does not retain mycoplasma-sized particulates (0.2–0.3 µm). FluxMPS™ runs two paired prefilter/final-filter stages reaching 0.04 µm, with USP <788> Method 1 (light obscuration) particulate testing performed per lot.
The 4.5 g/L (4500 mg/L) glucose level supports metabolically demanding cell types including HeLa, MCF-7, fibroblasts, and high-density suspension cultures. If your cell type requires a lower glucose concentration, contact support@diagnocine.com for a custom formulation.
Yes. This formulation contains 2200 mg/L sodium bicarbonate, which requires approximately 5–6% CO2 to maintain pH 7.4.
Yes. FluxMPS™ Minimum Essential Medium (MEM), High Glucose, NEAA w/o Phenol Red: 1X Liquid can be supplemented with FBS (5–20%), growth factors, antibiotics, or other additives per standard practice. Filter serum-containing or protein-containing supplements through a 0.2 µm low-protein-binding PES or PVDF membrane before addition; add supplements immediately before use.
Endotoxin is controlled per manufacturing batch. Every batch is tested by LAL assay per USP <85> Bacterial Endotoxins Test (assay sensitivity 0.005 EU/mL) and must meet the release specification of < 0.05 EU/mL before shipment. Lot-specific results are documented in the Certificate of Analysis, available from support@diagnocine.com.
Yes. A lot-specific CoA is available for every shipment and includes: appearance, pH (USP <791>), osmolality (USP <785>), endotoxin (USP <85> BET), sterility (USP <71>), particulate matter (USP <788> Method 1), raw material traceability, manufacturing date, lot number, expiry, and authorized release signatures. Request via support@diagnocine.com.
Scientific References

Supporting literature

Peer-reviewed publications supporting ultra-filtered, Microfluidics Suitable media and microfluidic cell culture applications.

  1. Huh D et al. (2010). Reconstituting organ-level lung functions on a chip. Science, 328(5986), 1662–1668. doi:10.1126/science.1188302
  2. Bhatia SN & Ingber DE (2014). Microfluidic organs-on-chips. Nature Biotechnology, 32(8), 760–772. doi:10.1038/nbt.2989
  3. Eagle H (1959). Amino acid metabolism in mammalian cell cultures. Science, 130(3373), 432–437. doi:10.1126/science.130.3373.432
  4. Warburg O (1956). On the origin of cancer cells. Science, 123(3191), 309–314. doi:10.1126/science.123.3191.309
  5. Bhattacharya S et al. (2018). Challenges in maintaining cell viability during microfluidic experiments. Electrophoresis, 39(7), 997–1006. doi:10.1002/elps.201700375
  6. Zhang YS et al. (2017). Multisensor-integrated organs-on-chips for automated in situ monitoring. PNAS, 114(12), E2293–E2302. doi:10.1073/pnas.1612906114
  7. Vernetti L et al. (2017). Functional coupling of human microphysiology systems. Scientific Reports, 7, 42296. doi:10.1038/srep42296
  8. Esch EW et al. (2015). Organs-on-chips at the frontiers of drug discovery. Nature Reviews Drug Discovery, 14(4), 248–260. doi:10.1038/nrd4539
  9. Zheng F et al. (2021). Organ-on-a-chip systems: microengineering to biomimic living systems. Small, 17(7), 2004175. doi:10.1002/smll.202004175

Satisfaction
Quality Rating
Value Rating
Style Rating
X