FluxMPS™ Minimum Essential Medium (MEM), High Glucose, NEAA & 25mM HEPES: 1X Liquid

Product#: DCP-MEMGH1X
$49.50
DCP-MEMGH1X
Availability:
Ships in 1-2 Weeks

warning For Research Use Only (RUO). Not intended for clinical, diagnostic, or therapeutic use in humans.
ISO 13485 Certified Manufacturing

FluxMPS™ Minimum Essential Medium (MEM), High Glucose, NEAA & 25mM HEPES: 1X Liquid

Contains L-Glutamine Contains Sodium Bicarbonate Contains Phenol Red Contains HEPES Contains Calcium Contains Magnesium Contains Glucose Contains Sodium Pyruvate

FluxMPS™ Minimum Essential Medium (MEM), High Glucose, NEAA & 25mM HEPES: 1X Liquid is a Microfluidics Suitable, quadruple-stage ultra-filtered (0.1 µm ×2 + 0.04 µm ×2) 1X liquid cell culture medium engineered for organ-on-a-chip (OoC), tissue-on-a-chip (ToC), and microphysiological system (MPS) applications. A quadruple-stage train (0.1 µm ×2 + 0.04 µm ×2) reaches a 0.04 µm final cut-off, five times finer than the 0.22 µm membranes used for conventional sterile filtration.

  • High glucose (4.5 g/L) formulation with Non-Essential Amino Acids (NEAA) — supports high-energy-demand cell types in microfluidic and OoC perfusion systems
  • Quadruple-stage filtration train: 0.1 µm (Prefiltration I) → 0.04 µm (Final filtration I) → 0.1 µm (Prefiltration II) → 0.04 µm (Final filtration II — Polish)
  • Endotoxin release specification: < 0.05 EU/mL (USP <85> BET), controlled per manufacturing batch
  • 25 mM HEPES buffering alongside 2200 mg/L sodium bicarbonate — reduced CO₂ dependency, compatible with standard 5% CO₂ incubation
  • pH 7.4 (USP <791>); phenol red present as a visual pH indicator (11 mg/L)
  • Prepared with Ultrapure Type 1 water (18.2 MΩ·cm) under ISO Class 5 aseptic fill & finish
  • Manufactured under an ISO 13485:2016 quality management system; final packaging and QC at Diagnocine, Totowa, NJ
  • Custom formulations available — pH, glucose, salts, HEPES, and nutrient composition on request (support@diagnocine.com)
DCP-MEMGH1X | Cell Culture Media UNSPSC: 41116155 | Commodity: Molecular biology and cell culture growth media | (UNv260801)
Minimum Essential Medium (MEM), High Glucose, NEAA & 25mM HEPES: 1X Liquid
  • Glucose4500 mg/L (4.5 g/L)
  • HEPES5958 mg/L (25 mM)
  • L-Glutamine292 mg/L
  • Sodium Pyruvate110 mg/L
  • NEAAIncluded
  • pH (USP <791>)7.4
  • Endotoxin (USP <85>)< 0.05 EU/mL
  • Filtration0.1 µm ×2 + 0.04 µm ×2
  • Storage2–8°C, protected from light
  • Shelf Life12 months from date of manufacture, unopened
ISO 13485:2016 USP <85> <785> <788> RUO
Why FluxMPS™

Engineered where standard media fails

Conventional 0.22 µm-filtered media carry mycoplasma-sized particulates (0.2–0.3 µm), subvisible debris, and batch-to-batch endotoxin variation that accumulate inside microchannels — corrupting biosensor readings, triggering inflammation in primary cultures, and shortening device lifetimes. FluxMPS™ is built to reduce these failure modes at the source.

filter_alt

Microchannel-safe purity

0.04 µm final filter retains particles to sub-mycoplasma size; USP <788> Method 1 (light obscuration) particulate compliance verified per lot.

target

High-glucose metabolic support

4.5 g/L glucose supports high-energy-demand cell types including HeLa, MCF-7, fibroblasts, and iPSC-derived models in perfusion devices.

water_drop

Ultrapure-grade water

Prepared with Type 1 water (18.2 MΩ·cm) under strict trace-metal and total organic carbon (TOC) control, supporting reproducible biosensor and imaging assays.

visibility

Low background for imaging

Ultra-low particulate baseline reduces background scatter for confocal microscopy, live-cell biosensors, and TEER measurements.

science

Rich, stable nutrient profile

NEAA-supplemented formulation plus micro-batch precision ensures comprehensive amino acid coverage for demanding cell culture models.

tune

Customization on demand

pH, glucose, salts, HEPES, and full nutrient composition available on request. Contact support@diagnocine.com.

Purity Architecture

Quadruple-stage filtration system

FluxMPS™ Minimum Essential Medium (MEM), High Glucose, NEAA & 25mM HEPES: 1X Liquid is processed through a four-stage serial filtration sequence — two paired prefilter/final-filter passes — reaching a 0.04 µm final cut-off, addressing mycoplasma-scale and subvisible particulates that 0.22 µm filtration cannot retain.

  1. 1

    0.1 µm Prefiltration I

    Removes large particulates, cell debris, and protein aggregates; protects the first 0.04 µm final-filter cartridge.

  2. 2

    0.04 µm Final filtration I

    First 0.04 µm pass; retains sub-micron particulates and microaggregates, including mycoplasma-sized organisms (0.2–0.3 µm), that pass a 0.22 µm filter.

  3. 3

    0.1 µm Prefiltration II

    Second dedicated prefilter, protecting the second 0.04 µm final-filter cartridge from breakthrough particulates.

  4. 4

    0.04 µm Final filtration II — Polish

    Ultimate polishing filter; aseptic fill performed in a validated ISO Class 5 laminar-flow workstation.

Performance vs. conventional media

Four sequential stages reaching 0.04 µm deliver approximately 5× cleaner media by particulate count compared to single-pass 0.22 µm filtration, with USP <788> Method 1 compliance verified on every production lot.

5×
 
0.04
µm final filter pore size across 4 sequential passes
Sterility assurance: Every lot undergoes 14-day USP <71> sterility testing; no bacterial or fungal growth observed. Mycoplasma risk is mitigated by the 0.1 µm mycoplasma-retentive filtration stages described above (not tested per lot).
Grade: This product is Microfluidics Suitable, filtered to a 0.04 µm final cut-off. It is not an MPS Grade product — that designation is reserved for the 0.01 µm ultra nano-filtered line, which adds 0.02 µm and 0.01 µm stages after the 0.04 µm polish. For applications requiring the 0.01 µm cut-off, contact support@diagnocine.com.
FluxMPS™ Minimum Essential Medium (MEM), High Glucose, NEAA & 25mM HEPES: 1X Liquid (DCP-MEMGH1X) Quadruple-stage filtration system: 0.1 micron Prefiltration I, 0.04 micron Final filtration I, 0.1 micron Prefiltration II, 0.04 micron Final filtration II Polish, for organ-on-a-chip and microfluidic applications by Diagnocine
Figure 1. FluxMPS™ Quadruple-stage filtration architecture (0.1 µm ×2 + 0.04 µm ×2) delivering a 0.04 µm purity baseline for MPS and OoC applications.
© Diagnocine® — DCP-MEMGH1X
Applications

Designed for next-generation cell culture platforms

FluxMPS™ Minimum Essential Medium (MEM), High Glucose, NEAA & 25mM HEPES: 1X Liquid is validated for organ-on-a-chip, cancer biology, metabolic research, live-cell imaging, and primary cell models where particulate contamination and endotoxin variation are unacceptable.

Automated Bioreactors & Robotics

Next-Generation System Uptime

An optional MPS Grade 0.01 µm (10 nm) ultra nano-filtered variant is available for automated bioreactor and robotic perfusion systems requiring the ultimate particulate exclusion.

  • Total Particulate Exclusion: 10 nm filtration for nanoscale valve and sensor protection
  • Valve & Sensor Protection: prevents particulate-induced blockage in precision fluidic systems
  • Extended Perfusion Stability: maintains flow rate consistency across multi-week automated runs

Inquiry Required: Contact support@diagnocine.com to request the MPS Grade 0.01 µm variant.

Microfluidics

Micro Physiological System (MPS) & Chip

Ultra-filtered formulation supports laminar flow integrity across complex chip geometries and reduces microchannel clogging risk.

OoCToCBoCLoCMPS
Cancer Biology

Warburg Effect & Metabolic Research

High-glucose base supports Warburg effect studies and glucose uptake assays in cancer cell lines.

MCF-7MDA-MB-231HeLaHT-1080
Stem Cell Biology

iPSC-Derived Models

Batch-tested low-endotoxin formulation supports sensitive iPSC differentiation protocols.

iPSC-NeuronsiPSC-CMiPSC-Hep
Vascular Biology

Endothelial & Primary Cells

Microchannel-safe purity supports endothelial barrier integrity and TEER measurements in perfusion models.

HUVECsBHK-21Primary fibroblasts
Metabolomics

Metabolic Flux Analysis

High-glucose base enables precise ¹³C isotope tracing and glycolytic flux experiments. Not compatible with Agilent Seahorse XF assays, which require bicarbonate-free, phenol red-free medium.

13C tracingNMR metabolomics
Live-Cell Imaging

Microscopy & Optical Sensing

Ultra-low particulate load supports high-content confocal imaging and optical biosensor integration.

ConfocalBiosensorsTEER
Technical Specifications

Lot-release quality parameters

Every production lot of FluxMPS™ Minimum Essential Medium (MEM), High Glucose, NEAA & 25mM HEPES: 1X Liquid undergoes the complete quality-release battery below before shipment.

Physical & Chemical Parameters
Parameter Specification
Formulation Contains: L-Glutamine, Sodium Bicarbonate, Phenol Red, HEPES, Calcium, Magnesium, Glucose, Sodium Pyruvate
Appearance Orange-to-red colored, clear solution (phenol red present)
pH USP <791> 7.4
Osmolality USP <785> See Certificate of Analysis
Glucose 4500 mg/L (4.5 g/L)
L-Glutamine 292 mg/L
Sodium Pyruvate 110 mg/L
Phenol Red 11 mg/L (present)
Sterility, Purity & Safety Parameters
Parameter Specification
Endotoxin USP <85> BET < 0.05 EU/mL (batch-release specification)
Sterility USP <71> No growth after 14 days
Mycoplasma 0.1 µm mycoplasma-retentive filtration (not tested per lot)
Particulate ≥10 µm USP <788> Method 1 Compliant
Particulate ≥25 µm USP <788> Method 1 Compliant
Water Purity Ultrapure Type 1, 18.2 MΩ·cm
Manufacturing std. ISO 13485 ISO 13485:2016
Fill environment ISO Class 5 (Class 100)
Storage, Handling & Logistics
Parameter Specification
Storage temperature 2–8°C, protected from light
Freeze-thaw Not recommended
Shelf life 12 months from date of manufacture, unopened
Shipping condition Cold pack
CO₂ requirement HEPES-buffered (25 mM) with sodium bicarbonate (2200 mg/L); reduced CO₂ dependency — compatible with standard 5% CO₂ incubation
Raw Materials & Regulatory Traceability
Parameter Specification
Raw material grade Cell culture / reagent grade
Traceability Full lot documentation, CoA available
Manufacturing QMS ISO 13485:2016 certified
UNSPSC 41116155 — Molecular biology and cell culture growth media (UNv260801)
Regulatory alignment 21 CFR Part 820 (QMSR) aligned
Production method Micro-batch precision manufacturing
Intended use For Research Use Only (RUO)
Formulation

Full composition (mg/L)

Complete formulation with CAS numbers, reproduced from manufacturer specification — 38 components across 4 categories. Custom compositions available on request.

Component CAS Number mg/L
INORGANIC SALTS
Calcium chloride dihydrate 10035-04-8 265.000
Magnesium sulfate anhydrous 7487-88-9 97.720
Potassium chloride 7447-40-7 400.000
Sodium bicarbonate 144-55-8 2200.000
Sodium chloride 7647-14-5 6800.000
Sodium dihydrogen phosphate anhydrous 7558-80-7 122.000
Component CAS Number mg/L
AMINO ACIDS
Glycine 56-40-6 7.500
L-Alanine 56-41-7 8.900
L-Arginine hydrochloride 1119-34-2 126.000
L-Asparagine monohydrate   15.000
L-Aspartic acid 56-84-8 13.300
L-Cystine dihydrochloride 30189-89-0 31.300
L-Glutamic acid 56-86-0 14.700
L-Glutamine 56-85-9 292.000
L-Histidine hydrochloride monohydrate 5934-29-2 42.000
L-Isoleucine 73-32-5 52.000
L-Leucine 61-90-5 52.000
L-Lysine hydrochloride 657-27-2 72.500
L-Methionine 63-68-3 15.000
L-Phenylalanine 63-91-2 32.000
L-Proline 147-85-3 11.500
L-Serine 56-45-1 10.500
L-Threonine 72-19-5 48.000
L-Tryptophan 73-22-3 10.000
L-Tyrosine disodium salt dihydrate   51.900
L-Valine 72-18-4 46.000
Component CAS Number mg/L
VITAMINS
Choline chloride 67-48-1 1.000
D-Ca-Pantothenate 137-08-6 1.000
Folic acid 59-30-3 1.000
Nicotinamide 98-92-0 1.000
Pyridoxal hydrochloride 65-22-5 1.000
Riboflavin 83-88-5 0.100
Thiamine hydrochloride 67-03-8 1.000
i-Inositol 87-89-8 2.000
OTHERS
D-Glucose 50-99-7 4500.000
HEPES 7365-45-9 5958.000
Phenol red sodium salt 34487-61-1 11.000
Sodium pyruvate 113-24-6 110.000
Customization: pH, glucose, salt balance, HEPES, and full nutrient profile available on request. Contact support@diagnocine.com.
Quality Assurance

ISO 13485:2016 manufacturing & compliance

Manufactured under ISO 13485:2016 QMS with final packaging, testing, and customization at Diagnocine Precision in Totowa, New Jersey, USA.

verified

ISO 13485:2016 QMS

Full quality management system certification covering manufacturing, testing, and release for every production lot.

water_drop

Ultrapure Type 1 Water

All media prepared with 18.2 MΩ·cm resistivity water under strict trace-metal and TOC control.

biotech

ISO Class 5 Fill & Finish

Aseptic filling in validated ISO Class 5 laminar-flow workstations; 21 CFR Part 820 (QMSR) aligned.

assignment

Micro-Batch Precision

Small-batch manufacturing supports lot-to-lot nutrient consistency for reproducible perfusion studies.

Endotoxin — USP <85> BET

LAL assay per batch. Release specification: < 0.05 EU/mL.

Particulate — USP <788> Method 1

Light obscuration particle count confirms ≥10 µm and ≥25 µm compliance per lot.

Osmolality — USP <785>

Freezing-point osmometry per USP <785>. Result: see Certificate of Analysis.

Documentation — CoA & Full Lot Records

Certificate of Analysis with full QC panel, traceability, and release signatures for every lot.

Batch-level quality control. Endotoxin is controlled per manufacturing batch rather than per unit. Every batch is tested before release and must meet the release specification:
  • Endotoxin — LAL assay, USP <85> Bacterial Endotoxins Test; assay sensitivity 0.005 EU/mL; release specification < 0.05 EU/mL
  • pH, osmolality, conductivity, appearance and clarity
  • Sterility
A Certificate of Analysis is available on request via support@diagnocine.com.
Product Comparison

How DCP-MEMGH1X (FluxMPS™) compares

Side-by-side comparison against conventional 0.22 µm-filtered MEM High Glucose alternatives, and against published supplier endotoxin specifications.

Parameter DCP-MEMGH1X (FluxMPS™) Conventional MEM High Glucose (0.22 µm) Standard MEM High Glucose alternative
Grade Microfluidics Suitable (0.04 µm) Not specified Not specified
Formulation L-Glutamine, Sodium Bicarbonate, Phenol Red, HEPES, Calcium, Magnesium, Glucose, Sodium Pyruvate Standard MEM High Glucose MEM High Glucose Equivalent
Final filtration pore size 0.04 µm 0.22 µm 0.22 µm
Number of filtration stages 4 stages (0.1 µm ×2 + 0.04 µm ×2) 1 stage 1–2 stages
Mycoplasma barrier filtration check_circle cancel cancel
Endotoxin (release specification) < 0.05 EU/mL Corning classical liquid media — < 0.25 EU/mL
Sigma-Aldrich DMEM complete medium — ≤ 2 EU/mL
Gibco classical DMEM — Not specified (recorded per lot)
USP particulate compliance check_circle USP <788> Method 1 cancel cancel
Water quality Ultrapure Type 1 (18.2 MΩ) Purified water Purified water
Manufacturing QMS ISO 13485:2016 Variable Variable
Microfluidic channel compatibility check_circle Validated cancel Risk of clogging cancel Risk of clogging
Custom formulation check_circle On request cancel Limited

Comparison figures from published supplier specifications, accessed 2026-09-02. Suppliers that publish no numeric endotoxin specification are shown as "Not specified".

FAQ

Frequently asked questions

Common questions about FluxMPS™ Minimum Essential Medium (MEM), High Glucose, NEAA & 25mM HEPES: 1X Liquid and Microfluidics Suitable cell culture media.

Yes. DCP-MEMGH1X is Microfluidics Suitable, processed through our Quadruple-stage filtration (0.1 µm ×2 + 0.04 µm ×2), delivering ultra-low particulate counts that reduce microchannel clogging risk in OoC and MPS devices.
Standard 0.22 µm filtration leaves intact mycoplasma-sized organisms (0.2–0.3 µm) and subvisible particulates that accumulate in microchannels. FluxMPS™ uses four sequential stages reaching 0.04 µm, delivering approximately 5× lower particulate counts per USP <788> Method 1.
The 4.5 g/L (4500 mg/L) glucose level supports metabolically demanding cell types including HeLa, MCF-7, fibroblasts, and high-density suspension cultures. If your cell type requires lower glucose, contact support@diagnocine.com for a custom formulation.
This formulation is HEPES-buffered (25 mM) alongside sodium bicarbonate (2200 mg/L), giving it reduced CO2 dependency compared to bicarbonate-only formulations. It remains compatible with standard 5% CO2 incubation.
Yes. FluxMPS™ Minimum Essential Medium (MEM), High Glucose, NEAA & 25mM HEPES: 1X Liquid can be supplemented with FBS (5–20%), growth factors, antibiotics, or other additives per standard practice. Add supplements immediately before use. When filtering serum or protein-containing supplements, use a 0.2 µm low-protein-binding PES or PVDF filter — never 0.04 µm, which will strip serum of functional protein and lipoprotein content.
Endotoxin is controlled per manufacturing batch rather than per unit. Every batch is tested by LAL assay (USP <85>, Bacterial Endotoxins Test; assay sensitivity 0.005 EU/mL) before release and must meet the release specification: < 0.05 EU/mL. A Certificate of Analysis with lot-specific documentation is available on request.
Yes. A lot-specific CoA is available for every shipment and includes: appearance, pH (USP <791>), osmolality (USP <785>), endotoxin (USP <85> BET), sterility (USP <71>), particulate matter (USP <788>), raw material traceability, manufacturing date, and authorized release signatures. Request via support@diagnocine.com.
Scientific References

Supporting literature

Peer-reviewed publications supporting Microfluidics Suitable ultra-filtered media and microfluidic cell culture applications.

  1. Huh D et al. (2010). Reconstituting organ-level lung functions on a chip. Science, 328(5986), 1662–1668. doi:10.1126/science.1188302
  2. Bhatia SN & Ingber DE (2014). Microfluidic organs-on-chips. Nature Biotechnology, 32(8), 760–772. doi:10.1038/nbt.2989
  3. Eagle H (1959). Amino acid metabolism in mammalian cell cultures. Science, 130(3373), 432–437. doi:10.1126/science.130.3373.432
  4. Warburg O (1956). On the origin of cancer cells. Science, 123(3191), 309–314. doi:10.1126/science.123.3191.309
  5. Bhattacharya S et al. (2018). Challenges in maintaining cell viability during microfluidic experiments. Electrophoresis, 39(7), 997–1006. doi:10.1002/elps.201700375
  6. Zhang YS et al. (2017). Multisensor-integrated organs-on-chips for automated in situ monitoring. PNAS, 114(12), E2293–E2302. doi:10.1073/pnas.1612906114
  7. Vernetti L et al. (2017). Functional coupling of human microphysiology systems. Scientific Reports, 7, 42296. doi:10.1038/srep42296
  8. Esch EW et al. (2015). Organs-on-chips at the frontiers of drug discovery. Nature Reviews Drug Discovery, 14(4), 248–260. doi:10.1038/nrd4539
  9. Zheng F et al. (2021). Organ-on-a-chip systems: microengineering to biomimic living systems. Small, 17(7), 2004175. doi:10.1002/smll.202004175

Satisfaction
Quality Rating
Value Rating
Style Rating
X