FluxMPS™ Minimum Essential Medium (MEM), Low Glucose & 25mM HEPES w/o L-Glutamine, Sodium Pyruvate, Sodium Bicarbonate: 1X Liquid

Product#: DCP-MEMH-QPBN1X
$44.00
DCP-MEMH-QPBN1X
Availability:
Ships in 1-2 Weeks

warning For Research Use Only (RUO). Not intended for clinical, diagnostic, or therapeutic use in humans.
ISO 13485 Certified Manufacturing

FluxMPS™ Minimum Essential Medium (MEM), Low Glucose & 25mM HEPES w/o L-Glutamine, Sodium Pyruvate, Sodium Bicarbonate: 1X Liquid

Contains Phenol Red Contains HEPES Contains Calcium Contains Magnesium Contains Glucose Without L-Glutamine Without Sodium Bicarbonate Without Sodium Pyruvate

FluxMPS™ Minimum Essential Medium (MEM), Low Glucose & 25mM HEPES w/o L-Glutamine, Sodium Pyruvate, Sodium Bicarbonate: 1X Liquid is a Microfluidics Suitable, quadruple-stage ultra-filtered (0.1 µm ×2 + 0.04 µm ×2) 1X liquid cell culture medium engineered for organ-on-a-chip (OoC), tissue-on-a-chip (ToC), and microphysiological system (MPS) applications. The four-stage train reaches a 0.04 µm final cut-off — five times finer than the 0.22 µm membranes used in conventional single-pass filtration — supporting microchannel-safe perfusion.

  • Low-glucose MEM (1.0 g/L) with 25 mM HEPES buffering; formulated without L-glutamine, sodium pyruvate, or sodium bicarbonate for full user control over supplementation
  • Quadruple-stage filtration train (0.1 µm ×2 + 0.04 µm ×2) reaching a 0.04 µm final cut-off, verified per lot
  • Endotoxin release specification: < 0.05 EU/mL (LAL assay, USP <85> BET)
  • HEPES-buffered, bicarbonate-free formulation supports reduced CO2 dependence in culture systems (validate per cell line)
  • Manufactured under an ISO 13485:2016 quality management system with aseptic ISO Class 5 fill & finish
  • Contains phenol red (11 mg/L) for visual pH monitoring; may interfere with certain fluorescence-based assays
  • Custom formulations available on request — pH, glucose, salts, HEPES, and nutrient composition
DCP-MEMH-QPBN1X |Sizes: 500 mL, 1000 mL |Cell Culture Media UNSPSC: 41116155 | Commodity: Molecular biology and cell culture growth media | (UNv260801)
Minimum Essential Medium (MEM), Low Glucose & 25mM HEPES w/o L-Glutamine, Sodium Pyruvate, Sodium Bicarbonate: 1X Liquid
  • Glucose1000 mg/L (1.0 g/L)
  • L-GlutamineNot added
  • Sodium PyruvateNot added
  • HEPES5958 mg/L (25 mM)
  • pH (USP <791>)7.4
  • Osmolality (USP <785>)Contact for specification
  • Endotoxin (USP <85>)< 0.05 EU/mL
  • Filtration0.1 µm ×2 + 0.04 µm ×2
  • Storage2–8°C, protect from light
  • Shelf Life12 months from date of manufacture, unopened
ISO 13485:2016 USP <85> <785> <788> RUO
Why FluxMPS™

Engineered where standard media fails

Conventional 0.22 µm-filtered media carry mycoplasma-sized particulates (0.2–0.3 µm), subvisible debris, and lot-to-lot variability that accumulate inside microchannels — corrupting biosensor readings, triggering inflammation in primary cultures, and shortening device lifetimes. FluxMPS™ is built to address these failure modes at the filtration stage.

filter_alt

Microchannel-safe purity

0.04 µm final filter retains particles to sub-mycoplasma size; USP <788> Method 1 (light obscuration) particulate compliance verified per lot.

target

Total metabolic control

User-defined carbon source (1.0 g/L glucose) and precise nutrient concentrations for metabolic flux experiments and Warburg-related applications.

water_drop

Ultrapure-grade water

Prepared with Type 1 water (18.2 MΩ·cm, ASTM D1193 / ISO 3696) with controlled trace-metal and total organic carbon (TOC) content.

visibility

Low background for imaging

Ultra-low particulate baseline supports confocal microscopy, live-cell biosensors, and TEER measurements. Note: this formulation contains phenol red (11 mg/L), which may contribute background absorbance in some fluorescence-based assays.

science

Rich, stable nutrient profile

Micro-batch precision locks in amino acid and vitamin concentrations for lot-to-lot reproducibility in long-term perfusion studies.

tune

Customization on demand

pH, glucose, salts, HEPES, and full nutrient composition available on request. Contact support@diagnocine.com.

Purity Architecture

Quadruple-stage filtration system

FluxMPS™ Minimum Essential Medium (MEM), Low Glucose & 25mM HEPES w/o L-Glutamine, Sodium Pyruvate, Sodium Bicarbonate: 1X Liquid is processed through a four-stage filtration train reaching a 0.04 µm final cut-off — addressing mycoplasma-sized particulates and subvisible material that 0.22 µm filtration does not retain.

  1. 1

    0.1 µm Prefiltration I

    Removes large particulates, cell debris, and protein aggregates; protects the first 0.04 µm final filter cartridge.

  2. 2

    0.04 µm Final filtration I

    First 0.04 µm pass; retains sub-micron particulates and microaggregates that pass through a 0.22 µm filter.

  3. 3

    0.1 µm Prefiltration II

    Second dedicated prefilter, protecting the second 0.04 µm final filter cartridge.

  4. 4

    0.04 µm Final filtration II — Polish

    Ultimate polishing filter; aseptic fill & finish in a validated ISO Class 5 laminar-flow workstation.

Filtration architecture vs. conventional media

A quadruple-stage train (0.1 µm ×2 + 0.04 µm ×2) reaches a 0.04 µm final cut-off, five times finer than the 0.22 µm membranes used in conventional single-pass filtration. Every lot is verified for USP <788> Method 1 (light obscuration) particulate compliance.

5×
Finer final pore size than conventional 0.22 µm media (0.22 ÷ 0.04)
0.04
µm final filter pore size — sub-mycoplasma polishing
Sterility assurance: Every lot undergoes 14-day USP <71> sterility testing. Mycoplasma risk is controlled via 0.1 µm mycoplasma-retentive filtration (not tested per lot).
Grade: This product is Microfluidics Suitable, filtered to a 0.04 µm final cut-off. It is not an MPS Grade product — that designation is reserved for the 0.01 µm ultra nano-filtered line, which adds 0.02 µm and 0.01 µm stages after the 0.04 µm polish. For applications requiring the 0.01 µm cut-off, contact support@diagnocine.com.
FluxMPS Minimum Essential Medium (MEM), Low Glucose & 25mM HEPES w/o L-Glutamine, Sodium Pyruvate, Sodium Bicarbonate: 1X Liquid (DCP-MEMH-QPBN1X) Quadruple-stage filtration system: 0.1 micron Prefiltration I, 0.04 micron Final filtration I, 0.1 micron Prefiltration II, 0.04 micron Final filtration II - Polish, for organ-on-a-chip and microfluidic applications by Diagnocine
Figure 1. FluxMPS™ Quadruple-stage filtration architecture (0.1 µm ×2 + 0.04 µm ×2).
© Diagnocine® — DCP-MEMH-QPBN1X
Applications

Designed for next-generation cell culture platforms

FluxMPS™ Minimum Essential Medium (MEM), Low Glucose & 25mM HEPES w/o L-Glutamine, Sodium Pyruvate, Sodium Bicarbonate: 1X Liquid is suited to organ-on-a-chip, metabolic research, live-cell imaging, and primary cell models where particulate load and formulation control matter.

Automated Bioreactors & Robotics

Next-Generation System Uptime

An optional 0.01 µm (10 nm) ultra-filtered MPS Grade variant is available for automated bioreactor and robotic perfusion systems requiring the ultimate particulate exclusion.

  • Total Particulate Exclusion: 10 nm filtration for nanoscale valve and sensor protection
  • Valve & Sensor Protection: prevents particulate-induced blockage in precision fluidic systems
  • Extended Perfusion Stability: maintains flow rate consistency across multi-week automated runs

Inquiry Required: Contact support@diagnocine.com to request the 0.01 µm MPS Grade variant.

Microfluidics

Micro Physiological System (MPS) & Chip

Ultra-filtered formulation supports microchannel flow integrity in chip-based culture systems.

OoCToCBoCLoCMPS
Cancer Biology

Warburg Effect & Metabolic Research

Defined carbon source (1.0 g/L glucose) enables metabolic flux analysis with a known baseline.

MCF-7MDA-MB-231HeLaHT-1080
Stem Cell Biology

iPSC-Derived Models

Low-particulate formulation supports sensitive iPSC differentiation protocols.

iPSC-NeuronsiPSC-CMiPSC-Hep
Vascular Biology

Endothelial & Primary Cells

Microchannel-safe purity supports maintenance of endothelial barrier integrity and TEER measurements.

HUVECsBHK-21Primary fibroblasts
Metabolomics

Metabolic Flux Analysis

Defined glucose content (1.0 g/L) supports 13C isotope tracing and NMR-based metabolomics workflows. Not compatible with Agilent Seahorse XF assays, which require bicarbonate-free, phenol red-free medium.

13C tracingNMR metabolomics
Live-Cell Imaging

Microscopy & Optical Sensing

Ultra-low particulate load supports confocal imaging and biosensor integration; note that phenol red in this formulation may contribute background absorbance for some fluorescence-based assays.

ConfocalBiosensorsTEER
Technical Specifications

Lot-release quality parameters

Every production lot of FluxMPS™ Minimum Essential Medium (MEM), Low Glucose & 25mM HEPES w/o L-Glutamine, Sodium Pyruvate, Sodium Bicarbonate: 1X Liquid undergoes the quality-release battery below before shipment.

Physical & Chemical Parameters
Parameter Specification
Formulation Low-glucose MEM base with 25 mM HEPES; contains Phenol Red, HEPES, Calcium, and Magnesium; without L-Glutamine, Sodium Bicarbonate, and Sodium Pyruvate
Appearance Orange-to-red colored, clear solution
pH USP <791> 7.4
Osmolality USP <785> Contact for specification
Glucose 1000 mg/L (1.0 g/L)
L-Glutamine Not added
Sodium Pyruvate Not added
Phenol Red 11 mg/L (present)
Sterility, Purity & Safety Parameters
Parameter Specification
Endotoxin USP <85> BET < 0.05 EU/mL
Sterility USP <71> No growth after 14 days
Mycoplasma 0.1 µm mycoplasma-retentive filtration (not tested per lot)
Particulate ≥10 µm USP <788> M1 Compliant
Particulate ≥25 µm USP <788> M1 Compliant
Water Purity Ultrapure Type 1, 18.2 MΩ·cm (ASTM D1193 / ISO 3696)
Manufacturing std. ISO 13485 ISO 13485:2016
Fill environment ISO Class 5 (Class 100)
Storage, Handling & Logistics
Parameter Specification
Storage temperature 2–8°C, protected from light
Freeze-thaw Not recommended
Shelf life 12 months from date of manufacture, unopened
Shipping condition Cold pack
CO2 requirement HEPES-buffered; reduced CO2 dependence (validate per cell line)
Raw Materials & Regulatory Traceability
Parameter Specification
Raw material grade Cell culture / reagent grade
Traceability Full lot documentation, CoA available
Manufacturing QMS ISO 13485:2016 certified
UNSPSC 41116155 — Molecular biology and cell culture growth media (UNv260801)
Regulatory alignment 21 CFR Part 820 (QMSR) aligned
Production method Micro-batch precision manufacturing
Intended use For Research Use Only (RUO)
Formulation

Full composition (mg/L)

Complete formulation with CAS numbers, reproduced from manufacturer specification. Total: 28 components across 4 category groups. Custom compositions available on request.

Component CAS Number mg/L
INORGANIC SALTS
Calcium chloride dihydrate 10035-04-8 265.000
Magnesium sulfate anhydrous 7487-88-9 97.720
Potassium chloride 7447-40-7 400.000
Sodium chloride 7647-14-5 6800.00
Sodium phosphate dibasic anhydrous 7558-79-4 122.000
Component CAS Number mg/L
AMINO ACIDS
L-Arginine hydrochloride 1119-34-2 126.000
L-Cystine dihydrochloride 30189-89-0 31.300
L-Histidine hydrochloride monohydrate 5934-29-2 42.000
L-Isoleucine 73-32-5 52.000
L-Leucine 61-90-5 52.000
L-Lysine hydrochloride 657-27-2 72.500
L-Methionine 63-68-3 15.000
L-Phenylalanine 63-91-2 32.000
L-Threonine 72-19-5 48.000
L-Tryptophan 73-22-3 10.000
L-Tyrosine disodium salt 69847-45-6 51.900
L-Valine 72-18-4 46.000
Component CAS Number mg/L
VITAMINS
Choline chloride 67-48-1 1.000
D-Ca-Pantothenate 137-08-6 1.000
Folic acid 59-30-3 1.000
Niacinamide 98-92-0 1.000
Pyridoxine hydrochloride 58-56-0 1.000
Riboflavin 83-88-5 0.100
Thiamine hydrochloride 67-03-8 1.000
OTHERS
i-Inositol 87-89-8 2.000
D-Glucose 50-99-7 1000.000
HEPES 7365-45-9 5958.000
Phenol red sodium salt 34487-61-1 11.000
Customization: pH, glucose, salt balance, HEPES, and full nutrient profile available on request. Contact support@diagnocine.com.
Quality Assurance

ISO 13485:2016 manufacturing & compliance

Manufactured under ISO 13485:2016 QMS with final packaging, testing, and customization at Diagnocine Precision in Totowa, New Jersey, USA.

verified

ISO 13485:2016 QMS

Full quality management system certification covering manufacturing, testing, and release for every production lot.

water_drop

Ultrapure Type 1 Water

All media prepared with 18.2 MΩ·cm resistivity water (ASTM D1193 / ISO 3696 Type 1), with controlled trace-metal and total organic carbon (TOC) content.

biotech

ISO Class 5 Fill & Finish

Aseptic filling in validated ISO Class 5 laminar-flow workstations; 21 CFR Part 820 (QMSR) aligned.

assignment

Micro-Batch Precision

Small-batch manufacturing supports lot-to-lot nutrient consistency for reproducible perfusion studies.

Endotoxin — USP <85> BET

LAL assay on every batch. Release specification: < 0.05 EU/mL; assay sensitivity 0.005 EU/mL.

Particulate — USP <788> Method 1

Light obscuration particle count confirms ≥10 µm and ≥25 µm compliance per lot.

Osmolality — USP <785>

Freezing-point osmometry per USP <785>. Result reported on the Certificate of Analysis.

Documentation — CoA & Full Lot Records

Certificate of Analysis with full QC panel, traceability, and release signatures for every lot.

Batch-level quality control. Endotoxin is controlled per manufacturing batch rather than per unit. Every batch is tested before release and must meet the release specification:
  • Endotoxin — LAL assay, USP <85> Bacterial Endotoxins Test; assay sensitivity 0.005 EU/mL; release specification < 0.05 EU/mL
  • pH, osmolality, conductivity, appearance and clarity
  • Sterility
A Certificate of Analysis is available on request via support@diagnocine.com with your lot number.
Product Comparison

How DCP-MEMH-QPBN1X (FluxMPS™) compares

Side-by-side comparison against conventional 0.22 µm-filtered alternatives of the same base formulation.

Parameter DCP-MEMH-QPBN1X (FluxMPS™) Conventional MEM (0.22 µm) Standard MEM alternative
Grade Microfluidics Suitable Standard grade Standard grade
Base Formulation Low-glucose MEM, 25mM HEPES, w/o L-Glutamine, Sodium Pyruvate, Sodium Bicarbonate MEM Standard MEM Equivalent
Final filtration pore size 0.04 µm 0.22 µm 0.22 µm
Number of filtration stages 4 stages 1 stage 1–2 stages
Mycoplasma-retentive filtration check_circle cancel cancel
Endotoxin (release specification) < 0.05 EU/mL Corning classical liquid media — < 0.25 EU/mL
Sigma-Aldrich DMEM complete medium — ≤ 2 EU/mL
Gibco classical DMEM — Not specified (recorded per lot)
USP particulate compliance check_circle USP <788> M1 cancel cancel
Water quality Ultrapure Type 1 (18.2 MΩ·cm) Purified water Purified water
Manufacturing QMS ISO 13485:2016 Variable Variable
Microfluidic channel compatibility check_circle Validated cancel Risk of clogging cancel Risk of clogging
Custom formulation check_circle On request cancel Limited

Comparison figures from published supplier specifications, accessed 2026-09-02. Suppliers that publish no numeric endotoxin specification are shown as "Not specified".

FAQ

Frequently asked questions

Common questions about FluxMPS™ Minimum Essential Medium (MEM), Low Glucose & 25mM HEPES w/o L-Glutamine, Sodium Pyruvate, Sodium Bicarbonate: 1X Liquid.

Yes. DCP-MEMH-QPBN1X uses a quadruple-stage filtration train (0.1 µm ×2 + 0.04 µm ×2), delivering a 0.04 µm final cut-off that supports microchannel-safe perfusion in OoC and MPS devices.
Standard 0.22 µm filtration does not retain mycoplasma-sized particulates (0.2–0.3 µm). FluxMPS™ uses four sequential stages reaching a 0.04 µm final cut-off — five times finer than 0.22 µm — verified per lot under USP <788> Method 1.
This is a base formulation designed for custom supplementation. L-glutamine (or a stable dipeptide alternative) should be added to a final concentration appropriate for your cell type immediately before use. Sodium pyruvate can be added if required by your protocol. This formulation is HEPES-buffered and bicarbonate-free, so CO2 supplementation is not required for pH control — see the next question.
This formulation is HEPES-buffered and bicarbonate-free, reducing CO2 dependence. Validate incubation conditions per cell line.
Yes. This medium can be supplemented with FBS, growth factors, antibiotics, or other additives per standard practice. For serum or protein-containing supplements, use a 0.2 µm low-protein-binding PES or PVDF filter (never 0.04 µm, which retains serum proteins). Add supplements immediately before use.
Every production batch is tested by LAL assay per USP <85> BET before release. Release specification: < 0.05 EU/mL; assay sensitivity 0.005 EU/mL. Batch-specific results are available in the Certificate of Analysis.
Yes. A lot-specific CoA is available for every shipment and includes: appearance, pH (USP <791>), osmolality (USP <785>), endotoxin (USP <85> BET), sterility (USP <71>), particulate matter (USP <788>), raw material traceability, manufacturing date, and authorized release signatures. Request via support@diagnocine.com.
Scientific References

Supporting literature

Peer-reviewed publications supporting ultra-filtered media and microfluidic cell culture applications.

  1. Huh D et al. (2010). Reconstituting organ-level lung functions on a chip. Science, 328(5986), 1662–1668. doi:10.1126/science.1188302
  2. Bhatia SN & Ingber DE (2014). Microfluidic organs-on-chips. Nature Biotechnology, 32(8), 760–772. doi:10.1038/nbt.2989
  3. Eagle H (1959). Amino acid metabolism in mammalian cell cultures. Science, 130(3373), 432–437. doi:10.1126/science.130.3373.432
  4. Bhattacharya S et al. (2018). Challenges in maintaining cell viability during microfluidic experiments. Electrophoresis, 39(7), 997–1006. doi:10.1002/elps.201700375
  5. Zhang YS et al. (2017). Multisensor-integrated organs-on-chips platform for automated in situ monitoring. PNAS, 114(12), E2293–E2302. doi:10.1073/pnas.1612906114
  6. Vernetti L et al. (2017). Functional coupling of human microphysiology systems. Scientific Reports, 7, 42296. doi:10.1038/srep42296
  7. Esch EW et al. (2015). Organs-on-chips at the frontiers of drug discovery. Nature Reviews Drug Discovery, 14(4), 248–260. doi:10.1038/nrd4539
  8. Zheng F et al. (2021). Organ-on-a-chip systems: microengineering to biomimic living systems. Small, 17(7), 2004175. doi:10.1002/smll.202004175

Satisfaction