FluxMPS™ Leibovitz's L-15 Medium w/o L-Glutamine, Sodium Pyruvate: 2X Liquid

Product#: DCP-LL15-QP2X
$77.00
DCP-LL15-QP2X
Availability:
Ships in 1-2 Weeks

verified ISO 13485 Certified Manufacturing

FluxMPS™ Leibovitz's L-15

FluxMPS™ DCP-LL15-QP2X is an MPS-grade, ultra-filtered Leibovitz's L-15 2X formulation engineered for Primary cells and related cell models on organ-on-a-chip (OoC) and microphysiological system (MPS) platforms. Processed through a Quadruple-stage filtration system (0.1 µm ×2 + 0.04 µm ×2), it delivers approximately 5× lower particulate counts than conventional 0.22 µm–filtered media. CO₂-free by design — uses D-galactose and high amino acid buffering for atmospheric pH maintenance. Formulation: [+] 1.8 g/L D-Galactose | [-] L-Glutamine, [-] Sodium Pyruvate.

  • CO₂-free by design: D-galactose energy source + high amino acid buffering — no gas supplementation required
  • 0.04 µm final nano-filtration — sub-mycoplasma purity; < 0.05 EU/mL endotoxin
  • Quadruple-stage filtration: 0.1 µm pre-I → 0.04 µm pre-II → 0.1 µm sterile-I → 0.04 µm final polish
  • Ultrapure Type 1 water (18.2 MΩ·cm), ISO 13485:2016 QMS, ISO Class 5 fill
CAT. NO.
DCP-LL15-QP2X | UNSPSC 41122100 Cell Culture Media
Leibovitz's L-15 — 1X Liquid
  • Media familyLeibovitz's L-15 2X
  • Carbon (Galactose)1800 mg/L (1.8 g/L, D-Galactose)
  • Formulation[+] 1.8 g/L D-Galactose | [-] L-Glutamine, [-] Sodium Pyruvate
  • AppearanceOrange-Red colored, clear solution
  • pH (USP <791>)7.4
  • Osmolality (USP <785>)620.00–680.00 mOsm/kg H₂O
  • Endotoxin (USP <85>)< 0.05 EU/mL
  • Filtration0.1 µm ×2 + 0.04 µm ×2
  • Shelf Life12 months / 2–8°C
ISO 13485:2016 USP <85> <785> <788> RUO
Why FluxMPS™

Engineered where standard media fails

Conventional 0.22 µm–filtered Leibovitz's passes mycoplasma, subvisible particulates, and endotoxin fragments that interfere with CO₂-free pH maintenance and live imaging clarity. FluxMPS™ eliminates these failure modes.

filter_alt

Microchannel-safe purity

0.04 µm final filtration; USP <788> particulate compliance. Particle-free L-15 for clear live imaging and CO2-free chip loading.

science

CO₂-free by design formulation

Leibovitz's L-15 uses D-galactose (not glucose) as the primary carbon source and high amino acid concentrations for CO₂-free pH buffering. This is a 2X concentrated formulation.

water_drop

Ultrapure-grade water

18.2 MΩ·cm — eliminates ionic contaminants that interfere with L-15 amino acid buffering capacity.

shield

Below TLR4 endotoxin threshold

< 0.05 EU/mL — prevents LPS-driven inflammatory activation in primary cells.

bolt

CO₂-free design

D-galactose + high amino acid buffering maintains pH 7.2–7.5 in atmospheric conditions — no CO₂ required.

tune

Customization on demand

pH, nutrient concentrations, HEPES, and component modifications available. Contact support@diagnocine.com.

Purity Architecture

Quadruple-stage filtration system

Four serial filtration stages reaching a final 0.04 µm polish under ISO Class 5 aseptic conditions.

  1. 1

    0.1 µm Pre-filtration I — Large Particulate Removal

    Removes large aggregates; protects downstream 0.04 µm membranes.

  2. 2

    0.04 µm Pre-filtration II — Mycoplasma Barrier

    Retains mycoplasma (0.1–0.3 µm) — absent from standard 0.22 µm filtration.

  3. 3

    0.1 µm Sterile-filtration I — Second-pass Redundancy

    Second-pass sterility redundancy; no breakthrough from Stage 1.

  4. 4

    0.04 µm Sterile-filtration II — Final Polish

    Ultimate sub-mycoplasma polish; ISO Class 5 aseptic fill & finish.

Performance vs. conventional media

FluxMPS™ DCP-LL15-QP2X delivers approximately 5× lower particulate counts than standard 0.22 µm filtered Leibovitz's, with confirmed mycoplasma barrier at every production stage.

Cleaner than 0.22 µm media by particulate count
0.04
µm Final pore size — sub-mycoplasma polishing
Sterility & Mycoplasma: No growth after 14-day incubation (USP <71>); mycoplasma-negative by 0.04 µm barrier every lot.
FluxMPS-Quadruple-stage-filtration-system-Cell-Culture-Media-Diagnocine-V2.jpg
Figure 1. FluxMPS™ Quadruple-stage filtration system (0.1 µm ×2 + 0.04 µm ×2).
© Diagnocine® — DCP-LL15-QP2X
Applications

CO₂-free live imaging and primary cell applications

FluxMPS™ DCP-LL15-QP2X — Leibovitz's L-15 2X — delivers 0.04 µm filtered purity for Primary cells and related OoC applications.

Automated Bioreactors & Robotics

Next-Generation System Uptime

Optional 0.01 µm (10 nm) ultra-filtered variant available on request.

  • Total Particulate Exclusion: 10 nm filtration removes nanoparticulate aggregates
  • Valve & Sensor Protection: Eliminates micro-fouling in automated perfusion systems
  • Extended Perfusion Stability: Consistent nutrient delivery over long-duration culture

Inquiry Required: Contact support@diagnocine.com for the 0.01 µm variant.

Live-Cell Imaging

Open-Stage & CO₂-Free Microscopy

L-15 + galactose maintains pH without CO₂ — the standard base for prolonged live-cell confocal, TIRF, light-sheet, and spinning disk imaging on open-stage microscopes.

ConfocalTIRFLight-sheetOpen-stage
Cell Biology

Primary Cell Dissociation & Transport

CO₂-free L-15 is the standard dissociation and transport buffer for primary cells, tissue pieces, and organoids outside the incubator.

Primary cellsOrganoidsTissue dissociation
Microfluidics

OoC Loading & Priming

CO₂-independent L-15 enables chip loading, priming, and cell seeding outside incubators without pH drift during the critical chip assembly steps.

OoC loadingChip primingCell seeding
In Vivo Studies

In Vivo Imaging & Intravital Microscopy

L-15 is the standard superfusion medium for intravital microscopy, maintaining pH in open tissue preparations without CO₂ during surgical and imaging procedures.

IntravitalSuperfusionIn vivo
Metabolomics

CO₂-Free Metabolic Studies

Galactose-based energy source enables metabolic studies without CO₂ interference. Galactose forces OXPHOS in metabolically flexible cells.

OXPHOSGalactose forcingMetabolomics
Neuroscience

Acute Brain Slice & Neuron Imaging

CO₂-free L-15 maintains neuronal viability in acute brain slice preparations and dissociated neuron imaging without requiring carbogen (95% O₂/5% CO₂) gassing.

Brain slicesPrimary neuronsNeuronal imaging
Technical Specifications

Analytical release specifications

Every lot released against the full specification matrix. CoA: support@diagnocine.com.

Physical & Chemical Parameters
Parameter Specification
Formulation [+] 1.8 g/L D-Galactose | [-] L-Glutamine, [-] Sodium Pyruvate
Appearance Orange-Red colored, clear solution
Carbon source D-Galactose: 1800 mg/L (1.8 g/L, D-Galactose)
pH USP <791> 7.4
Osmolality USP <785> 620.00–680.00 mOsm/kg H₂O
Total ingredients 33
Sterility, Purity & Safety
Parameter Specification
Endotoxin USP <85> BET < 0.05 EU/mL
Sterility USP <71> No growth / 14 days
Mycoplasma Negative (0.04 µm barrier)
Particulate ≥10 µm USP <788> NMT 25/mL
Particulate ≥25 µm USP <788> NMT 3/mL
Water purity Type 1, 18.2 MΩ·cm
Manufacturing std. ISO 13485:2016
Fill environment ISO Class 5 (Class 100)
Storage, Handling & Logistics
Parameter Specification
Storage temperature 2–8°C, away from light
Freeze-thaw Do not freeze
Shelf life 12 months from manufacture
Shipping condition cold pack
CO₂ requirement CO₂-independent by design — Leibovitz's L-15 uses galactose and high amino acid buffering for CO₂-free pH maintenance. No gas supplementation required.
Raw Materials & Regulatory
Parameter Specification
Raw material grade Reagent / cell culture grade
Traceability Full lot traceability per ISO 13485
Manufacturing QMS ISO ISO 13485:2016 certified
Regulatory alignment 21 CFR Part 820 (cGMP) aligned
Production method Micro-batch, per-lot QC release
Intended use Research Use Only (RUO)
Formulation

Full composition (mg/L)

Leibovitz's L-15 2X: 33 ingredients verified per lot with CAS numbers for full raw-material traceability. Leibovitz's L-15 uses D-galactose (not glucose) as the primary carbon source and high amino acid concentrations for CO₂-free pH buffering. This is a 2X concentrated formulation.

Component CAS Number mg/L
INORGANIC SALTS
Calcium chloride dihydrate 10035-04-8 370.000
Magnesium chloride hexahydrate 7791-18-6 400.000
Magnesium sulphate anhydrous 7487-88-9 195.440
Potassium chloride 7447-40-7 800.000
Potassium phosphate monobasic 7778-77-0 120.000
Sodium chloride 7647-14-5 16000.000
Sodium dihydrogen phosphate anhydrous 7558-80-7 380.240
Component CAS Number mg/L
AMINO ACIDS
L-Alanine 56-41-7 450.000
Glycine 56-40-6 400.000
L-Arginine (free base) 74-79-3 1000.000
L-Asparagine 70-47-3 500.000
L-Cysteine (free base) 52-90-4 240.000
L-Histidine (free base) 71-00-1 500.000
L-Isoleucine 73-32-5 500.000
L-Leucine 61-90-5 250.000
L-Lysine hydrochloride 657-27-2 188.000
L-Methionine 63-68-3 150.000
L-Phenylalanine 63-91-2 250.000
L-Serine 56-45-1 400.000
L-Threonine 72-19-5 600.000
L-Tryptophan 73-22-3 40.000
L-Tyrosine disodium salt 69847-45-6 552.320
L-Valine 72-18-4 200.000
Component CAS Number mg/L
VITAMINS
Choline chloride 67-48-1 2.000
D-Ca-Pantothenate 137-08-6 2.000
Folic acid 59-30-3 2.000
Nicotinamide 98-92-0 2.000
Pyridoxine hydrochloride 58-56-0 2.000
Riboflavin-5-phosphate sodium salt 130-40-5 0.200
Thiamine hydrochloride 67-03-8 2.000
i-Inositol 87-89-8 4.000
OTHERS
D-Galactose 59-23-4 1800.000
Phenol red sodium salt 34487-61-1 22.000
Custom formulation: Contact support@diagnocine.com for DCP-LL15-QP2X modifications.
Quality Assurance

Manufacturing & compliance

Every FluxMPS™ product manufactured and released under a rigorous multi-layer quality system.

verified

ISO 13485:2016 Quality Management

Manufactured under ISO 13485:2016–certified and CE-approved facilities. Final QA at DiagnoCine R&D Center, Totowa, NJ, USA.

water_drop

Ultrapure Type 1 Water

18.2 MΩ·cm — eliminates ionic contaminants.

biotech

ISO Class 5 Fill & Finish

Aseptic fill in validated ISO Class 5 (Class 100) laminar-flow workstations.

assignment

Micro-Batch Precision

Small-batch, per-lot tested — no blending, Certificate of Analysis for every lot.

Endotoxin — USP <85> BET

LAL assay < 0.05 EU/mL per lot.

Particulate — USP <788> Method 2

≤25/mL (≥10 µm), ≤3/mL (≥25 µm).

Osmolality — USP <785>

Target: 620.00–680.00 mOsm/kg H₂O.

Documentation & CoA

Full CoA with raw-material traceability available on request.

Certificate of Analysis: Request for any DCP-LL15-QP2X lot at support@diagnocine.com.
Product Comparison

How DCP-LL15-QP2X compares

FluxMPS™ DCP-LL15-QP2X vs. conventional 0.22 µm–filtered Leibovitz's formulations.

Parameter DCP-LL15-QP2X (FluxMPS™) Conventional Leibovitz's L-1
(0.22 µm filtered)
Standard DMEM/RPMI
(0.22 µm filtered)
L-15 2X without L-Glutamine and Sodium Pyruvate — complete nitrogen and energy substrate control for CO₂-free culture check_circle Yes cancel No cancel No
Final filtration pore size 0.04 µm 0.22 µm 0.22 µm
Number of filtration stages 4 (Quadruple) 1 1
Mycoplasma barrier check_circle Yes (0.04 µm) cancel No cancel No
CO₂-free design check_circle Yes (galactose) check_circle Yes cancel No
Endotoxin specification < 0.05 EU/mL NMT 1 EU/mL NMT 1 EU/mL
USP <788> particulate tested check_circle Yes cancel No cancel No
Water quality Type 1, 18.2 MΩ·cm Purified water Purified water
Manufacturing QMS ISO 13485:2016 ISO 9001 or none ISO 9001 or none
Microfluidic channel compatible check_circle MPS-grade cancel Risk of clogging cancel Risk of clogging
FAQ

Frequently asked questions

Common questions about FluxMPS™ DCP-LL15-QP2X — Leibovitz's L-15 2X.

DCP-LL15-QP2X is processed through a Quadruple-stage filtration system reaching 0.04 µm final pore size. Leibovitz L-15 CO₂-free design makes it ideal for chip loading, priming, open-stage imaging, and atmospheric OoC platforms where CO₂ control is impractical.
FluxMPS™ uses four sequential filters — 0.1 µm pre-filtration I, 0.04 µm pre-filtration II (mycoplasma barrier), 0.1 µm sterile-filtration I, and 0.04 µm final polish — resulting in approximately 5× fewer particles and confirmed mycoplasma retention at every production stage.
Both nitrogen source (glutamine) and secondary carbon (pyruvate) are removed for independent fresh addition. This enables precise control of both energy substrate and nitrogen in CO₂-free primary cell dissociation, transport, and metabolic studies where individual contributions of glutamine and pyruvate need to be isolated.
CO₂-independent by design — Leibovitz's L-15 uses galactose and high amino acid buffering for CO₂-free pH maintenance. No gas supplementation required..
Yes. Add FBS (5–10%), serum-free supplements, growth factors, or antibiotics as required. Contact support@diagnocine.com for custom co-formulation.
FluxMPS™ DCP-LL15-QP2X is produced to meet < 0.05 EU/mL by LAL assay (USP <85>). For primary cells, endotoxin activates TLR4 altering cell phenotype and differentiation outcomes.
Yes. Full CoA per lot covers: appearance, pH (USP <791>), osmolality (USP <785>), sterility (USP <71>), endotoxin (USP <85>), mycoplasma, particulate count (USP <788> Method 2), and raw-material traceability. Request at support@diagnocine.com.
Scientific References

Supporting literature

Key publications supporting Leibovitz's L-15 2X in CO₂-free live-cell imaging, primary cell culture, and OoC applications.

  1. Leibovitz A. The growth and maintenance of tissue-cell cultures in free gas exchange with the atmosphere. Am J Hyg. 1963;78:173–180. doi:10.1083/jcb.1.3.273
  2. Huh D, et al. Reconstituting organ-level lung functions on a chip. Science. 2010;328:1662–1668. doi:10.1126/science.1188302
  3. Bhatia SN, Ingber DE. Microfluidic organs-on-chips. Nat Biotechnol. 2014;32:760–772. doi:10.1038/nbt.2989
  4. Novak R, et al. Robotic fluidic coupling and interrogation of multiple vascularized organ chips. Nat Biomed Eng. 2020;4:407–420. doi:10.1038/s41551-019-0497-x
  5. Jang KJ, et al. Human kidney proximal tubule-on-a-chip. Integr Biol. 2013;5:1119–1129. doi:10.1039/c3ib40049b
  6. Schimek K, et al. Integrating biological vasculature into a multi-organ-chip microsystem. Lab Chip. 2013;13:3588–3598. doi:10.1039/c3lc50217a
  7. Luni C, et al. High-efficiency cellular reprogramming with microfluidics. Nat Methods. 2016;13:446–452. doi:10.1038/nmeth.3832
  8. Sung JH, et al. Microfabricated mammalian organ systems. Lab Chip. 2013;13:1201–1212. doi:10.1039/c3lc41017j

Satisfaction
Quality Rating
Value Rating
Style Rating