FluxMPS™ Dulbecco's Modified Eagle Medium (DMEM), 25mM HEPES w/o Glucose: 1X Liquid

Product#: DCP-DMEMH-G1X
$44.00
DCP-DMEMH-G1X
Availability:
Ships in 1-2 Weeks

warning For Research Use Only (RUO). Not intended for clinical, diagnostic, or therapeutic use in humans.
verified ISO 13485 Certified Manufacturing

FluxMPS™ Dulbecco's Modified Eagle Medium (DMEM), 25mM HEPES w/o Glucose: 1X Liquid

Contains L-Glutamine Contains Sodium Bicarbonate Contains Phenol Red Contains 25mM HEPES Contains Calcium Contains Magnesium Contains Sodium Pyruvate Without Glucose

Microfluidics Suitable, quadruple-stage ultra-filtered (0.1 µm ×2 + 0.04 µm ×2) 1X liquid cell culture medium engineered for microfluidic channels, organ-on-a-chip (OoC), and microphysiological systems (MPS). Manufactured under ISO 13485:2016 in an ISO Class 5 fill environment using Ultrapure Type 1 water (18.2 MΩ·cm). Final 0.04 µm polish reduces sub-visible particulate load beyond conventional 0.22 µm filtration.

  • Quadruple-stage filtration train (0.1 µm → 0.04 µm → 0.1 µm → 0.04 µm) reaching a 0.04 µm final cut-off, engineered for microfluidic channels and organ-on-a-chip (OoC) systems
  • HEPES-supplemented (25 mM) DMEM base retaining standard sodium bicarbonate (3700 mg/L) buffering — supports incubator and bench-top handling
  • Glucose removed for precise, user-defined carbon-source control in Warburg-effect and metabolic flux studies; L-glutamine (584 mg/L) and sodium pyruvate (110 mg/L) retained
  • Endotoxin release specification: < 0.05 EU/mL (LAL, USP <85>), tested per manufacturing batch
  • Manufactured under an ISO 13485:2016 quality management system with aseptic ISO Class 5 (Class 100) fill and finish
  • Ultrapure Type 1 water (18.2 MΩ·cm) feedstock supports a low trace-metal, low-organic-carbon formulation
  • 4× BME amino acid & vitamin concentrations for extended microphysiological system (MPS) perfusion
  • Custom pH, glucose reintroduction, HEPES, salts & nutrients available on request — support@diagnocine.com
DCP-DMEMH-G1X · Cell Culture Media UNSPSC: 41116155 | Commodity: Molecular biology and cell culture growth media | (UNv260801)
Dulbecco's Modified Eagle Medium (DMEM), 25mM HEPES w/o Glucose: 1X Liquid
  • GlucoseNone / Not added
  • L-Glutamine584 mg/L ([+])
  • Sodium Pyruvate110 mg/L ([+])
  • pH (USP <791>)7.4
  • Osmolality (USP <785>)310 - 350 mOsm/kg
  • Endotoxin (USP <85>)< 0.05 EU/mL
  • Filtration0.1µm ×2 + 0.04µm ×2
  • Storage2-8°C, protect from light
  • Shelf Life12 months from date of manufacture, unopened
  • ShippingCold pack (2–8°C)
ISO 13485:2016 USP <85> <785> <788> RUO
Available pack sizes: 500 mL, 1000 mL.
Why FluxMPS™

Engineered where standard media fails

Conventional 0.22 µm filtered media allows mycoplasma (typical diameter 0.2–0.3 µm), sub-visible particulates, and microaggregates to pass freely — clogging microchannels, corrupting biosensors, and invalidating metabolic assays. FluxMPS™ closes that gap.

filter_alt

Microchannel-safe purity

0.04 µm final filter and USP <788> Method 1 (Light Obscuration Particle Count Test) particulate control support unobstructed flow in narrow microfluidic channels.

target

Total metabolic control

Precisely defined carbon sources enable Warburg-effect studies, glycolysis inhibition, and ¹³C metabolic tracing.

water_drop

Ultrapure-grade water

Prepared with Ultrapure Type 1 water (18.2 MΩ·cm) for trace-metal and organic-carbon (TOC) control.

visibility

Low background for imaging

Ultra-low particulate baseline supports confocal live-cell imaging, fluorescent biosensors, and automated high-content analysis on chip.

science

Rich, stable nutrient profile

4× BME amino acid and vitamin concentrations with micro-batch precision — tight lot-to-lot consistency for long-duration MPS perfusion.

tune

Customization on demand

pH, glucose, HEPES, salts, and nutrients adjusted on request. Contact support@diagnocine.com.

Purity Architecture

Quadruple-stage filtration system

A validated four-stage sequential filtration train reaches a final pore size of 0.04 µm — two dedicated prefilter + final-filter pairs run in series for full redundancy.

  1. 1

    0.1 µm Prefiltration I

    Removes large particulates, cell debris, protein aggregates, bacteria and mycoplasma (typical diameter 0.2–0.3 µm). Protects the first 0.04 µm final filter.

  2. 2

    0.04 µm Final filtration I

    Retains fine particulates and sub-micron microaggregates not captured by standard 0.22 µm filtration.

  3. 3

    0.1 µm Prefiltration II

    Second dedicated prefilter, protecting the second 0.04 µm final filter cartridge.

  4. 4

    0.04 µm Final filtration II — Polish

    Ultimate polishing filter; aseptic fill in a validated ISO Class 5 (Class 100) laminar-flow workstation.

Filtration architecture

Two dedicated prefilter + final-filter pairs run in series, each 0.04 µm final filter protected by its own 0.1 µm prefilter, for redundant particulate and bioburden control down to a 0.04 µm cut-off.

4
Sequential filtration passes
0.04
µm final filter — sub-mycoplasma polishing
Sterility & Mycoplasma: 14-day USP <71> sterility tested per lot. Mycoplasma risk is controlled by 0.1 µm mycoplasma-retentive filtration (not tested per lot); mycoplasma typically measures 0.2–0.3 µm in diameter.
Grade: This product is Microfluidics Suitable, filtered to a 0.04 µm final cut-off. It is not an MPS Grade product — that designation is reserved for the 0.01 µm ultra nano-filtered line, which adds 0.02 µm and 0.01 µm stages after the 0.04 µm polish. For applications requiring the 0.01 µm cut-off, contact support@diagnocine.com.
FluxMPS™ Dulbecco's Modified Eagle Medium (DMEM), 25mM HEPES w/o Glucose: 1X Liquid (DCP-DMEMH-G1X) ? Quadruple-stage filtration system (0.1 μm x2 + 0.04 μm x2) for organ-on-a-chip and microfluidic cell culture | Diagnocine
Figure 1. FluxMPS™ Quadruple-stage filtration: 0.1µm Prefiltration I → 0.04µm Final filtration I → 0.1µm Prefiltration II → 0.04µm Final filtration II (Polish) → ISO Class 5 aseptic fill.
© Diagnocine® — DCP-DMEMH-G1X
Formulation

Full Composition (mg/L)

Every ingredient below is present in this 1X liquid formulation at the exact concentration listed. Total: 33 components across 4 categories. All values are per-lot verified and reported on the Certificate of Analysis (CoA).

INORGANIC SALTS

Component CAS Number mg/L
Calcium chloride dihydrate 10035-04-8 265.000
Ferric nitrate nonahydrate 7782-61-8 0.100
Magnesium sulfate anhydrous 7487-88-9 97.720
Potassium chloride 7447-40-7 400.000
Sodium bicarbonate 144-55-8 3700.000
Sodium chloride 7647-14-5 6400.000
Sodium dihydrogen phosphate anhydrous 7558-80-7 109.000

AMINO ACIDS

Component CAS Number mg/L
Glycine 56-40-6 30.000
L-Arginine hydrochloride 1119-34-2 84.000
L-Cystine dihydrochloride 30925-07-6 62.570
L-Glutamine 56-85-9 584.000
L-Histidine hydrochloride monohydrate 5934-29-2 42.000
L-Isoleucine 73-32-5 105.000
L-Leucine 61-90-5 105.000
L-Lysine hydrochloride 657-27-2 146.000
L-Methionine 63-68-3 30.000
L-Phenylalanine 63-91-2 66.000
L-Serine 56-45-1 42.000
L-Threonine 72-19-5 95.000
L-Tryptophan 73-22-3 16.000
L-Tyrosine Disodium Salt dihydrate 69847-45-6 103.790
L-Valine 72-18-4 94.000
Component CAS Number mg/L
VITAMINS
Choline chloride 67-48-1 4.000
D-Ca-Pantothenate 137-08-6 4.000
Folic acid 59-30-3 4.000
Nicotinamide 98-92-0 4.000
Pyridoxal hydrochloride 65-22-5 4.000
Riboflavin 83-88-5 0.400
Thiamine hydrochloride 67-03-8 4.000
i-Inositol 87-89-8 7.200
OTHERS
Phenol red sodium salt 34487-61-1 15.900
Sodium pyruvate 113-24-6 110.000
HEPES 7365-45-9 5958.000
Custom formulations: pH, glucose, HEPES, salts, and individual nutrient levels adjustable on request. Contact support@diagnocine.com.
Technical Specifications

Full technical specification

Every lot of FluxMPS™ Dulbecco's Modified Eagle Medium (DMEM), 25mM HEPES w/o Glucose: 1X Liquid is released against comprehensive multi-parameter QC specifications.

Physical & Chemical Parameters
Parameter Specification
Formulation [+] L-Glutamine, Sodium Bicarbonate, Phenol Red, 25mM HEPES, Calcium, Magnesium, Sodium Pyruvate / [-] Glucose
Appearance Clear solution
pH USP <791> 7.4
Osmolality USP <785> 310 - 350 mOsm/kg H2O
Glucose None / Not added
L-Glutamine 584 mg/L ([+])
Sodium Pyruvate 110 mg/L ([+])
Phenol Red 15.9 mg/L ([+])
Sterility, Purity & Safety Parameters
Parameter Specification
Endotoxin USP <85> < 0.05 EU/mL (batch release; see §Quality Assurance)
Sterility USP <71> No growth after 14 days
Mycoplasma 0.1 µm mycoplasma-retentive filtration (not tested per lot)
Particulate control USP <788> Method 1 Light Obscuration Particle Count Test applied per lot
Water purity Ultrapure Type 1, 18.2 MΩ·cm
Manufacturing ISO 13485:2016 ISO
Fill environment ISO Class 5 (Class 100)
Storage, Handling & Logistics
Parameter Specification
Storage temperature 2-8°C, protect from light
Freeze–thaw Do not freeze
Shelf life 12 months from date of manufacture, unopened
Shipping condition Cold pack (2–8°C)
CO2 requirement ~10% CO2 recommended (44 mM NaHCO3 formulated for pH 7.4 at ~10% CO2); 25 mM HEPES provides supplemental buffering
Raw Materials & Regulatory Traceability
Parameter Specification
Raw material grade Pharmaceutical/research grade CoA
Manufacturing QMS ISO 13485:2016 ISO
UNSPSC 41116155 — Molecular biology and cell culture growth media (UNv260801)
Regulatory alignment 21 CFR Part 820 (QMSR) aligned
Production method Micro-batch; Totowa, NJ, USA
Intended use RUO only
Applications

Optimized for next-generation cell biology platforms

FluxMPS™ Dulbecco's Modified Eagle Medium (DMEM), 25mM HEPES w/o Glucose: 1X Liquid is validated for applications where microchannel cleanliness, signal fidelity, and metabolic precision are critical.

Automated Bioreactors & Robotics

Next-Generation System Uptime

For fully automated bioreactor and robotic liquid-handling platforms, an optional 0.01 µm (10 nm) MPS Grade ultra-filtered variant of this formulation is available — see the Grade note in the Purity Architecture section above.

  • Total Particulate Exclusion — ultra-fine filtration for sensitive valve and sensor networks
  • Valve & Sensor Protection — minimizes fouling in automated microfluidic hardware
  • Extended Perfusion Stability — supports long-duration unattended runs

Inquiry Required: the 0.01 µm MPS Grade variant is available on request — contact support@diagnocine.com.

Microfluidics

Micro Physiological System (MPS) & Chip

Ultra-low particulate, filtration-controlled media for perfusion in organ chips, tissue chips (ToC), and body-on-a-chip (BoC) devices.

OoCToCBoCMPS
Cancer Biology

Warburg Effect & Metabolic Research

Glucose-free formulation for Warburg-effect studies, aerobic glycolysis, and cancer metabolomics with user-defined carbon source.

MCF-7MDA-MB-231HeLaA549
Stem Cell Biology

iPSC-Derived Models

Ultra-clean, low-endotoxin baseline minimizes non-specific signals in iPSC differentiation and functional organoid readouts.

iPSC-NeuronsiPSC-CMiPSC-Hep
Vascular Biology

Endothelial & Primary Cells

Particle-controlled perfusion media for TEER measurement, endothelial monolayer integrity, and primary cell culture.

HUVECsHAECsPrimary hepatocytes
Metabolomics

Metabolic Flux Analysis

Chemically defined, glucose-free formulation for ¹³C metabolic tracing and NMR metabolomics. Not compatible with Agilent Seahorse XF assays, which require bicarbonate-free, phenol red-free medium.

¹³C tracingNMR
Live-Cell Imaging

Microscopy & Optical Sensing

Low particulate baseline supports confocal microscopy, fluorescent biosensors, and automated imaging on chip.

ConfocalBiosensorsTEER
Quality Assurance

Manufacturing & compliance

Every batch subjected to multi-parameter lot-release testing before distribution.

verified

ISO 13485:2016 QMS

Manufactured by ISO 13485-certified suppliers. Final packaging, QA and testing at DiagnoCine R&D Center; customization at DiagnoCine Precision, Totowa, NJ, USA.

water_drop

Ultrapure Type 1 Water

18.2 MΩ·cm feedstock with trace-metal and organic-carbon (TOC) control, supporting low-background performance in biosensor and TEER systems.

biotech

ISO Class 5 Fill & Finish

Validated ISO Class 5 laminar-flow workstation with real-time particle monitoring. Preserves all filtration gains in the final container.

assignment

Micro-Batch Precision

Small-batch production with tight osmolality and pH control, critical for reproducible long-duration MPS experiments.

Endotoxin — USP <85> BET

LAL assay; assay sensitivity 0.005 EU/mL. Release specification: < 0.05 EU/mL, tested per batch.

Particulate — USP <788> Method 1

Light Obscuration Particle Count Test applied per lot following quadruple-stage 0.04 µm filtration.

Osmolality — USP <785>

Freezing-point depression osmometry. Release range: 310 - 350 mOsm/kg H2O.

Certificate of Analysis (CoA)

Full CoA per lot. Request at support@diagnocine.com with lot number.

Batch-level quality control. Endotoxin is controlled per manufacturing batch rather than per unit. Every batch is tested before release and must meet the release specification:
  • Endotoxin — LAL assay, USP <85> Bacterial Endotoxins Test; assay sensitivity 0.005 EU/mL; release specification < 0.05 EU/mL
  • pH, osmolality, conductivity, appearance and clarity
  • Sterility
A Certificate of Analysis is available on request. Email support@diagnocine.com.
Product Comparison

How DCP-DMEMH-G1X compares

Critical advantages in filtration, mycoplasma control, water quality, and QC depth versus conventional media for MPS and microfluidic applications.

Parameter DCP-DMEMH-G1X (FluxMPS™) Standard DMEM (0.22 µm) Competitor DMEM (0.22 µm)
Grade Microfluidics Suitable Not applicable Not applicable
Formulation definition [+] L-Glutamine, Sodium Bicarbonate, Phenol Red, 25mM HEPES, Calcium, Magnesium, Sodium Pyruvate / [-] Glucose Standard Standard
Final filtration pore size 0.04 µm (40 nm) 0.22 µm 0.22 µm
Filtration stages 4 (Quadruple-stage) 1 1
Mycoplasma-retentive filtration check_circle cancel cancel
Endotoxin (release specification) < 0.05 EU/mL Corning classical liquid media — < 0.25 EU/mL
Sigma-Aldrich DMEM complete medium — ≤ 2 EU/mL
Gibco classical DMEM — Not specified (recorded per lot)
USP <788> Method 1 particulate compliance check_circle cancel cancel
Water quality Ultrapure Type 1, 18.2 MΩ·cm Unspecified Unspecified
Manufacturing QMS ISO 13485:2016 Varies Varies
Microfluidic channel compatibility check_circle cancel cancel
Custom formulation check_circle On request cancel cancel

Comparison figures from published supplier specifications, accessed 2026-09-02. Suppliers that publish no numeric endotoxin specification are shown as "Not specified".

FAQ

Frequently asked questions

Common questions about FluxMPS™ Dulbecco's Modified Eagle Medium (DMEM), 25mM HEPES w/o Glucose: 1X Liquid (DCP-DMEMH-G1X).

Yes. DCP-DMEMH-G1X is engineered for organ-on-a-chip, microfluidic, and microphysiological system (MPS) applications. The 0.04 µm final filtration removes fine particulates and microaggregates that cause microchannel clogging in standard 0.22 µm media.
Four sequential stages (0.1 µm → 0.04 µm → 0.1 µm → 0.04 µm) provide 0.1 µm mycoplasma-retentive filtration (mycoplasma typical diameter 0.2–0.3 µm) and reduce sub-visible particulate load beyond conventional 0.22 µm filters, consistent with USP <788> Method 1 (Light Obscuration Particle Count Test) particulate control.
DCP-DMEMH-G1X is formulated without glucose to enable precise metabolic control — including Warburg-effect studies, glycolysis inhibition, and ¹³C carbon-source tracing. Add D-glucose at your desired concentration (typically 1–4.5 g/L) or substitute galactose. Sodium pyruvate (110 mg/L) is already present as an alternate carbon source. Contact support@diagnocine.com for pre-supplemented variants.
DCP-DMEMH-G1X contains sodium bicarbonate (3700 mg/L), formulated for approximately 10% CO2 to maintain physiological pH 7.4. The added 25 mM HEPES provides supplemental buffering capacity for shorter bench-top handling outside the incubator. For CO2-independent use, request the bicarbonate-free variant.
DCP-DMEMH-G1X is a basal medium fully compatible with FBS (2–10%), human serum, EGF, FGF, VEGF, and antibiotics. Pre-filter serum and protein-containing additions through a 0.2 µm low-protein-binding PES or PVDF syringe filter before combining, to protect microchannel and biosensor compatibility.
Endotoxin is controlled per manufacturing batch rather than per unit. Every batch is tested by LAL assay (USP <85> Bacterial Endotoxins Test; assay sensitivity 0.005 EU/mL) and must meet the release specification of < 0.05 EU/mL before release. A Certificate of Analysis is available on request at support@diagnocine.com.
Yes — full CoA per lot includes: lot number, expiry, appearance, pH (USP <791>), osmolality (USP <785>), endotoxin (USP <85>), sterility (USP <71>), and particulate count (USP <788> Method 1). Email support@diagnocine.com.
Scientific References

Supporting literature

  1. Huh D, et al. Reconstituting organ-level lung functions on a chip. Science. 2010;328:1662–1668. doi:10.1126/science.1188302
  2. Bhatia SN, Ingber DE. Microfluidic organs-on-chips. Nat Biotechnol. 2014;32:760–772. doi:10.1038/nbt.2989
  3. Vander Heiden MG, et al. Understanding the Warburg effect. Science. 2009;324:1029–1033. doi:10.1126/science.1160809
  4. Sontheimer-Phelps A, et al. Modelling cancer in microfluidic human organs-on-chips. Nat Rev Cancer. 2019;19:65–81. doi:10.1038/s41568-018-0104-6
  5. van Duinen V, et al. Microfluidic 3D cell culture. Curr Opin Biotechnol. 2015;35:118–126. doi:10.1016/j.copbio.2015.05.002
  6. Jang KJ, et al. Reproducing human drug toxicities using a Liver-Chip. Sci Transl Med. 2019;11:eaax5516. doi:10.1126/scitranslmed.aax5516
  7. Kasendra M, et al. Primary human Small Intestine-on-a-Chip. Sci Rep. 2018;8:2871. doi:10.1038/s41598-018-21201-7
  8. Skardal A, et al. Multi-tissue organ-on-a-chip platform. Sci Rep. 2017;7:8837. doi:10.1038/s41598-017-08879-x

Satisfaction
Quality Rating
Value Rating
Style Rating
X