Until April 3rd, enjoy amazing savings!
Accuris™ Smart-Q™ Mini Fluorometer, 115V
Cat. No.: BM-F0100
Features:
- Compact Design: 3.27 x 3.27 in. footprint
- Two-channels: Blue (470 nm) and red (620 nm) excitation wavelengths
- Fast and Accurate: Quantification in under 5 seconds
- Minimal Sample Input: Requires as little as 1 μL
- Easy to Operate: Control via a Bluetooth®-connected tablet or smartphone (iOS or Android)
Description:
The Smart-Q Mini is a one-of-a-kind, benchtop fluorometer for quantitative measurement of DNA, RNA, ssDNA, and protein. The instrument is compact and conveniently operated via a smartphone or tablet and provides accurate results in under 5 seconds.
![]() |
Smart-Q Mini App |
![]() ![]() |
Standard Curve Generation and Molarity Calculation: The instrument supports both the use of pre-existing calibration curves and the creation of new two-point calibration curves (left). An integrated molarity calculator enables precise determination of dilution factors and final concentrations, facilitating accurate sample preparation for downstream applications (right). |
![]() ![]() |
Main App Interface and Experiment Run Screen: The Smart-Q Mini app enables users to select the desired experiment type and optionally generate a calibration curve. Once an experiment is defined, users input experimental parameters for both standards and unknown samples, after which the app automatically quantifies sample concentrations with high accuracy and reproducibility. |
| Accuris Quantification Kits Compatible with Smart-Q(TM) Mini and Qubit(TM) Accuris quantification kits are formulated to deliver highly accurate, sensitive, and reproducible measurement of nucleic acids. They provide a robust alternative to traditional absorbance-based methods. Each kit incorporates optimized fluorescence dye chemistry that selectively binds to DNA, RNA, or ssDNA targets, delivering exceptional sensitivity—even for samples with extremely low or near-negligible concentrations. |
=============================================================
Smart-Q Fluorometer, for quantification of DNA, RNA and protein samples
- Sensitive quantitation down to 0.1pg/ul ds DNA
- Large color touch screen for programming and operation
- Two models for single or 8-sample processing
- Built-in reagent calculators for sample preparation
- Compact and portable (11 x 6 inch footprint)
Smart-Q Specifications
| Model | Smart-Q™ Mini 115V |
|---|---|
| Display | No external display (instrument operation via iOS/Android phone or tablet) |
| Dynamic Range | 5 orders of magnitude |
| Light Source | Blue and Red LED |
| Excitation Wavelengths | Blue: 470 ± 15 nm Red: 620 ± 20 nm |
| Emission Wavelengths | Green: 525 – 570nm and Red: 670 – 725nm |
| Stability | ≤1.5% |
| Detector | Photodiodes (320-1100nm) |
| Measurement Speed | ≤ 5 seconds |
| Consumable type | 0.5 mL optically-clear quantification tubes |
| Input Voltage | 115V |
| Dimensions (WxDxH) | 3.27 x 3.27 x 3.62 in. / 8.13 x 8.13 x 3.19 cm |
| Weight | 0.5kg / 1.1lbs |
| Order | Current page |
Description
![]() |
The Accuris™ Smart-Q™ 100 & Smart-Q™ 800 Fluorometers are designed for the precise quantification of DNA, RNA, and protein samples. By utilizing well-established methodologies for fluorescence detection, the Smart-Q Fluorometers provide higher specificity and enhanced accuracy compared to the traditional method of UV-absorbance detection. Accurate results are particularly crucial in workflows involving:
ssDNA Quantification KitThe Accuris ssDNA Kit provides a simple and accurate method for quantifying single-stranded DNA (ssDNA) or oligonucleotides. The assay kit is accurate at detecting ssDNA between 0.05-200 ng/µL. While the kit is not selective for ssDNA over double-stranded DNA (dsDNA) or RNA, it does not detect contaminating proteins or nucleotides. Additionally, the kit demonstrates insensitivity to low concentrations of common contaminants such as proteins, salts, solvents, and detergents RNA High Sensitivity Quantification KitThe Accuris RNA High Sensitivity Quantification Kit offers a reliable and accurate method for measuring RNA concentration. This assay is highly selective for RNA over double-stranded and single-stranded DNA and can detect RNA concentrations ranging from 0.1 ng/μL to 100 ng/μL RNA Broad Range Quantification KitThe Accuris RNA Broad Range Quantification Kit enables precise and reliable RNA quantification. This assay exhibits high specificity for RNA over single stranded and double-stranded DNA, allowing for the detection of RNA concentrations ranging from 1 ng/μL to 1000 ng/μL. This assay demonstrates robustness against common contaminants, including proteins, free nucleotides, salts, solvents, and detergents |
![]() |
|
![]() |
|
| Smart-Q 100 for single sample processing | |
![]() |
|
| Smart-Q 800 for up to 8-sample processing | |
![]() |
|
| Accuris DNA Quantification Kits | |
![]() |
Ordering Information
* Request your price Quote

.png)