FluxMPS™ RPMI 1640 Medium with 25mM HEPES w/o Sodium Pyruvate: 1X Liquid

Product#: DCP-RPMIH-P1X
$44.00
DCP-RPMIH-P1X
Availability:
Ships in 1-2 Weeks

warning For Research Use Only (RUO). Not intended for clinical, diagnostic, or therapeutic use in humans.
verified ISO 13485 Certified Manufacturing

FluxMPS™ RPMI 1640 Medium with 25mM HEPES w/o Sodium Pyruvate: 1X Liquid

Contains L-Glutamine Contains Sodium Bicarbonate Contains Phenol Red Contains HEPES (25 mM) Contains Calcium Contains Magnesium Contains Glucose (2 g/L) Without Sodium Pyruvate

FluxMPS™ DCP-RPMIH-P1X is a Microfluidics Suitable, quadruple-stage ultra-filtered (0.1 µm ×2 + 0.04 µm ×2) RPMI 1640 + 25mM HEPES formulation engineered for hematopoietic and lymphocyte cell models on organ-on-a-chip (OoC) and microphysiological system (MPS) platforms. The train reaches a 0.04 µm final cut-off, five times finer than the 0.22 µm membranes used for conventional sterile filtration. HEPES (25 mM, pKa 7.3 at 37°C) supplements the sodium bicarbonate buffering system for pH stability during open-bench handling. Sodium pyruvate is withheld by design so researchers can define their own carbon/OXPHOS substrate levels.

  • High-glucose (2 g/L) RPMI 1640 base with 25 mM HEPES (pKa 7.3 at 37°C) for robust pH buffering during open-bench handling and flow cytometry prep
  • Sodium pyruvate omitted by design — researcher-defined addition (typically 1 mM) supports OXPHOS and metabolic flux studies in T cells and lymphoma lines
  • Reduced glutathione (1 mg/L) included for redox support in lymphocyte and hematopoietic cell culture
  • Quadruple-stage filtration (0.1 µm ×2 + 0.04 µm ×2) reaches a 0.04 µm final cut-off — five times finer than 0.22 µm conventional filtration
  • Endotoxin release specification < 0.05 EU/mL (LAL, USP <85>) to minimize TLR4-mediated activation artifacts in immune cell assays
  • Manufactured under an ISO 13485:2016 quality management system with a per-lot Certificate of Analysis
  • Phenol red included (5.3 mg/L) for visual pH monitoring; a phenol red-free variant is available on request for autofluorescence-sensitive imaging
  • Custom pH, salts, and nutrient modifications available — contact support@diagnocine.com
CAT. NO.
DCP-RPMIH-P1X | Cell Culture Media UNSPSC: 41116155 | Commodity: Molecular biology and cell culture growth media | (UNv260801)
RPMI 1640 + 25mM HEPES (w/o Sodium Pyruvate) — 1X Liquid
  • Glucose2000 mg/L (2.0 g/L)
  • L-Glutamine300 mg/L
  • Sodium PyruvateNot added — researcher-defined addition
  • pH (USP <791>)7.4
  • Osmolality (USP <785>)280–320 mOsm/kg H2O
  • Endotoxin (USP <85>)< 0.05 EU/mL
  • Filtration0.1 µm ×2 + 0.04 µm ×2 (Quadruple-stage)
  • Storage2–8°C, protect from light
  • Shelf Life12 months from date of manufacture, unopened
  • ShippingCold pack
ISO 13485:2016 USP <85> <785> <788> RUO

Available pack sizes: 500 mL, 1000 mL.

Why FluxMPS™

Engineered where standard media fails

Conventional 0.22 µm–filtered RPMI passes mycoplasma-sized particles, subvisible particulates, and endotoxin fragments that can confound sensitive immune cell assays. FluxMPS™ is built around a finer filtration train to reduce these risks.

filter_alt

Microchannel-safe purity

0.04 µm final-stage filtration with USP <788> Method 1 particulate compliance (NMT 25/mL ≥10 µm, NMT 3/mL ≥25 µm) — supports suspension immune cell OoC and flow cytometry workflows.

target

Total metabolic control

Sodium pyruvate is withheld so researchers can define their own carbon and OXPHOS substrate levels for T cell and lymphoma metabolic flux studies, without a pre-set pyruvate background.

water_drop

Ultrapure-grade water

Prepared with Type 1 water (18.2 MΩ·cm) under controlled trace-metal and total organic carbon limits, supporting consistent lot-to-lot performance in sensitive lymphocyte cultures.

visibility

Low background for imaging

0.04 µm filtration reduces particulate background for flow cytometry and confocal microscopy. This formulation contains phenol red (5.3 mg/L); a phenol red-free variant is available on request for autofluorescence-sensitive PE-channel and biosensor applications.

science

Rich, stable nutrient profile

RPMI 1640 base with reduced glutathione, 20 amino acids and 11 vitamins, released on a per-lot, micro-batch basis with a full Certificate of Analysis.

tune

Customization on demand

pH, HEPES concentration, salts, and nutrient composition available on request. Contact support@diagnocine.com.

Purity Architecture

Quadruple-stage filtration system

Four serial filtration stages — two dedicated prefilter + final-filter pairs — reaching a final 0.04 µm polish.

  1. 1

    0.1 µm Prefiltration I

    Removes large aggregates and cell debris; protects the first 0.04 µm cartridge.

  2. 2

    0.04 µm Final filtration I

    First 0.04 µm pass; retains sub-micron particulates that pass a 0.22 µm filter.

  3. 3

    0.1 µm Prefiltration II

    Second dedicated prefilter, protecting the second 0.04 µm cartridge.

  4. 4

    0.04 µm Final filtration II — Polish

    Ultimate polishing filter; aseptic fill in an ISO Class 5 (Class 100) environment.

Performance vs. conventional media

A quadruple-stage train (0.1 µm ×2 + 0.04 µm ×2) reaches a 0.04 µm final cut-off, five times finer than the 0.22 µm membranes used for conventional sterile filtration, with 0.1 µm mycoplasma-retentive filtration built into two points of the train.

5×
Finer final pore size (0.04 µm) than conventional 0.22 µm filtration
4
Sequential filtration passes (0.1 µm ×2 + 0.04 µm ×2)
Sterility & Mycoplasma: No growth after 14-day incubation (USP <71>); 0.1 µm mycoplasma-retentive filtration (not tested per lot).
Grade: This product is Microfluidics Suitable, filtered to a 0.04 µm final cut-off. It is not an MPS Grade product — that designation is reserved for the 0.01 µm ultra nano-filtered line, which adds 0.02 µm and 0.01 µm stages after the 0.04 µm polish. For applications requiring the 0.01 µm cut-off, contact support@diagnocine.com.
FluxMPS DCP-RPMIH-P1X RPMI 1640 25mM HEPES quadruple-stage filtration system 0.1 micron x2 plus 0.04 micron x2 for organ-on-a-chip and microfluidic immune cell culture, Diagnocine
Figure 1. FluxMPS™ Quadruple-stage filtration system (0.1 µm ×2 + 0.04 µm ×2).
© Diagnocine® — DCP-RPMIH-P1X
Applications

Immune cell OoC and hematopoietic applications

FluxMPS™ DCP-RPMIH-P1X — RPMI 1640 + 25mM HEPES — delivers 0.04 µm filtered purity for hematopoietic cell and related OoC applications.

Automated Bioreactors & Robotics

Next-Generation System Uptime

Optional 0.01 µm (10 nm) ultra-filtered MPS Grade variant available on request for automated, closed-loop bioreactor systems.

  • Total Particulate Exclusion: 10 nm filtration removes nanoparticulate aggregates
  • Valve & Sensor Protection: Reduces micro-fouling risk in automated perfusion systems
  • Extended Perfusion Stability: Consistent nutrient delivery over long-duration culture

Inquiry Required: Contact support@diagnocine.com for the 0.01 µm MPS Grade variant.

Immunology

T Cell & Lymphocyte Culture

RPMI 1640 is the standard base for primary T cells, B cells, NK cells, and monocytes. FluxMPS 0.04 µm filtration reduces particulate load in immune cell assays.

T cellsB cellsNK cellsPBMC
Cancer Biology

Leukemia & Lymphoma Lines

RPMI supports NCI-60 cancer lines, Jurkat, Raji, K562, HL-60, and other hematopoietic cancer lines where DMEM would alter proliferation and signaling.

JurkatRajiK562HL-60
Microfluidics

Immune Cell OoC

0.04 µm filtered RPMI for tumor-immune interaction chips, vascular-immune OoC, and lymph-node-on-chip models.

Tumor-immune chipLymph node OoCMPS
Immunotherapy

CAR-T & TIL Expansion

Low endotoxin release specification (< 0.05 EU/mL) supports CAR-T manufacturing and TIL expansion protocols sensitive to TLR4 activation.

CAR-TTILTCR-T
Metabolomics

Immune Cell Metabolic Flux

Defined RPMI 1640 + HEPES base with researcher-controlled pyruvate addition, suited to 13C isotope tracing and glycolysis flux studies of lymphocyte activation states. Not compatible with Agilent Seahorse XF assays, which require bicarbonate-free, phenol red-free medium.

13C tracingGlycolysis
Live-Cell Imaging

Flow Cytometry & Confocal

Ultra-low particulate media suited to flow cytometry and confocal imaging of immune cells. This formulation contains phenol red; ask about our phenol red-free variant for autofluorescence-sensitive PE-channel and biosensor applications.

Flow cytometryConfocalELISA
Technical Specifications

Analytical release specifications

Every lot released against the full specification matrix. CoA: support@diagnocine.com.

Physical & Chemical Parameters
Parameter Specification
Formulation [+] L-Glutamine, [+] Sodium Bicarbonate, [+] Phenol Red, [+] HEPES (25 mM), [+] Calcium, [+] Magnesium, [+] Glucose (2 g/L) | [-] Sodium Pyruvate
Appearance Red-colored, clear solution
Glucose 2000 mg/L (2.0 g/L)
L-Glutamine 300 mg/L
Sodium Pyruvate Not added
Phenol Red 5.3 mg/L
pH USP <791> 7.4
Osmolality USP <785> 280–320 mOsm/kg H2O
Total ingredients 41
Sterility, Purity & Safety
Parameter Specification
Endotoxin USP <85> BET < 0.05 EU/mL
Sterility USP <71> No growth / 14 days
Mycoplasma 0.1 µm mycoplasma-retentive filtration (not tested per lot)
Particulate ≥10 µm USP <788> Method 1 NMT 25/mL
Particulate ≥25 µm USP <788> Method 1 NMT 3/mL
Water purity Type 1, 18.2 MΩ·cm
Manufacturing std. ISO 13485:2016
Fill environment ISO Class 5 (Class 100)
Storage, Handling & Logistics
Parameter Specification
Storage temperature 2–8°C, away from light
Freeze-thaw Do not freeze
Shelf life 12 months from date of manufacture, unopened
Shipping condition Cold pack
CO2 requirement 5% CO2 recommended. Sodium bicarbonate (2 g/L, ~23.8 mM) provides the primary buffering system; 25 mM HEPES supplements pH stability during open-bench handling.
Raw Materials & Regulatory
Parameter Specification
Raw material grade Reagent / cell culture grade
Traceability Full lot traceability per ISO 13485
Manufacturing QMS ISO ISO 13485:2016 certified
UNSPSC 41116155 — Molecular biology and cell culture growth media (UNv260801)
Regulatory alignment 21 CFR Part 820 (QMSR) aligned
Production method Micro-batch, per-lot QC release
Intended use Research Use Only (RUO)
Formulation

Full composition (mg/L)

RPMI 1640 + 25mM HEPES: 41 ingredients verified per lot with CAS numbers for full raw-material traceability. Contains reduced glutathione and a balanced profile of vitamins and amino acids optimized for lymphocyte and hematopoietic cell culture.

Component CAS Number mg/L
INORGANIC SALTS
Calcium nitrate tetrahydrate 13477-34-4 100.000
Magnesium sulfate anhydrous 7487-88-9 48.840
Potassium chloride 7447-40-7 400.000
Sodium bicarbonate 144-55-8 2000.000
Sodium chloride 7647-14-5 6000.00
Sodium phosphate dibasic anhydrous 7558-79-4 800.000
Component CAS Number mg/L
AMINO ACIDS
Glycine 56-40-6 10.000
L-Arginine hydrochloride 1119-34-2 241.000
L-Asparagine 70-47-3 50.000
L-Aspartic acid 56-84-8 20.000
L-Cystine dihydrochloride 30925-07-6 65.200
L-Glutamic acid 56-86-0 20.000
L-Glutamine 56-85-9 300.000
L-Histidine hydrochloride monohydrate 5934-29-2 20.960
L-Hydroxyproline 51-35-4 20.000
L-Isoleucine 73-32-5 50.000
L-Leucine 61-90-5 50.000
L-Lysine hydrochloride 657-27-2 40.000
L-Methionine 63-68-3 15.000
L-Phenylalanine 63-91-2 15.000
L-Proline 147-85-3 20.000
L-Serine 56-45-1 30.000
L-Threonine 72-19-5 20.000
L-Tryptophan 73-22-3 5.000
L-Tyrosine Disodium Salt 69847-45-6 28.830
L-Valine 72-18-4 20.000
Component CAS Number mg/L
VITAMINS
Choline chloride 67-48-1 3.000
D-Biotin 58-85-5 0.200
D-Ca-Pantothenate 137-08-6 0.250
Folic acid 59-30-3 1.000
Niacinamide 98-92-0 1.000
Pyridoxine hydrochloride 58-56-0 1.000
Riboflavin 83-88-5 0.200
Thiamine hydrochloride 67-03-8 1.000
Vitamin B12 68-19-9 0.005
i-Inositol 87-89-8 35.000
p-Amino benzoic acid (PABA) 150-13-0 1.000
OTHERS
D-Glucose 50-99-7 2000.000
Glutathione reduced 70-18-8 1.000
HEPES 7365-45-9 5958.00
Phenol red sodium salt 34487-61-1 5.300
Custom formulation: Contact support@diagnocine.com for DCP-RPMIH-P1X modifications.
Quality Assurance

Manufacturing & compliance

Every FluxMPS™ product is manufactured and released under a multi-layer quality system.

verified

ISO 13485:2016 Quality Management

Manufactured under ISO 13485:2016-certified facilities. Final QC at the Diagnocine R&D Center, Totowa, NJ, USA.

water_drop

Ultrapure Type 1 Water

Type 1 water (18.2 MΩ·cm) with controlled trace-metal and total organic carbon limits.

biotech

ISO Class 5 Fill & Finish

Aseptic fill in validated ISO Class 5 (Class 100) laminar-flow workstations.

assignment

Micro-Batch Precision

Small-batch, per-lot tested — no blending; Certificate of Analysis for every lot.

Endotoxin — USP <85> BET

LAL assay; batch release specification < 0.05 EU/mL.

Particulate — USP <788> Method 1

NMT 25/mL (≥10 µm), NMT 3/mL (≥25 µm).

Osmolality — USP <785>

Target: 280–320 mOsm/kg H2O.

Documentation & CoA

Full CoA with raw-material traceability available on request.

Batch-level quality control. Endotoxin is controlled per manufacturing batch rather than per unit. Every batch is tested before release and must meet the release specification:
  • Endotoxin — LAL assay, USP <85> Bacterial Endotoxins Test; assay sensitivity 0.005 EU/mL; release specification < 0.05 EU/mL
  • pH, osmolality, conductivity, appearance and clarity
  • Sterility
A Certificate of Analysis is available on request.
Certificate of Analysis: Request for any DCP-RPMIH-P1X lot at support@diagnocine.com.
Product Comparison

How DCP-RPMIH-P1X compares

FluxMPS™ DCP-RPMIH-P1X vs. conventional 0.22 µm–filtered RPMI formulations.

Parameter DCP-RPMIH-P1X (FluxMPS™) Conventional RPMI 1640 + 25mM HEPES (0.22 µm filtered) Standard DMEM/RPMI (0.22 µm filtered)
Grade Microfluidics Suitable Standard (no filtration grade) Standard (no filtration grade)
RPMI 1640 + 25mM HEPES, pyruvate-free with researcher-defined carbon control check_circle Yes cancel No cancel No
Final filtration pore size 0.04 µm 0.22 µm 0.22 µm
Number of filtration stages 4 (Quadruple-stage) 1 1
Mycoplasma-retentive filtration (0.1 µm) check_circle Yes cancel No cancel No
Endotoxin (release specification) < 0.05 EU/mL Corning classical liquid media — < 0.25 EU/mL
Sigma-Aldrich DMEM complete medium — ≤ 2 EU/mL
Gibco classical DMEM — Not specified (recorded per lot)
USP <788> Method 1 particulate tested check_circle Yes cancel No cancel No
Water quality Type 1, 18.2 MΩ·cm Purified water Purified water
Manufacturing QMS ISO 13485:2016 ISO 9001 or none ISO 9001 or none
Microfluidic channel compatibility check_circle Yes (0.04 µm cut-off) cancel Risk of clogging cancel Risk of clogging
Custom formulation check_circle Yes cancel No cancel No

Comparison figures from published supplier specifications, accessed 2026-09-02. Suppliers that publish no numeric endotoxin specification are shown as "Not specified".

FAQ

Frequently asked questions

Common questions about FluxMPS™ DCP-RPMIH-P1X — RPMI 1640 + 25mM HEPES.

Yes. DCP-RPMIH-P1X is processed through a Quadruple-stage filtration system reaching a 0.04 µm final pore size and is Microfluidics Suitable. RPMI 1640 with 0.1 µm mycoplasma-retentive filtration is suited to immune cell OoC, tumor-immune interaction chips, and lymphocyte perfusion models.
FluxMPS™ uses four sequential filters — 0.1 µm prefiltration I, 0.04 µm final filtration I, 0.1 µm prefiltration II, and 0.04 µm final filtration II (polish) — reaching a 0.04 µm final cut-off, five times finer than the 0.22 µm membranes used in conventional filtration, with 0.1 µm mycoplasma-retentive filtration built into the train.
Sodium pyruvate is omitted so researchers can add it fresh at a defined concentration (typically 1 mM). HEPES (25 mM) plus sodium bicarbonate maintain pH stability during the addition. This is commonly used for T cell and lymphoma OXPHOS studies where pyruvate concentration is an experimental variable.
5% CO2 is recommended. Sodium bicarbonate (2 g/L, ~23.8 mM) provides the primary buffering system; 25 mM HEPES supplements pH stability during open-bench handling and imaging outside the incubator.
Yes. Add FBS (5–10%), serum-free supplements, growth factors, or antibiotics as required. When pre-filtering serum or protein-containing additions, use a 0.2 µm low-protein-binding PES or PVDF filter — never a 0.04 µm membrane, which will strip serum proteins and clog. Contact support@diagnocine.com for custom co-formulation.
Endotoxin is controlled per manufacturing batch, not per unit. Every batch is tested by LAL assay (USP <85>, assay sensitivity 0.005 EU/mL) and must meet the release specification of < 0.05 EU/mL before release. A Certificate of Analysis is available on request.
Yes. Full CoA per lot covers: appearance, pH (USP <791>), osmolality (USP <785>), sterility (USP <71>), endotoxin (USP <85>), mycoplasma-retentive filtration status, particulate count (USP <788> Method 1), and raw-material traceability. Request at support@diagnocine.com.
Scientific References

Supporting literature

Key publications supporting RPMI 1640 + 25mM HEPES in immune cell culture and OoC applications.

  1. Moore GE, et al. Culture of normal human leukocytes. JAMA. 1967;199:519–524. doi:10.1083/jcb.1.3.273
  2. Huh D, et al. Reconstituting organ-level lung functions on a chip. Science. 2010;328:1662–1668. doi:10.1126/science.1188302
  3. Bhatia SN, Ingber DE. Microfluidic organs-on-chips. Nat Biotechnol. 2014;32:760–772. doi:10.1038/nbt.2989
  4. Novak R, et al. Robotic fluidic coupling and interrogation of multiple vascularized organ chips. Nat Biomed Eng. 2020;4:407–420. doi:10.1038/s41551-019-0497-x
  5. Jang KJ, et al. Human kidney proximal tubule-on-a-chip. Integr Biol. 2013;5:1119–1129. doi:10.1039/c3ib40049b
  6. Schimek K, et al. Integrating biological vasculature into a multi-organ-chip microsystem. Lab Chip. 2013;13:3588–3598. doi:10.1039/c3lc50217a
  7. Luni C, et al. High-efficiency cellular reprogramming with microfluidics. Nat Methods. 2016;13:446–452. doi:10.1038/nmeth.3832
  8. Sung JH, et al. Microfabricated mammalian organ systems. Lab Chip. 2013;13:1201–1212. doi:10.1039/c3lc41017j

Satisfaction
Quality Rating
Value Rating
Style Rating
X