FluxMPS™ RPMI 1640 Medium, High Glucose & 25mM HEPES w/o Sodium Pyruvate, Sodium Bicarbonate: 1X Liquid

Contains L-Glutamine Contains Phenol Red Contains 25mM HEPES Contains Calcium Contains Magnesium Contains High Glucose Without Sodium Bicarbonate Without Sodium Pyruvate

FluxMPS™ DCP-RPMIGH-PB1X is a Microfluidics Suitable, quadruple-stage ultra-filtered (0.1 µm ×2 + 0.04 µm ×2) 1X liquid RPMI 1640 medium engineered for organ-on-a-chip (OoC) and microphysiological system (MPS) platforms. A quadruple-stage train (0.1 µm ×2 + 0.04 µm ×2) reaches a 0.04 µm final cut-off, five times finer than the 0.22 µm membranes used for conventional sterile filtration.

  • Quadruple-stage filtration system (0.1 µm ×2 + 0.04 µm ×2) reaching a 0.04 µm final polish
  • High glucose RPMI 1640 base (4500 mg/L) with 300 mg/L L-glutamine and 25 mM HEPES buffering
  • Formulated without sodium pyruvate and without sodium bicarbonate — HEPES-buffered for reduced CO₂ dependence
  • Endotoxin specification: < 0.05 EU/mL (LAL, USP <85>)
  • Manufactured under an ISO 13485:2016 quality management system with full lot traceability
  • Ultrapure Type 1 water (18.2 MΩ·cm); ISO Class 5 (Class 100) aseptic fill & finish
  • Custom pH, glucose, HEPES and salt modifications available on request
CAT. NO.
DCP-RPMIGH-PB1X | Cell culture media UNSPSC: 41116155 | Commodity: Molecular biology and cell culture growth media | (UNv260801)
RPMI 1640 Medium, High Glucose & 25mM HEPES w/o Sodium Pyruvate, Sodium Bicarbonate: 1X Liquid
  • Formulation[+] L-Glutamine, [+] Phenol Red, [+] 25mM HEPES, [+] Calcium, [+] Magnesium, [+] High Glucose, [-] Sodium Bicarbonate, [-] Sodium Pyruvate
  • Glucose4500.000 mg/L
  • L-Glutamine300.000 mg/L
  • pH (USP <791>)7.4
  • Osmolality (USP <785>)Contact for specification
  • Endotoxin (USP <85>)< 0.05 EU/mL
  • FiltrationQuadruple-stage: 0.1 µm ×2 + 0.04 µm ×2
  • Storage2–8°C, protect from light
  • Shelf Life12 months from date of manufacture, unopened
  • Available Sizes500 mL, 1000 mL
ISO 13485:2016 USP <85> <785> <788> RUO
Why FluxMPS™

Engineered where standard media fails

Conventional 0.22 µm–filtered media passes mycoplasma-sized particles, subvisible particulates, and microaggregates that confound microfluidic assays.

filter_alt

Microchannel-safe purity

0.04 µm final filtration; USP <788> Method 1 (light obscuration) particulate compliance. Built for particle-sensitive OoC microfluidic chips.

target

Total metabolic control

Defined formulation for precise control of carbon sources, nutrients, and metabolic inputs in your experimental system.

water_drop

Ultrapure-grade water

Manufactured with Type 1 water (18.2 MΩ·cm resistivity) for tight trace-metal and organic-carbon (TOC) control at the source.

visibility

Low background for imaging

Ultra-low particulate baseline suited to confocal microscopy, biosensor readouts, and live-cell imaging on-chip.

science

Rich, stable nutrient profile

39 verified ingredients per lot. Full CAS traceability. Micro-batch precision manufacturing.

tune

Customization on demand

pH, nutrient concentrations, HEPES, and component modifications available. Contact support@diagnocine.com.

Purity Architecture

Quadruple-stage filtration system

Four serial filtration stages — two dedicated prefilter/final-filter pairs — reaching a final 0.04 µm polish under ISO Class 5 aseptic conditions.

  1. 1

    0.1 µm Prefiltration I — Large Particulate Removal

    Removes large aggregates and debris; protects the first 0.04 µm final filter cartridge and extends its service life.

  2. 2

    0.04 µm Final filtration I — Sub-mycoplasma Polishing

    Provides a sub-mycoplasma (0.2–0.3 µm) filtration barrier beyond the standard 0.1 µm mycoplasma-retentive grade; a filtration-based control, not a per-lot test result.

  3. 3

    0.1 µm Prefiltration II — Second-pass Redundancy

    A second, dedicated prefilter protecting the second 0.04 µm final filter cartridge across the full batch volume.

  4. 4

    0.04 µm Final filtration II — Polish

    Ultimate polishing filter; ISO Class 5 (Class 100) aseptic fill & finish. Final product QC release gate.

Performance vs. conventional media

5×
Cleaner than 0.22 µm media by particulate count
4
Filtration passes to a 0.04 µm final pore size
Sterility & Mycoplasma: No growth after 14-day incubation (USP <71>); 0.1 µm mycoplasma-retentive filtration at every stage (not tested per lot).
Grade: This product is Microfluidics Suitable, filtered to a 0.04 µm final cut-off. It is not an MPS Grade product — that designation is reserved for the 0.01 µm ultra nano-filtered line, which adds 0.02 µm and 0.01 µm stages after the 0.04 µm polish. For applications requiring the 0.01 µm cut-off, contact support@diagnocine.com.
FluxMPS™ DCP-RPMIGH-PB1X Quadruple-stage filtration system Diagnocine RPMI 1640 organ-on-a-chip microfluidic cell culture media
Figure 1. FluxMPS™ Quadruple-stage filtration system (0.1 µm ×2 + 0.04 µm ×2) — DCP-RPMIGH-PB1X.
© Diagnocine® — DCP-RPMIGH-PB1X
Applications

OoC and MPS Applications

FluxMPS™ DCP-RPMIGH-PB1X delivers ultra-filtered, Microfluidics Suitable purity for organ-on-a-chip and microfluidic applications.

Automated Bioreactors & Robotics

Next-Generation System Uptime

An optional 0.01 µm (10 nm) ultra nano-filtered MPS Grade variant is available on request for automated bioreactors and robotic perfusion systems.

  • Total Particulate Exclusion: 10 nm filtration removes nanoparticulate aggregates that foul automated systems
  • Valve & Sensor Protection: Reduces micro-fouling risk in automated perfusion and recirculation systems
  • Extended Perfusion Stability: Consistent nutrient delivery over long-duration culture runs

Inquiry Required: Contact support@diagnocine.com to request the 0.01 µm MPS Grade variant.

Microfluidics

Micro Physiological System (MPS) & Chip

0.04 µm filtered media for organ-on-a-chip, tissue-on-a-chip, and body-on-a-chip where particle-free media prevents channel fouling.

OoCToCBoCLoCMPS
Cancer Biology

Cancer Cell Lines & Metabolic Research

Supports NCI-60 cancer lines and Warburg effect metabolic studies with precise nutrient control.

MCF-7MDA-MB-231HeLaJurkat
Stem Cell Biology

iPSC-Derived Models

Ultra-clean base for iPSC differentiation protocols requiring defined, particulate-free media.

iPSC-NeuronsiPSC-CMiPSC-Hep
Vascular Biology

Endothelial & Primary Cells

Particle-free formulation for primary cells and endothelial monolayer studies on-chip.

HUVECsHAECsPrimary hepatocytes
Metabolomics

Metabolic Flux Analysis

Defined formulation for ¹³C isotope tracing and NMR metabolomics. Not compatible with Agilent Seahorse XF assays, which require bicarbonate-free, phenol red-free medium.

¹³C tracingNMR metabolomics
Live-Cell Imaging

Microscopy & Optical Sensing

Low particulate background for confocal microscopy, biosensor measurements, and TEER monitoring on-chip.

ConfocalBiosensorsTEER
Technical Specifications

Analytical release specifications

Every lot released against the full specification matrix. Certificate of Analysis available: support@diagnocine.com.

Physical & Chemical Parameters
Parameter Specification
Formulation [+] L-Glutamine, [+] Phenol Red, [+] 25mM HEPES, [+] Calcium, [+] Magnesium, [+] High Glucose, [-] Sodium Bicarbonate, [-] Sodium Pyruvate
Appearance Red-colored, clear solution
Total ingredients 39
pH USP <791> 7.4
Osmolality USP <785> Contact for specification
Glucose 4500.000 mg/L
Sterility, Purity & Safety
Parameter Specification
Endotoxin USP <85> BET < 0.05 EU/mL
Sterility USP <71> No growth / 14 days
Mycoplasma 0.1 µm mycoplasma-retentive filtration (not tested per lot)
Particulate ≥10 µm USP <788> Method 1 NMT 25/mL
Particulate ≥25 µm USP <788> Method 1 NMT 3/mL
Water purity Type 1, 18.2 MΩ·cm
Manufacturing std. ISO ISO 13485:2016
Fill environment ISO Class 5 (Class 100)
Storage, Handling & Logistics
Parameter Specification
Storage temperature 2–8°C, protect from light
Freeze-thaw Do not freeze
Shelf life 12 months from date of manufacture, unopened
Shipping condition Cold pack
CO₂ requirement HEPES-buffered; reduced CO₂ dependence (validate per cell line)
Raw Materials & Regulatory
Parameter Specification
Raw material grade Reagent / cell culture grade
Traceability Full lot traceability per ISO 13485
Manufacturing QMS ISO ISO 13485:2016 certified
UNSPSC 41116155 — Molecular biology and cell culture growth media (UNv260801)
Regulatory alignment 21 CFR Part 820 (QMSR) aligned
Production method Micro-batch, per-lot QC release
Intended use Research Use Only (RUO)
Formulation

Full composition (mg/L)

RPMI 1640 Medium, High Glucose & 25mM HEPES w/o Sodium Pyruvate, Sodium Bicarbonate: 1X Liquid — 39 ingredients verified per lot with CAS numbers for full raw-material traceability. All ingredients from the original formulation are preserved exactly.

Component CAS Number mg/L
INORGANIC SALTS
Calcium nitrate tetrahydrate 13477-34-4 100.000
Magnesium sulfate anhydrous 7487-88-9 48.840
Potassium chloride 7447-40-7 400.000
Sodium chloride 7647-14-5 6000.000
Sodium phosphate dibasic anhydrous 7558-79-4 800.000
Component CAS Number mg/L
AMINO ACIDS
Glycine 56-40-6 10.000
L-Arginine hydrochloride 1119-34-2 241.000
L-Asparagine 70-47-3 50.000
L-Aspartic acid 56-84-8 20.000
L-Cystine dihydrochloride 30925-07-6 65.200
L-Glutamic acid 56-86-0 20.000
L-Glutamine 56-85-9 300.000
L-Histidine hydrochloride monohydrate 5934-29-2 20.960
L-Hydroxyproline 51-35-4 20.000
L-Isoleucine 73-32-5 50.000
L-Leucine 61-90-5 50.000
L-Lysine hydrochloride 657-27-2 40.000
L-Methionine 63-68-3 15.000
L-Phenylalanine 63-91-2 15.000
L-Proline 147-85-3 20.000
L-Serine 56-45-1 30.000
L-Threonine 72-19-5 20.000
L-Tryptophan 73-22-3 5.000
L-Tyrosine Disodium Salt 69847-45-6 28.830
L-Valine 72-18-4 20.000
Component CAS Number mg/L
VITAMINS
Choline chloride 67-48-1 3.000
D-Biotin 58-85-5 0.200
D-Ca-Pantothenate 137-08-6 0.250
Folic acid 59-30-3 1.000
Niacinamide 98-92-0 1.00
Pyridoxine hydrochloride 58-56-0 1.00
Riboflavin 83-88-5 0.200
Thiamine hydrochloride 67-03-8 1.000
p-Amino benzoic acid (PABA) 150-13-0 1.000
OTHERS
D-Glucose 50-99-7 4500.000
Glutathione reduced 70-18-8 1.000
HEPES 7365-45-9 5958.000
Phenol red sodium salt 34487-61-1 5.300
i-Inositol 87-89-8 35.000
Customization available: pH, glucose, HEPES, salts, and nutrient composition modifications available on request. Contact support@diagnocine.com.
Quality Assurance

ISO 13485 Manufacturing & Compliance

Every batch of FluxMPS™ DCP-RPMIGH-PB1X is manufactured under a certified ISO 13485:2016 QMS with full lot traceability and multi-parameter QC release testing.

verified

ISO 13485:2016 QMS

Full quality management system with documented procedures, deviation control, and CAPA. Every lot traceable from raw material to final release.

water_drop

Ultrapure Type 1 Water

18.2 MΩ·cm resistivity feedwater supports tight trace-metal and organic-carbon (TOC) control at the manufacturing source.

biotech

ISO Class 5 Fill & Finish

Final aseptic filling in ISO Class 5 (Class 100) cleanroom. Immediate post-filtration fill to reduce recontamination risk.

assignment

Micro-Batch Precision

Small-batch manufacturing with per-lot QC release. Every batch tested independently — not pooled or blended across lots.

Endotoxin USP <85> BET

LAL-based endotoxin test per manufacturing batch. Assay sensitivity 0.005 EU/mL. Release specification: < 0.05 EU/mL.

Particulate USP <788> Method 1

Light obscuration particulate analysis. NMT 25/mL at ≥10 µm; NMT 3/mL at ≥25 µm.

Osmolality USP <785>

Osmolality verified per lot using vapor pressure or freezing-point depression osmometry per USP <785>.

Documentation / CoA

Full Certificate of Analysis available per lot, including lot number and expiry date. Request: support@diagnocine.com.

Batch-level quality control. Endotoxin is controlled per manufacturing batch rather than per unit. Every batch is tested before release and must meet the release specification:
  • Endotoxin — LAL assay, USP <85> Bacterial Endotoxins Test; assay sensitivity 0.005 EU/mL; release specification < 0.05 EU/mL
  • pH, osmolality, conductivity, appearance and clarity
  • Sterility
A Certificate of Analysis is available on request at support@diagnocine.com.
Product Comparison

How DCP-RPMIGH-PB1X compares

FluxMPS™ versus conventional 0.22 µm filtered media for OoC and MPS applications.

Parameter DCP-RPMIGH-PB1X (FluxMPS™) Conventional 0.22 µm Filtered Standard Alternative
Grade Microfluidics Suitable Not applicable Not applicable
Formulation [+] L-Glutamine, [+] Phenol Red, [+] 25mM HEPES, [+] Calcium, [+] Magnesium, [+] High Glucose, [-] Sodium Bicarbonate, [-] Sodium Pyruvate Standard RPMI 1640 Standard RPMI 1640
Final filtration pore size 0.04 µm 0.22 µm 0.22 µm
Number of filtration stages 4 stages 1 stage 1–2 stages
Mycoplasma barrier filtration check_circle cancel cancel
Endotoxin (release specification) FluxMPS™ — < 0.05 EU/mL Corning classical liquid media — < 0.25 EU/mL
Sigma-Aldrich DMEM complete medium — ≤ 2 EU/mL
Gibco classical DMEM — Not specified (recorded per lot)
USP particulate compliance check_circle cancel cancel
Water quality Type 1, 18.2 MΩ·cm Type 2 typical Type 2 typical
Manufacturing QMS ISO 13485:2016 ISO 9001 typical Variable
Microfluidic channel compatibility check_circle cancel cancel
Custom formulation check_circle cancel Limited

Comparison figures from published supplier specifications, accessed 2026-09-02. Suppliers that publish no numeric endotoxin specification are shown as "Not specified".

FAQ

Frequently asked questions

Common questions about FluxMPS™ DCP-RPMIGH-PB1X and its use in OoC and MPS applications.

Yes. DCP-RPMIGH-PB1X is a Microfluidics Suitable medium engineered for MPS and OoC platforms. The 0.04 µm final filtration reduces microfluidic channel fouling, making it suitable for OoC, ToC, BoC, and LoC applications sensitive to particulate contamination.
FluxMPS uses a Quadruple-stage system (0.1 µm ×2 + 0.04 µm ×2), providing approximately 5× lower particulate counts and 0.1 µm mycoplasma-retentive filtration at every stage that standard 0.22 µm filtration does not provide.
This formulation is HEPES-buffered and does not include sodium pyruvate or sodium bicarbonate, giving you control over buffering strategy and carbon-source supplementation. Add sodium pyruvate or a bicarbonate buffering system to match your protocol; validate any addition against your specific cell line before use.
Not necessarily. This formulation is HEPES-buffered and free of sodium bicarbonate, giving reduced CO₂ dependence. Validate the appropriate incubation atmosphere for your specific cell line and protocol.
Yes. This is a basal medium formulation. Supplement with FBS, serum replacements, growth factors, or other additives as required. When filtering serum or protein-containing supplements, use a 0.2 µm low-protein-binding PES or PVDF filter — never a 0.04 µm membrane, which retains serum proteins and lipoproteins and will clog rapidly.
Endotoxin is controlled to a release specification of < 0.05 EU/mL, verified per manufacturing batch by the Limulus Amebocyte Lysate (LAL) assay per USP <85> (assay sensitivity 0.005 EU/mL). Every batch is tested before release; a Certificate of Analysis is available on request.
Yes. CoA is available per batch upon request at support@diagnocine.com. It includes lot number, expiry date, pH, osmolality, endotoxin, sterility, particulate (USP <788>) data, appearance, and full raw material lot traceability.
Scientific References

Supporting literature

Curated peer-reviewed references relevant to OoC and MPS applications and FluxMPS™ ultra-filtered cell culture media applications.

  1. Bhatia SN, Ingber DE. Microfluidic organs-on-chips. Nature Biotechnology. 2014;32(8):760–772.doi:10.1038/nbt.2989
  2. Sackmann EK, Fulton AL, Beebe DJ. The present and future role of microfluidics in biomedical research. Nature. 2014;507(7491):181–189.doi:10.1038/nature13118
  3. Huh D, et al. Reconstituting organ-level lung functions on a chip. Science. 2010;328(5986):1662–1668.doi:10.1126/science.1188302
  4. Ingber DE. Is it Time for Reviewer 3 to Request Human Organ Chip Experiments Instead of Animal Validation Studies? Advanced Science. 2020;7(22):2002162.doi:10.1002/advs.202002162
  5. Maoz BM, et al. A linked organ-on-chip model of the human neurovascular unit reveals the metabolic landscape of brain disease. Nature Biotechnology. 2018;36:865–874.doi:10.1038/nbt.4226
  6. Bhise NS, et al. A liver-on-a-chip platform with bioprinted hepatic spheroids. Biofabrication. 2016;8(1):014101.doi:10.1088/1758-5090/8/1/014101
  7. Luni C, Serena E, Elvassore N. Human-on-chip for therapy development and fundamental science. Current Opinion in Biotechnology. 2014;25:45–50.doi:10.1016/j.copbio.2013.08.015
  8. Erickson KA, Bhansali S. Mycoplasma contamination in cell cultures: a survey of incidence and approaches to prevention. Journal of the Association for Laboratory Automation. 2012;17(5):346–354.doi:10.1177/2211068212456089
  9. van Duinen V, et al. Microfluidic 3D cell culture: from tools to tissue models. Current Opinion in Biotechnology. 2015;35:118–126.doi:10.1016/j.copbio.2015.05.002
  10. Warburg O. On the origin of cancer cells. Science. 1956;123(3191):309–314.doi:10.1126/science.123.3191.309

Satisfaction
Quality Rating
Value Rating
Style Rating
X