[Part Only] Extra paper roll for SmartDrop internal printer, Pk 3 (SmartDrop)

Product#: BM-NS1000-PA
$45.45
Availability:
Ships in 48 hours

This product is ONLY an ACCESSORY PART of the machine.  This accessory part is SOLD SEPARATELY from the main machine.

[Part Only] Extra paper roll for SmartDrop internal printer, Pk 3 (SmartDrop)


Cat.No.: BM-NS1000-PA

*This item is only for the SmartDrop L, X, and XF series


DNA/RNA/protein quantification and purity
Nano Spectrophotometer for SmartDrop L, X, and XF series

 
  • Extra paper rolls for SmartDrop internal printer
  • pack: 3


*** Ask for below-listed kits(100 assays). we are ready to ship.
  High Sensitivity DNA Quantification Kit, 100 assays    BM-F1000-HS-100
  Broad Range dsDNA Quantification Kit, 100 assays  BM-F1000-BR-100
 
 
The Accuris SmartDrop™ series of nano spectrophotometers provides quick and easy quantification of small samples. Utilizing a small sample volume eliminates the need for dilutions, providing more accurate results.

A full color, 7” touchscreen with icon-driven menus and preprogrammed protocols gets users up and running quickly. No external computer is required. Each unit features a quartz pedestal onto which a drop of sample is placed. The arm is lowered and the drop is stretched into a liquid column of specificed length for spectral analysis. DNA, RNA and protein concentrations and purity numbers are displayed in a matter of seconds. The resulting data can be printed, saved in the SmartDrop’s onboard memory or exported via USB as an Excel file. All SmartDrop models include an integrated printer. For OD600 readings, each model includes a cuvette port and two optical glass cuvettes. Three SmartDrop models are available to meet a range of applications and budgets.
 


The Accuris SmartDrop™ series of nano spectrophotometers provides quick and easy quantification of small samples. Utilizing a small sample volume eliminates the need for dilutions, providing more accurate results. A full color, 7” touchscreen with icon-driven menus and preprogrammed protocols gets users up and running quickly. No external computer is required. Each unit features a quartz pedestal onto which a drop of sample is placed. The arm is lowered and the drop is stretched into a liquid column of specificed length for spectral analysis. DNA, RNA and protein concentrations and purity numbers are displayed in a matter of seconds. The resulting data can be printed, saved in the SmartDrop’s onboard memory or exported via USB as an Excel file. All SmartDrop models include an integrated printer. For OD600 readings, each model includes a cuvette port and two optical glass cuvettes. Three SmartDrop models are available to meet a range of applications and budgets.

SmartDrop L is the affordable choice for laboratories needing to determine nucleic acid and protein concentrations and purity of samples. The LED light source and silicon photocell sensor provide readings at 260 and 280nm. Samples from 1.0 to 2.0µl are loaded directly on the pedestal. Results are provided in about 5 seconds. The software automatically calculates and displays 260/280 ratios

 

* Other types and Accessaries
 
 Cat. No.  Description  more info. 
 BM-NS1000  SmartDrop™ L Nano Spectrophotometer, 115V
 BM-NS1010  SmartDrop™ X Nano Spectrophotometer, 115V
 BM-NS1020  SmartDrop™ XF Nano Spectrophotometer, 115V

 BM-F1001-T

 (BM-F1000-HS-100)
 (BM-F1000-BR-100)
 
0.5mL Fluorescence Detection Tubes, pack of 250

 * Ask for High Sensitivity DNA Quantification Kit  /or
 Broad Range dsDNA Quantification Kit  (available now)
 BM-NS1000-C  Additional Standard-Size Cuvettes, pack of 2
 BM-NS1000-PA  Extra paper roll for SmartDrop internal printer, Pk 3
 


Specifications

Model SmartDrop L (NS1000) SmartDrop X (NS1010) SmartDrop XF (NS1020)
Display 7-inch touch screen 7-inch touch screen 7-inch touch screen
Minimum sample size 1.0µl – 2.0µl 0.5µl – 2.0µl 0.5µl – 2.0µl
Path length 0.5mm 0.2mm, 1.0mm 0.05mm, 0.2mm, 1.0mm
Light source UV LED Xenon Flash Lamp Xenon Flash Lamp
Detector UV Silicon Photocell 2048 Element Linear Silicon CCD Array 2048 Element Linear Silicon CCD Array
Wavelength 260, 280, & 600nm 200 – 800nm (1nm steps) 200 – 800nm (1nm steps)
Absorbance range 0.2 – 50 A (10mm equivalent) 0.04 – 90 A (10mm equivalent) 0.04 – 300 A (10mm equivalent)
Absorbance precision 0.005 A 0.003 A 0.003 A
Lower limit of detection dsDNA: 10ng/µl dsDNA: 2ng/µl; BSA: 0.1mg/ml dsDNA: 2ng/µl ; BSA: 0.1mg/ml
Upper limit of detection dsDNA: 2,500ng/µl dsDNA: 4,500ng/µl; BSA: 135mg/ml dsDNA: 15,000ng/µl; BSA: 360mg/ml
Detection time < 6 seconds < 5 seconds < 6 seconds
Communication ports USB for data export USB for data export USB for data export
Voltage input DC 24V, 2A DC 24V, 2A DC 24V, 2A
Power 25W 25W 25W
Dimensions (WxDxH) 20.8 x 8.0 x 18.6 cm / 8.2 x 11.0 x 7.3 in. 20.8 x 8.0 x 18.6 cm / 8.2 x 11.0 x 7.3 in. 20.8 x 8.0 x 18.6 cm / 8.2 x 11.0 x 7.3 in.
Weight 3.6 kg / 7.9 lbs 2.8 kg / 6.2 lbs 3.6 kg / 7.9 lbs
Cuvette OD600 detection      
Absorbance range 0.0 – 4.0 A 0.0 – 4.0 A 0.0 – 4.0 A
Absorbance stability [0,3) ≤ 0.5%, [3,4) ≤ 2% [0,3) ≤ 0.5%, [3,4) ≤ 2% [0,3) ≤ 0.5%, [3,4) ≤ 2%
Absorbance repeatibility [0,3) ≤ 0.5%, [3,4) ≤ 2% [0,3) ≤ 0.5%, [3,4) ≤ 2% [0,3) ≤ 0.5%, [3,4) ≤ 2%
Absorbance precision [0,2) ≤ 0.005 A, [2,3) ≤ 1%, [3,4) ≤ 2% [0,2) ≤ 0.005 A, [2,3) ≤ 1%, [3,4) ≤ 2% [0,2) ≤ 0.005 A, [2,3) ≤ 1%, [3,4) ≤ 2%
Fluorescence detection      
Excitation/Emission N/A N/A 460 ± 20nm / 525-570nm
Sensitivity N/A N/A dsDNA: 0.5pg/µl
Linearity N/A N/A R² ≥ 0.995
Repeatibility N/A N/A ≤ 1.5%
Stability N/A N/A ≤ 1.5%







 

Satisfaction
Quality Rating
Value Rating
Style Rating
X