FluxMPS™ Minimum Essential Medium (MEM), High Glucose w/o L-Glutamine, Phenol Red: 1X Liquid

Product#: DCP-MEMG-QRN1X
$34.10
DCP-MEMG-QRN1X
Availability:
Ships in 1-2 Weeks

warning For Research Use Only (RUO). Not intended for clinical, diagnostic, or therapeutic use in humans.
ISO 13485 Certified Manufacturing

FluxMPS™ Minimum Essential Medium (MEM), High Glucose w/o L-Glutamine, Phenol Red: 1X Liquid

Contains Sodium Bicarbonate Contains Calcium Contains Magnesium Contains Glucose Contains Sodium Pyruvate Without L-Glutamine Without Phenol Red Without HEPES

FluxMPS™ Minimum Essential Medium (MEM), High Glucose w/o L-Glutamine, Phenol Red: 1X Liquid is a Microfluidics Suitable, quadruple-stage ultra-filtered (0.1 µm ×2 + 0.04 µm ×2) 1X liquid cell culture medium engineered for microfluidic channels, organ-on-a-chip (OoC), and microphysiological system (MPS) applications. The 0.04 µm final cut-off is five times finer than the 0.22 µm membranes used in conventional sterile filtration, keeping microchannels clear of sub-visible particulates and mycoplasma-sized debris.

  • High-glucose (4.5 g/L) MEM base formulated without L-Glutamine or Phenol Red for full control over glutamine source and optical readouts
  • Contains 110 mg/L sodium pyruvate as a supplemental carbon/energy source alongside glucose
  • Quadruple-stage filtration train (0.1 µm ×2 + 0.04 µm ×2) reaching a validated 0.04 µm final pore size
  • Endotoxin release specification < 0.05 EU/mL (LAL, USP <85>), controlled and tested per manufacturing batch
  • Bicarbonate-buffered (2200 mg/L NaHCO3); approximately 5–6% CO₂ atmosphere required to maintain physiological pH
  • Manufactured under an ISO 13485:2016 quality management system, with final QC, fill and finish at Diagnocine, Totowa, NJ
  • Custom formulations available — pH, glucose, salts, HEPES, and nutrient composition on request at support@diagnocine.com
DCP-MEMG-QRN1X | Cell Culture Media
UNSPSC: 41116155 | Commodity: Molecular biology and cell culture growth media | (UNv260801)
Minimum Essential Medium (MEM), High Glucose w/o L-Glutamine, Phenol Red: 1X Liquid
  • Glucose4500 mg/L (4.5 g/L)
  • L-GlutamineNot added — supplement as needed
  • Sodium Pyruvate110 mg/L
  • pH (USP <791>)7.4
  • Osmolality (USP <785>)See CoA
  • Endotoxin (USP <85>)< 0.05 EU/mL
  • Filtration0.1 µm ×2 + 0.04 µm ×2 (Quadruple-stage)
  • Storage2–8°C, protect from light
  • Shelf Life12 months from date of manufacture, unopened
  • ShippingCold pack
ISO 13485:2016 USP <85> <785> <788> RUO
Why FluxMPS™

Engineered where standard media fails

Conventional 0.22 µm-filtered media carry mycoplasma-sized particulates (0.2–0.3 µm), subvisible debris, and inconsistent endotoxin loads that accumulate inside microchannels — corrupting biosensor readings and shortening device lifetimes. FluxMPS™ is built to avoid these failure modes.

filter_alt

Microchannel-safe purity

0.04 µm final filter retains particles down to sub-mycoplasma size; USP <788> Method 1 (light obscuration) particulate compliance is confirmed per production lot.

target

High-glucose metabolic support

4.5 g/L glucose plus 110 mg/L sodium pyruvate support high-energy-demand cell types including HeLa, MCF-7, fibroblasts, and iPSC-derived models in perfusion devices.

water_drop

Ultrapure-grade water

Prepared with Type 1 water (18.2 MΩ·cm, ASTM D1193 / ISO 3696), formulated under trace-metal and organic-carbon (TOC) controlled conditions.

visibility

Low background for imaging

Low particulate baseline supports confocal microscopy, live-cell biosensors, and TEER measurements. Riboflavin is present in this formulation at 0.100 mg/L; verify autofluorescence tolerance for your specific optical assay.

science

Rich, stable nutrient profile

A complete essential amino acid profile plus micro-batch precision manufacturing ensures consistent nutrient delivery lot to lot.

tune

Customization on demand

pH, glucose, salts, HEPES, and full nutrient composition available on request. Contact support@diagnocine.com.

Purity Architecture

Quadruple-stage filtration system

FluxMPS™ Minimum Essential Medium (MEM), High Glucose w/o L-Glutamine, Phenol Red: 1X Liquid is processed through a four-pass filtration train — two dedicated prefilter + final-filter pairs — reaching a 0.04 µm final cut-off, addressing mycoplasma-sized and subvisible particulates that single-pass 0.22 µm filtration cannot remove.

  1. 1

    0.1 µm Prefiltration I

    Removes large particulates, cell debris and protein aggregates; protects the first 0.04 µm cartridge.

  2. 2

    0.04 µm Final filtration I

    First 0.04 µm pass; retains sub-micron particulates and microaggregates that pass through a 0.22 µm membrane.

  3. 3

    0.1 µm Prefiltration II

    Second, dedicated prefilter protecting the second 0.04 µm cartridge — full redundancy, not a polishing pass on Stage 2 effluent.

  4. 4

    0.04 µm Final filtration II — Polish

    Ultimate polishing filter; aseptic fill and finish performed in a validated ISO Class 5 laminar-flow workstation.

Purity architecture vs. conventional media

A quadruple-stage train (0.1 µm ×2 + 0.04 µm ×2) reaches a 0.04 µm final cut-off, five times finer than the 0.22 µm membranes used for conventional sterile filtration, with USP <788> Method 1 particulate compliance confirmed on every production lot.

4
Sequential filtration passes (0.1 µm ×2 + 0.04 µm ×2)
0.04
µm final pore size — 5.5× finer than a 0.22 µm membrane
Sterility assurance: Every lot undergoes 14-day USP <71> sterility testing. Mycoplasma is controlled via 0.1 µm mycoplasma-retentive filtration (0.2–0.3 µm organism size range); this is a filtration-based risk-mitigation step, not a per-lot mycoplasma assay. No bacterial or fungal growth observed.
Grade: This product is Microfluidics Suitable, filtered to a 0.04 µm final cut-off. It is not an MPS Grade product — that designation is reserved for the 0.01 µm ultra nano-filtered line, which adds 0.02 µm and 0.01 µm stages after the 0.04 µm polish. For applications requiring the 0.01 µm cut-off, contact support@diagnocine.com.
FluxMPS Minimum Essential Medium (MEM) High Glucose w/o L-Glutamine Phenol Red 1X Liquid (DCP-MEMG-QRN1X) Quadruple-stage filtration system: 0.1 micron Prefiltration I, 0.04 micron Final filtration I, 0.1 micron Prefiltration II, 0.04 micron Final filtration II for organ-on-a-chip and microfluidic applications by Diagnocine
Figure 1. FluxMPS™ Quadruple-stage filtration architecture (0.1 µm ×2 + 0.04 µm ×2) delivering microfluidics-suitable purity for MPS and OoC applications.
© Diagnocine® — DCP-MEMG-QRN1X
Applications

Designed for next-generation cell culture platforms

FluxMPS™ Minimum Essential Medium (MEM), High Glucose w/o L-Glutamine, Phenol Red: 1X Liquid is suited to organ-on-a-chip, cancer biology, metabolic research, live-cell imaging, and primary/stem-cell models where particulate load and endotoxin variability are unacceptable.

Automated Bioreactors & Robotics

Next-Generation System Uptime

An optional 0.01 µm (10 nm) ultra nano-filtered MPS Grade variant is available for automated bioreactor and robotic perfusion systems requiring the finest available particulate exclusion.

  • Total Particulate Exclusion: 10 nm filtration for nanoscale valve and sensor protection
  • Valve & Sensor Protection: reduces particulate-induced blockage risk in precision fluidic systems
  • Extended Perfusion Stability: supports flow-rate consistency across multi-week automated runs

Inquiry Required: Contact support@diagnocine.com to request the MPS Grade 0.01 µm variant.

Microfluidics

Micro Physiological System (MPS) & Chip

Quadruple-stage filtered formulation helps prevent microchannel clogging and supports laminar flow integrity across complex chip geometries.

OoCToCBoCLoCMPS
Cancer Biology

Warburg Effect & Metabolic Research

High-glucose base supports Warburg effect studies and glucose uptake assays in cancer cell lines.

MCF-7MDA-MB-231HeLaHT-1080
Stem Cell Biology

iPSC-Derived Models

Ultra-filtered formulation supports sensitive iPSC differentiation protocols where particulate and endotoxin variability can cause off-target effects.

iPSC-NeuronsiPSC-CMiPSC-Hep
Vascular Biology

Endothelial & Primary Cells

Microchannel-safe purity supports endothelial barrier integrity and TEER measurements in perfusion models.

HUVECsBHK-21Primary fibroblasts
Metabolomics

Metabolic Flux Analysis

High-glucose base enables 13C isotope tracing and glycolytic flux experiments. Not compatible with Agilent Seahorse XF assays, which require bicarbonate-free, phenol red-free medium.

13C tracingNMR metabolomics
Live-Cell Imaging

Microscopy & Optical Sensing

Low particulate baseline suits high-content confocal imaging and optical biosensor integration; note this formulation contains riboflavin (0.100 mg/L).

ConfocalBiosensorsTEER
Technical Specifications

Lot-release quality parameters

Every production lot of FluxMPS™ Minimum Essential Medium (MEM), High Glucose w/o L-Glutamine, Phenol Red: 1X Liquid undergoes the quality-release battery below before shipment.

Physical & Chemical Parameters
Parameter Specification
Formulation Contains Sodium Bicarbonate, Calcium, Magnesium, Glucose, Sodium Pyruvate; without L-Glutamine, Phenol Red, HEPES
Appearance Pale yellow, clear solution (phenol red-free)
pH USP <791> 7.4
Osmolality USP <785> See CoA
Glucose 4500 mg/L (4.5 g/L)
L-Glutamine Not added — supplement as needed
Sodium Pyruvate 110 mg/L
Phenol Red Not added
Sterility, Purity & Safety Parameters
Parameter Specification
Endotoxin USP <85> BET < 0.05 EU/mL (batch release specification — see §Manufacturing & Compliance)
Sterility USP <71> No growth after 14 days
Mycoplasma 0.1 µm mycoplasma-retentive filtration (not tested per lot)
Particulate ≥10 µm USP <788> Method 1 Compliant
Particulate ≥25 µm USP <788> Method 1 Compliant
Water purity Ultrapure Type 1 water, 18.2 MΩ·cm (ASTM D1193 / ISO 3696)
Manufacturing std. ISO 13485 ISO 13485:2016
Fill environment ISO Class 5 (Class 100)
Storage, Handling & Logistics
Parameter Specification
Storage temperature 2–8°C, protected from light
Freeze-thaw Not recommended
Shelf life 12 months from date of manufacture, unopened
Shipping condition Cold pack
CO₂ requirement Approximately 5–6% CO₂ (bicarbonate-buffered, 2200 mg/L NaHCO3; verify with in-house calibration)
Available pack sizes 500 mL, 1000 mL
Raw Materials & Regulatory Traceability
Parameter Specification
Raw material grade Cell culture / reagent grade
Traceability Full lot documentation, CoA available
Manufacturing QMS ISO 13485:2016 certified
UNSPSC 41116155 — Molecular biology and cell culture growth media (UNv260801)
Regulatory alignment 21 CFR Part 820 (QMSR) aligned
Production method Micro-batch precision manufacturing
Intended use For Research Use Only (RUO)
Formulation

Full composition (mg/L)

Complete formulation — 28 components across 4 formulation categories (Inorganic Salts, Amino Acids, Vitamins, Others), with CAS numbers reproduced from manufacturer specification. Custom compositions available on request.

Component CAS Number mg/L
INORGANIC SALTS
Calcium chloride dihydrate 10035-04-8 265.000
Magnesium sulfate anhydrous 7487-88-9 97.720
Potassium chloride 7447-40-7 400.000
Sodium bicarbonate 144-55-8 2200.000
Sodium chloride 7647-14-5 6800.00
Sodium phosphate dibasic anhydrous 7558-79-4 122.000
Component CAS Number mg/L
AMINO ACIDS
L-Arginine hydrochloride 1119-34-2 126.000
L-Cystine dihydrochloride 30189-89-0 31.300
L-Histidine hydrochloride monohydrate 5934-29-2 42.000
L-Isoleucine 73-32-5 52.000
L-Leucine 61-90-5 52.000
L-Lysine hydrochloride 657-27-2 72.500
L-Methionine 63-68-3 15.000
L-Phenylalanine 63-91-2 32.000
L-Threonine 72-19-5 48.000
L-Tryptophan 73-22-3 10.000
L-Tyrosine disodium salt 69847-45-6 51.900
L-Valine 72-18-4 46.000
Component CAS Number mg/L
VITAMINS
Choline chloride 67-48-1 1.000
D-Ca-Pantothenate 137-08-6 1.000
Folic acid 59-30-3 1.000
Niacinamide 98-92-0 1.000
Pyridoxine hydrochloride 58-56-0 1.000
Riboflavin 83-88-5 0.100
Thiamine hydrochloride 67-03-8 1.000
OTHERS
D-Glucose 50-99-7 4500.000
Sodium Pyruvate 113-24-6 110.000
i-Inositol 87-89-8 2.000
Customization: pH, glucose, salt balance, HEPES, and full nutrient profile available on request. Contact support@diagnocine.com.
Quality Assurance

ISO 13485:2016 manufacturing & compliance

Manufactured under ISO 13485:2016 QMS with final packaging, testing, and customization at Diagnocine, Totowa, New Jersey, USA.

verified

ISO 13485:2016 QMS

Full quality management system certification covering manufacturing, testing, and release for every production lot.

water_drop

Ultrapure Type 1 Water

All media prepared with 18.2 MΩ·cm resistivity water (ASTM D1193 / ISO 3696), under trace-metal and TOC-controlled conditions.

biotech

ISO Class 5 Fill & Finish

Aseptic filling in a validated ISO Class 5 laminar-flow workstation; 21 CFR Part 820 (QMSR) aligned.

assignment

Micro-Batch Precision

Small-batch manufacturing supports lot-to-lot nutrient consistency for reproducible perfusion studies.

Endotoxin — USP <85> BET

LAL assay on every manufacturing batch. Release specification: < 0.05 EU/mL.

Particulate — USP <788> Method 1

Light obscuration particle count confirms ≥10 µm and ≥25 µm compliance per lot.

Osmolality — USP <785>

Freezing-point osmometry per USP <785>. Result: See CoA.

Documentation — CoA & Full Lot Records

Certificate of Analysis with full QC panel, traceability, and release signatures for every lot.

Batch-level quality control. Endotoxin is controlled per manufacturing batch rather than per unit. Every batch is tested before release and must meet the release specification:
  • Endotoxin — LAL assay, USP <85> Bacterial Endotoxins Test; assay sensitivity 0.005 EU/mL; release specification < 0.05 EU/mL
  • pH, osmolality, conductivity, appearance and clarity
  • Sterility
A Certificate of Analysis is available on request via support@diagnocine.com.
Product Comparison

How DCP-MEMG-QRN1X (FluxMPS™) compares

Side-by-side comparison against conventional 0.22 µm-filtered MEM High Glucose alternatives, and published supplier endotoxin specifications.

Parameter DCP-MEMG-QRN1X (FluxMPS™) Conventional MEM High Glucose (0.22 µm) Standard MEM High Glucose alternative
Grade Microfluidics Suitable Standard Standard
Base Formulation MEM High Glucose, w/o L-Glutamine, w/o Phenol Red, bicarbonate-buffered MEM High Glucose Standard MEM High Glucose Equivalent
Final filtration pore size 0.04 µm 0.22 µm 0.22 µm
Number of filtration stages 4 stages 1 stage 1–2 stages
Mycoplasma barrier filtration check_circle cancel cancel
Endotoxin (release specification) FluxMPS™ — < 0.05 EU/mL Corning classical liquid media — < 0.25 EU/mL
Sigma-Aldrich DMEM complete medium — ≤ 2 EU/mL
Gibco classical DMEM — Not specified (recorded per lot)
USP particulate compliance check_circle USP <788> Method 1 cancel cancel
Water quality Ultrapure Type 1 (18.2 MΩ·cm) Purified water Purified water
Manufacturing QMS ISO 13485:2016 Variable Variable
Microfluidic channel compatibility check_circle Validated cancel Risk of clogging cancel Risk of clogging
Custom formulation check_circle On request cancel Limited

Comparison figures from published supplier specifications, accessed 2026-09-02. Suppliers that publish no numeric endotoxin specification are shown as "Not specified".

FAQ

Frequently asked questions

Common questions about FluxMPS™ Minimum Essential Medium (MEM), High Glucose w/o L-Glutamine, Phenol Red: 1X Liquid and Microfluidics Suitable cell culture media.

Yes. DCP-MEMG-QRN1X is processed through our Quadruple-stage filtration train (0.1 µm ×2 + 0.04 µm ×2), reaching a 0.04 µm final cut-off that helps prevent microchannel clogging in OoC and MPS devices. It is a Microfluidics Suitable product, not an MPS Grade (0.01 µm) product.
Standard 0.22 µm filtration does not retain mycoplasma-sized organisms (0.2–0.3 µm) or fine subvisible particulates. FluxMPS™ uses four sequential passes (0.1 µm ×2 + 0.04 µm ×2) reaching a 0.04 µm final cut-off — five times finer than a 0.22 µm membrane — with USP <788> Method 1 compliance confirmed per lot.
L-Glutamine is omitted because it degrades in liquid storage; add it fresh (or as a stabilized dipeptide) at the concentration your protocol requires. Phenol Red is omitted for optical assays sensitive to absorbance/fluorescence background. Contact support@diagnocine.com for a custom formulation with either component included.
Yes. This formulation is bicarbonate-buffered (2200 mg/L NaHCO3) and requires approximately 5–6% CO₂ to maintain physiological pH; verify the exact set point against your incubator and open/closed culture format.
Yes. FluxMPS™ Minimum Essential Medium (MEM), High Glucose w/o L-Glutamine, Phenol Red: 1X Liquid can be supplemented with FBS (5–20%), growth factors, antibiotics, or other additives per standard practice. Filter serum-containing or protein-containing supplements through a 0.2 µm low-protein-binding PES or PVDF membrane before addition; a 0.04 µm membrane is not appropriate for serum supplementation and will strip lipoproteins and clog rapidly. Add supplements immediately before use.
Endotoxin is controlled per manufacturing batch, not per unit. Every batch is tested by LAL assay per USP <85> BET (assay sensitivity 0.005 EU/mL) and must meet the release specification of < 0.05 EU/mL before shipment. A Certificate of Analysis with the batch result is available from support@diagnocine.com.
Yes. A batch-specific CoA is available for every shipment and includes: appearance, pH (USP <791>), osmolality (USP <785>), endotoxin (USP <85> BET), sterility (USP <71>), particulate matter (USP <788> Method 1), raw material traceability, manufacturing date, and authorized release signatures. Request via support@diagnocine.com.
Scientific References

Supporting literature

Peer-reviewed publications supporting ultra-filtered, Microfluidics Suitable media and microfluidic cell culture applications.

  1. Huh D et al. (2010). Reconstituting organ-level lung functions on a chip. Science, 328(5986), 1662–1668. doi:10.1126/science.1188302
  2. Bhatia SN & Ingber DE (2014). Microfluidic organs-on-chips. Nature Biotechnology, 32(8), 760–772. doi:10.1038/nbt.2989
  3. Eagle H (1959). Amino acid metabolism in mammalian cell cultures. Science, 130(3373), 432–437. doi:10.1126/science.130.3373.432
  4. Warburg O (1956). On the origin of cancer cells. Science, 123(3191), 309–314. doi:10.1126/science.123.3191.309
  5. Bhattacharya S et al. (2018). Challenges in maintaining cell viability during microfluidic experiments. Electrophoresis, 39(7), 997–1006. doi:10.1002/elps.201700375
  6. Zhang YS et al. (2017). Multisensor-integrated organs-on-chips for automated in situ monitoring. PNAS, 114(12), E2293–E2302. doi:10.1073/pnas.1612906114
  7. Vernetti L et al. (2017). Functional coupling of human microphysiology systems. Scientific Reports, 7, 42296. doi:10.1038/srep42296
  8. Esch EW et al. (2015). Organs-on-chips at the frontiers of drug discovery. Nature Reviews Drug Discovery, 14(4), 248–260. doi:10.1038/nrd4539
  9. Zheng F et al. (2021). Organ-on-a-chip systems: microengineering to biomimic living systems. Small, 17(7), 2004175. doi:10.1002/smll.202004175

Satisfaction
Quality Rating
Value Rating
Style Rating
X