FluxMPS™ Minimum Essential Medium (MEM), High Glucose, NEAA & 25mM HEPES w/o Sodium Bicarbonate: 1X Liquid

Product#: DCP-MEMGH-B1X
$49.50
DCP-MEMGH-B1X
Availability:
Ships in 1-2 Weeks

warning For Research Use Only (RUO). Not intended for clinical, diagnostic, or therapeutic use in humans.
ISO 13485 Certified Manufacturing

FluxMPS™ Minimum Essential Medium (MEM), High Glucose, NEAA & 25mM HEPES w/o Sodium Bicarbonate: 1X Liquid

Contains L-Glutamine Contains Phenol Red Contains HEPES Contains Calcium Contains Magnesium Contains Glucose Contains Sodium Pyruvate Without Sodium Bicarbonate

FluxMPS™ Minimum Essential Medium (MEM), High Glucose, NEAA & 25mM HEPES w/o Sodium Bicarbonate: 1X Liquid is a Microfluidics Suitable, quadruple-stage ultra-filtered (0.1 µm ×2 + 0.04 µm ×2) 1X liquid cell culture medium engineered for organ-on-a-chip (OoC), tissue-on-a-chip (ToC), and microphysiological system (MPS) applications.[1]A quadruple-stage train (0.1 µm ×2 + 0.04 µm ×2) reaches a 0.04 µm final cut-off, five times finer than the 0.22 µm membranes used for conventional sterile filtration.

  • High glucose (4.5 g/L) formulation with Non-Essential Amino Acids (NEAA) — supports high-energy-demand cell types
  • Quadruple-stage filtration: 0.1 µm (Prefiltration I & II) + 0.04 µm (Final filtration I & II — Polish)
  • Endotoxin release specification: < 0.05 EU/mL (USP <85> BET, LAL assay)
  • pH 7.4 (USP <791>); osmolality reported per Certificate of Analysis
  • HEPES-buffered (25 mM), bicarbonate-free formulation — reduced CO₂ dependence
  • ISO Class 5 aseptic fill & finish; ISO 13485:2016 QMS manufacturing
  • Custom formulations available — pH, glucose, salts, HEPES, nutrients on request
DCP-MEMGH-B1X | Cell Culture Media
UNSPSC: 41116155 · Commodity: Molecular biology and cell culture growth media · (UNv260801)
Minimum Essential Medium (MEM), High Glucose, NEAA & 25mM HEPES w/o Sodium Bicarbonate: 1X Liquid
  • Glucose4500 mg/L (4.5 g/L)
  • L-Glutamine292 mg/L
  • Sodium Pyruvate110 mg/L
  • HEPES5958 mg/L (25 mM)
  • NEAAIncluded
  • pH (USP <791>)7.4
  • Osmolality (USP <785>)See CoA
  • Endotoxin (USP <85>)< 0.05 EU/mL
  • Filtration0.1 µm ×2 + 0.04 µm ×2 (Quadruple-stage)
  • Shelf Life12 months from date of manufacture, unopened
ISO 13485:2016 USP <85> <785> <788> RUO
Why FluxMPS™

Engineered where standard media fails

Conventional 0.22 µm-filtered media carry mycoplasma-sized particulates (0.2–0.3 µm), subvisible debris, and endotoxin variability that accumulate inside microchannels — corrupting biosensor readings and shortening device lifetimes. FluxMPS™ is built to reduce these failure modes at the filtration stage.[2]

filter_alt

Microchannel-safe purity

0.04 µm final filter retains particles down to sub-mycoplasma size; USP <788> Method 1 (light obscuration) particulate compliance verified per lot.

target

High-glucose metabolic support

4.5 g/L glucose supports high-energy-demand cell types including HeLa, MCF-7, fibroblasts, and iPSC-derived models in perfusion devices.

water_drop

Ultrapure-grade water

Prepared with Type 1 water (18.2 MΩ·cm) for tight trace-metal and organic-carbon (TOC) control, supporting a consistent, reproducible cell culture base.

visibility

Low background for imaging

Quadruple-stage filtration minimizes particulate background, supporting a cleaner baseline for confocal microscopy, live-cell biosensors, and TEER measurements. This formulation contains phenol red; a phenol red-free variant is available on request for fluorescence-sensitive assays.

science

Rich, stable nutrient profile

NEAA-supplemented formulation plus micro-batch precision ensures comprehensive amino acid coverage for demanding cell culture models.

tune

Customization on demand

pH, glucose, salts, HEPES, and full nutrient composition available on request. Contact support@diagnocine.com.

Purity Architecture

Quadruple-stage filtration system

FluxMPS™ Minimum Essential Medium (MEM), High Glucose, NEAA & 25mM HEPES w/o Sodium Bicarbonate: 1X Liquid is processed through a four-stage filtration train — two dedicated prefilter/final-filter pairs — reaching a 0.04 µm final pore size, addressing mycoplasma-sized particulates and subvisible particles that 0.22 µm filtration does not retain.

  1. 1

    0.1 µm Prefiltration I

    Removes large particulates, cell debris and protein aggregates; protects the first 0.04 µm final filter cartridge.

  2. 2

    0.04 µm Final filtration I

    First 0.04 µm pass; retains sub-micron particulates and microaggregates that pass through a 0.22 µm filter, including mycoplasma-sized particles (0.2–0.3 µm).

  3. 3

    0.1 µm Prefiltration II

    Second dedicated prefilter, protecting the second 0.04 µm final filter cartridge from particulate loading.

  4. 4

    0.04 µm Final filtration II — Polish

    Ultimate polishing filter; aseptic fill and finish performed under validated ISO Class 5 laminar-flow conditions.

Performance vs. conventional media

Four sequential stages reaching 0.04 µm deliver approximately 5× cleaner media by particulate count compared to single-pass 0.22 µm filtration, with USP <788> compliance verified on every production lot.

5×
 
0.04
µm final filter pore size — sub-mycoplasma polishing
Sterility assurance: Every lot undergoes 14-day USP <71> sterility testing. Mycoplasma risk is controlled by 0.1 µm mycoplasma-retentive filtration; lots are not individually tested to USP <63>. No bacterial or fungal growth was observed in sterility testing.
Grade: This product is Microfluidics Suitable, filtered to a 0.04 µm final cut-off. It is not an MPS Grade product — that designation is reserved for the 0.01 µm ultra nano-filtered line, which adds 0.02 µm and 0.01 µm stages after the 0.04 µm polish. For applications requiring the 0.01 µm cut-off, contact support@diagnocine.com.
FluxMPS™ Minimum Essential Medium (MEM), High Glucose, NEAA & 25mM HEPES w/o Sodium Bicarbonate 1X Liquid (DCP-MEMGH-B1X) Quadruple-stage filtration system: 0.1 μm Prefiltration I & II, 0.04 μm Final filtration I & II for organ-on-a-chip and microfluidic cell culture applications by Diagnocine
Figure 1. FluxMPS™ Quadruple-stage filtration architecture (0.1 µm ×2 + 0.04 µm ×2) delivering sub-mycoplasma purity for MPS and OoC applications.
© Diagnocine® — DCP-MEMGH-B1X
Applications

Designed for next-generation cell culture platforms

FluxMPS™ Minimum Essential Medium (MEM), High Glucose, NEAA & 25mM HEPES w/o Sodium Bicarbonate: 1X Liquid is suited for organ-on-a-chip, cancer biology, metabolic research, live-cell imaging, and primary/stem-cell models where particulate contamination and endotoxin variation are unacceptable.

Automated Bioreactors & Robotics

Next-Generation System Uptime

An optional 0.01 µm (10 nm) ultra nano-filtered MPS Grade variant — a distinct, six-stage cascade beyond this Microfluidics Suitable product — is available for automated bioreactor and robotic perfusion systems requiring the ultimate particulate exclusion.

  • Total Particulate Exclusion: 10 nm filtration for nanoscale valve and sensor protection
  • Valve & Sensor Protection: prevents particulate-induced blockage in precision fluidic systems
  • Extended Perfusion Stability: maintains flow rate consistency across multi-week automated runs

Inquiry Required: Contact support@diagnocine.com to request the 0.01 µm MPS Grade variant.

Microfluidics

Micro Physiological System (MPS) & Chip

Ultra-filtered formulation reduces the risk of microchannel clogging and helps maintain laminar flow integrity across complex chip geometries.

OoCToCBoCLoCMPS
Cancer Biology

Warburg Effect & Metabolic Research

High-glucose base supports Warburg effect studies and glucose uptake assays in cancer cell lines.[4]

MCF-7MDA-MB-231HeLaHT-1080
Stem Cell Biology

iPSC-Derived Models

Ultrapure formulation supports sensitive iPSC differentiation protocols where endotoxin variability causes off-target effects.

iPSC-NeuronsiPSC-CMiPSC-Hep
Vascular Biology

Endothelial & Primary Cells

Microchannel-safe purity supports endothelial barrier integrity and TEER measurements in perfusion models.

HUVECsBHK-21Primary fibroblasts
Metabolomics

Metabolic Flux Analysis

High-glucose base enables ¹³C isotope tracing and glycolytic flux experiments.[3] Not compatible with Agilent Seahorse XF assays, which require bicarbonate-free, phenol red-free medium; this formulation contains phenol red.

13C tracingNMR metabolomics
Live-Cell Imaging

Microscopy & Optical Sensing

Quadruple-stage filtration minimizes particulate background for high-content confocal imaging and optical biosensor integration. Contains phenol red; consider a phenol red-free formulation for fluorescence-sensitive assays.

ConfocalBiosensorsTEER
Technical Specifications

Lot-release quality parameters

Every production lot of FluxMPS™ Minimum Essential Medium (MEM), High Glucose, NEAA & 25mM HEPES w/o Sodium Bicarbonate: 1X Liquid undergoes the complete quality-release battery below before shipment.

Physical & Chemical Parameters
Parameter Specification
Formulation L-Glutamine, Phenol Red, HEPES, Calcium, Magnesium, Glucose, Sodium Pyruvate; without Sodium Bicarbonate
Appearance Red-orange colored, clear solution
pH USP <791> 7.4
Osmolality USP <785> See CoA
Glucose 4500 mg/L (4.5 g/L)
L-Glutamine 292 mg/L
Sodium Pyruvate 110 mg/L
Phenol Red 11 mg/L (present)
Sterility, Purity & Safety Parameters
Parameter Specification
Endotoxin USP <85> BET < 0.05 EU/mL
Sterility USP <71> No growth after 14 days
Mycoplasma 0.1 µm mycoplasma-retentive filtration (not tested per lot)
Particulate ≥10 µm USP <788> Method 1 Compliant
Particulate ≥25 µm USP <788> Method 1 Compliant
Water purity Ultrapure Type 1 water (18.2 MΩ·cm)
Manufacturing std. ISO 13485 ISO 13485:2016
Fill environment ISO Class 5 (Class 100)
Storage, Handling & Logistics
Parameter Specification
Storage temperature 2–8°C, protected from light
Freeze-thaw Not recommended
Shelf life 12 months from date of manufacture, unopened
Shipping condition Cold pack
CO₂ requirement HEPES-buffered; reduced CO₂ dependence (validate per cell line)
Raw Materials & Regulatory Traceability
Parameter Specification
Raw material grade Cell culture / reagent grade
Traceability Full lot documentation, CoA available
Manufacturing QMS ISO 13485:2016 certified
UNSPSC 41116155 — Molecular biology and cell culture growth media (UNv260801)
Regulatory alignment 21 CFR Part 820 (QMSR) aligned
Production method Micro-batch precision manufacturing
Intended use For Research Use Only (RUO)

Available pack sizes: 500 mL, 1000 mL.

Formulation

Full composition (mg/L)

Complete formulation with CAS numbers, reproduced from manufacturer specification — 37 components across 3 composition tabs (Inorganic Salts, Amino Acids, Vitamins & Others). Custom compositions available on request.

Component CAS Number mg/L
INORGANIC SALTS
Calcium chloride dihydrate 10035-04-8 265.000
Magnesium sulfate anhydrous 7487-88-9 97.720
Potassium chloride 7447-40-7 400.000
Sodium chloride 7647-14-5 6800.000
Sodium dihydrogen phosphate anhydrous 7558-80-7 122.000
Component CAS Number mg/L
AMINO ACIDS
Glycine 56-40-6 7.500
L-Alanine 56-41-7 8.900
L-Arginine hydrochloride 1119-34-2 126.000
L-Asparagine monohydrate   15.000
L-Aspartic acid 56-84-8 13.300
L-Cystine dihydrochloride 30189-89-0 31.300
L-Glutamic acid 56-86-0 14.700
L-Glutamine 56-85-9 292.000
L-Histidine hydrochloride monohydrate 5934-29-2 42.000
L-Isoleucine 73-32-5 52.000
L-Leucine 61-90-5 52.000
L-Lysine hydrochloride 657-27-2 72.500
L-Methionine 63-68-3 15.000
L-Phenylalanine 63-91-2 32.000
L-Proline 147-85-3 11.500
L-Serine 56-45-1 10.500
L-Threonine 72-19-5 48.000
L-Tryptophan 73-22-3 10.000
L-Tyrosine disodium salt dihydrate   51.900
L-Valine 72-18-4 46.000
Component CAS Number mg/L
VITAMINS
Choline chloride 67-48-1 1.000
D-Ca-Pantothenate 137-08-6 1.000
Folic acid 59-30-3 1.000
Nicotinamide 98-92-0 1.000
Pyridoxal hydrochloride 65-22-5 1.000
Riboflavin 83-88-5 0.100
Thiamine hydrochloride 67-03-8 1.000
OTHERS
D-Glucose 50-99-7 4500.000
HEPES 7365-45-9 5958.000
Phenol red sodium salt 34487-61-1 11.000
Sodium pyruvate 113-24-6 110.000
i-Inositol 87-89-8 2.000
Customization: pH, glucose, salt balance, HEPES, and full nutrient profile available on request. Contact support@diagnocine.com.
Quality Assurance

ISO 13485:2016 manufacturing & compliance

Manufactured under an ISO 13485:2016 quality management system, with final packaging, testing, and customization at Diagnocine Precision in Totowa, New Jersey, USA.

verified

ISO 13485:2016 QMS

Full quality management system certification covering manufacturing, testing, and release for every production lot.

water_drop

Ultrapure Type 1 Water

All media prepared with 18.2 MΩ·cm resistivity water for tight trace-metal and organic-carbon control.

biotech

ISO Class 5 Fill & Finish

Aseptic filling in validated ISO Class 5 laminar-flow workstations; 21 CFR Part 820 (QMSR) aligned.

assignment

Micro-Batch Precision

Small-batch manufacturing supports lot-to-lot nutrient consistency for reproducible perfusion studies.

Batch-level quality control. Endotoxin is controlled per manufacturing batch rather than per unit. Every batch is tested before release and must meet the release specification:
  • Endotoxin — LAL assay, USP <85> Bacterial Endotoxins Test; assay sensitivity 0.005 EU/mL; release specification < 0.05 EU/mL
  • pH, osmolality, conductivity, appearance and clarity
  • Sterility
A Certificate of Analysis is available on request.

Endotoxin — USP <85> BET

LAL assay per batch. Release specification: < 0.05 EU/mL.

Particulate — USP <788> Method 1

Light Obscuration Particle Count Test confirms ≥10 µm and ≥25 µm compliance per lot.

Osmolality — USP <785>

Freezing-point osmometry per USP <785>. Result: See CoA.

Documentation — CoA & Full Lot Records

Certificate of Analysis with full QC panel, lot number, expiry, traceability, and release signatures for every lot.

Certificate of Analysis: Request via support@diagnocine.com with your lot number.
Product Comparison

How DCP-MEMGH-B1X (FluxMPS™) compares

Side-by-side comparison against conventional 0.22 µm-filtered MEM High Glucose alternatives.

Parameter DCP-MEMGH-B1X (FluxMPS™) Conventional MEM High Glucose (0.22 µm) Standard MEM High Glucose alternative
Grade Microfluidics Suitable Standard grade (0.22 µm filtered) Standard grade (0.22 µm filtered)
Base formulation MEM High Glucose, NEAA, 25mM HEPES, w/o Sodium Bicarbonate MEM High Glucose Standard MEM High Glucose Equivalent
Final filtration pore size 0.04 µm 0.22 µm 0.22 µm
Number of filtration stages 4 stages 1 stage 1–2 stages
Mycoplasma-retentive filtration check_circle cancel cancel
Endotoxin (release specification) FluxMPS™ — < 0.05 EU/mL Corning classical liquid media — < 0.25 EU/mL
Sigma-Aldrich DMEM complete medium — ≤ 2 EU/mL
Gibco classical DMEM — Not specified (recorded per lot)
USP particulate compliance check_circle USP <788> Method 1 cancel cancel
Water quality Ultrapure Type 1 (18.2 MΩ) Purified water Purified water
Manufacturing QMS ISO 13485:2016 Variable Variable
Microfluidic channel compatibility check_circle Validated cancel Risk of clogging cancel Risk of clogging
Custom formulation check_circle On request cancel Limited

Comparison figures from published supplier specifications, accessed 2026-09-02. Suppliers that publish no numeric endotoxin specification are shown as "Not specified".

FAQ

Frequently asked questions

Common questions about FluxMPS™ Minimum Essential Medium (MEM), High Glucose, NEAA & 25mM HEPES w/o Sodium Bicarbonate: 1X Liquid and Microfluidics Suitable cell culture media.

Yes. DCP-MEMGH-B1X uses our Quadruple-stage filtration (0.1 µm ×2 + 0.04 µm ×2), delivering ultra-low particulate counts that reduce microchannel clogging risk in OoC and MPS devices. It is Microfluidics Suitable at a 0.04 µm final cut-off.
Standard 0.22 µm filtration leaves intact mycoplasma-sized particles (0.2–0.3 µm) and subvisible particulates that accumulate in microchannels. FluxMPS™ uses four sequential stages reaching 0.04 µm, delivering approximately 5× lower particulate counts per USP <788> Method 1 (light obscuration).
The 4.5 g/L (4500 mg/L) glucose level supports metabolically demanding cell types including HeLa, MCF-7, fibroblasts, and high-density suspension cultures. If your cell type requires a lower glucose concentration, contact support@diagnocine.com for a custom formulation.
This formulation is HEPES-buffered and bicarbonate-free, reducing CO₂ dependence. Standard 5–10% CO₂ incubation remains compatible; validate per cell line.
Yes. This medium can be supplemented with FBS (5–20%), growth factors, antibiotics, or other additives per standard practice. Filter serum-containing supplements through a 0.2 µm low-protein-binding PES or PVDF membrane before addition — never a 0.04 µm filter, which will strip serum proteins and clog rapidly. Add supplements immediately before use.
Endotoxin is controlled per manufacturing batch. Every batch is tested by LAL assay per USP <85> BET (assay sensitivity 0.005 EU/mL) and must meet the release specification of < 0.05 EU/mL before release. Lot-specific results are documented in the CoA, available from support@diagnocine.com.
Yes. A lot-specific CoA is available for every shipment and includes: appearance, pH (USP <791>), osmolality (USP <785>), endotoxin (USP <85> BET), sterility (USP <71>), particulate matter (USP <788> Method 1), raw material traceability, lot number, expiry, manufacturing date, and authorized release signatures. Request via support@diagnocine.com.
Scientific References

Supporting literature

Peer-reviewed publications supporting Microfluidics Suitable ultra-filtered media and organ-on-a-chip cell culture applications.

  1. Huh D et al. (2010). Reconstituting organ-level lung functions on a chip. Science, 328(5986), 1662–1668. doi:10.1126/science.1188302
  2. Bhatia SN & Ingber DE (2014). Microfluidic organs-on-chips. Nature Biotechnology, 32(8), 760–772. doi:10.1038/nbt.2989
  3. Eagle H (1959). Amino acid metabolism in mammalian cell cultures. Science, 130(3373), 432–437. doi:10.1126/science.130.3373.432
  4. Warburg O (1956). On the origin of cancer cells. Science, 123(3191), 309–314. doi:10.1126/science.123.3191.309
  5. Bhattacharya S et al. (2018). Challenges in maintaining cell viability during microfluidic experiments. Electrophoresis, 39(7), 997–1006. doi:10.1002/elps.201700375
  6. Zhang YS et al. (2017). Multisensor-integrated organs-on-chips for automated in situ monitoring. PNAS, 114(12), E2293–E2302. doi:10.1073/pnas.1612906114
  7. Vernetti L et al. (2017). Functional coupling of human microphysiology systems. Scientific Reports, 7, 42296. doi:10.1038/srep42296
  8. Esch EW et al. (2015). Organs-on-chips at the frontiers of drug discovery. Nature Reviews Drug Discovery, 14(4), 248–260. doi:10.1038/nrd4539
  9. Zheng F et al. (2021). Organ-on-a-chip systems: microengineering to biomimic living systems. Small, 17(7), 2004175. doi:10.1002/smll.202004175

Satisfaction
Quality Rating
Value Rating
Style Rating
X