FluxMPS™ RPMI 1640 Medium, High Glucose w/o Phenol Red: 1X Liquid

Product#: DCP-RPMIG-R1X
$44.00
DCP-RPMIG-R1X
Availability:
Ships in 1-2 Weeks

warning For Research Use Only (RUO). Not intended for clinical, diagnostic, or therapeutic use in humans.
ISO 13485 Certified Manufacturing

FluxMPS™ RPMI 1640 Medium, High Glucose w/o Phenol Red: 1X Liquid

Contains L-Glutamine Contains Sodium Bicarbonate Contains Calcium Contains Magnesium Contains Glucose Contains Sodium Pyruvate Without Phenol Red Without HEPES

FluxMPS™ RPMI 1640 Medium, High Glucose w/o Phenol Red: 1X Liquid is a Microfluidics Suitable, quadruple-stage ultra-filtered (0.1 µm ×2 + 0.04 µm ×2) 1X liquid cell culture medium engineered for organ-on-a-chip (OoC), tissue-on-a-chip (ToC), and microphysiological system (MPS) applications. A quadruple-stage train (0.1 µm ×2 + 0.04 µm ×2) reaches a 0.04 µm final cut-off, five times finer than the 0.22 µm membranes used for conventional sterile filtration.

  • Quadruple-stage filtration train: 0.1 µm → 0.04 µm → 0.1 µm → 0.04 µm, engineered for microfluidic channel protection
  • Endotoxin release specification: less than 0.05 EU/mL, LAL assay per USP <85> Bacterial Endotoxins Test
  • RPMI 1640 base formulation with 4.5 g/L (high) glucose, 300 mg/L L-glutamine and 110 mg/L sodium pyruvate; phenol red-free for optical and fluorescence-based assays
  • Sodium bicarbonate buffered (2000 mg/L NaHCO3); requires a 5% CO₂ atmosphere to maintain pH 7.4
  • Prepared with Type 1 ultrapure water (18.2 MΩ·cm) under trace-metal and total organic carbon (TOC) control
  • Manufactured under an ISO 13485:2016 quality management system, with final packaging and QC at Diagnocine, Totowa, NJ
  • Every manufacturing batch tested for sterility (14-day USP <71>), endotoxin (USP <85> BET) and particulate matter (USP <788> Method 1) prior to release
  • Custom formulations available — pH, glucose, salts, HEPES, and nutrient composition on request
DCP-RPMIG-R1X | Cell Culture Media Sizes: 500 mL, 1000 mL UNSPSC: 41116155 | Commodity: Molecular biology and cell culture growth media | (UNv260801)
RPMI 1640 Medium, High Glucose w/o Phenol Red: 1X Liquid
  • Glucose4500 mg/L (4.5 g/L)
  • L-Glutamine300 mg/L
  • Sodium Pyruvate110 mg/L
  • HEPESNot added
  • pH (USP <791>)7.4
  • Osmolality (USP <785>)See CoA
  • Endotoxin (USP <85>)< 0.05 EU/mL
  • Filtration0.1 µm ×2 + 0.04 µm ×2
  • Storage2–8°C, protect from light
  • Shelf Life12 months from date of manufacture, unopened
ISO 13485:2016 USP <85> <785> <788> RUO
Why FluxMPS™

Engineered where standard media fails

Conventional 0.22 µm-filtered media carry mycoplasma-sized particulates (0.2–0.3 µm), subvisible debris, and lot-to-lot endotoxin variation that accumulate inside microchannels — corrupting biosensor readings, stressing primary cultures, and shortening device lifetimes. FluxMPS™ is built to address these failure modes at the filtration stage.

filter_alt

Microchannel-safe purity

0.04 µm final filter retains particles down to sub-mycoplasma size; USP <788> Method 1 (light obscuration) particulate compliance verified on every batch.

target

Total metabolic control

Defined 4.5 g/L glucose, 300 mg/L L-glutamine and 110 mg/L sodium pyruvate concentrations support precise metabolic flux experiments and Warburg-effect studies.

water_drop

Ultrapure-grade water

Prepared with Type 1 water (18.2 MΩ·cm) under trace-metal and total organic carbon (TOC) control, minimizing extraneous chemical background from the water source.

visibility

Low background for imaging

Ultra-low particulate baseline supports confocal microscopy, live-cell biosensors, and TEER measurements without introducing subvisible interference into the optical path.

science

Rich, stable nutrient profile

Micro-batch precision manufacturing locks in amino acid and vitamin concentrations, supporting lot-to-lot reproducibility for long-term perfusion studies.

tune

Customization on demand

pH, glucose, salts, HEPES, and full nutrient composition available on request. Contact support@diagnocine.com.

Purity Architecture

Quadruple-stage filtration system

FluxMPS™ RPMI 1640 Medium, High Glucose w/o Phenol Red: 1X Liquid is processed through a four-stage filtration train — two dedicated 0.1 µm prefilter + 0.04 µm final-filter pairs run in series — reaching a 0.04 µm final pore size, addressing mycoplasma-range particulates and subvisible debris that 0.22 µm filtration does not retain.

  1. 1

    0.1 µm Prefiltration I

    Removes large particulates, cell debris and protein aggregates; protects the first 0.04 µm final filter cartridge.

  2. 2

    0.04 µm Final filtration I

    First 0.04 µm pass; retains sub-micron particulates and microaggregates that pass a conventional 0.22 µm filter.

  3. 3

    0.1 µm Prefiltration II

    Second dedicated prefilter, protecting the second 0.04 µm final filter cartridge from breakthrough carried over from Stage 1.

  4. 4

    0.04 µm Final filtration II — Polish

    Ultimate polishing filter; aseptic fill & finish in a validated ISO Class 5 laminar-flow workstation.

Performance vs. conventional media

Four sequential stages reaching 0.04 µm deliver approximately 5× cleaner media by particulate count compared to single-pass 0.22 µm filtration.

5×
 
0.04
µm final filter pore size — sub-mycoplasma polishing
Sterility assurance: Every batch undergoes 14-day USP <71> sterility testing. Mycoplasma risk is controlled by 0.1 µm mycoplasma-retentive filtration; the medium is not individually tested to USP <63> per lot.
Grade: This product is Microfluidics Suitable, filtered to a 0.04 µm final cut-off. It is not an MPS Grade product — that designation is reserved for the 0.01 µm ultra nano-filtered line, which adds 0.02 µm and 0.01 µm stages after the 0.04 µm polish. For applications requiring the 0.01 µm cut-off, contact support@diagnocine.com.
FluxMPS RPMI 1640 Medium, High Glucose w/o Phenol Red: 1X Liquid (DCP-RPMIG-R1X) Quadruple-stage filtration system: 0.1 micron Prefiltration I, 0.04 micron Final filtration I, 0.1 micron Prefiltration II, 0.04 micron Final filtration II Polish for organ-on-a-chip and microfluidic applications by Diagnocine
Figure 1. FluxMPS™ Quadruple-stage filtration architecture (0.1 µm ×2 + 0.04 µm ×2).
© Diagnocine® — DCP-RPMIG-R1X
Applications

Designed for next-generation cell culture platforms

FluxMPS™ RPMI 1640 Medium, High Glucose w/o Phenol Red: 1X Liquid is suited to organ-on-a-chip, metabolic research, live-cell imaging, and primary cell models where particulate load and endotoxin variability must be controlled.

Automated Bioreactors & Robotics

Next-Generation System Uptime

An optional 0.01 µm (10 nm) ultra nano-filtered MPS Grade variant of this RPMI 1640 formulation is available for automated bioreactor and robotic perfusion systems requiring the highest particulate exclusion.

  • Total Particulate Exclusion: 0.01 µm filtration for nanoscale valve and sensor protection
  • Valve & Sensor Protection: prevents particulate-induced blockage in precision fluidic systems
  • Extended Perfusion Stability: maintains flow rate consistency across multi-week automated runs

Inquiry Required: Contact support@diagnocine.com to request the 0.01 µm MPS Grade formulation.

Microfluidics

Micro Physiological System (MPS) & Chip

Ultra-filtered formulation supports microchannel integrity and laminar flow in chip-based devices.

OoCToCBoCLoCMPS
Cancer Biology

Warburg Effect & Metabolic Research

High-glucose base with defined pyruvate content supports precise metabolic flux analysis in tumor cell models.

MCF-7MDA-MB-231HeLaA549
Stem Cell Biology

iPSC-Derived Models

Ultra-filtered, phenol red-free formulation supports sensitive iPSC differentiation and imaging protocols.

iPSC-NeuronsiPSC-CMiPSC-Hep
Vascular Biology

Endothelial & Primary Cells

Microchannel-safe purity supports endothelial barrier integrity and TEER measurement in vascular models.

HUVECsHAECsPrimary hepatocytes
Metabolomics

Metabolic Flux Analysis

Defined nutrient base supports isotope-tracing workflows. Not compatible with Agilent Seahorse XF assays, which require bicarbonate-free, phenol red-free medium; this formulation contains sodium bicarbonate.

13C tracingNMR metabolomics
Live-Cell Imaging

Microscopy & Optical Sensing

Phenol red-free base and ultra-low particulate load support confocal imaging and optical biosensor workflows.

ConfocalBiosensorsTEER
Technical Specifications

Batch-release quality parameters

Every production batch of FluxMPS™ RPMI 1640 Medium, High Glucose w/o Phenol Red: 1X Liquid undergoes the quality-release battery below before shipment.

Physical & Chemical Parameters
Parameter Specification
Formulation RPMI 1640 High Glucose base: L-Glutamine, Sodium Bicarbonate, Calcium, Magnesium, Glucose (4.5 g/L) and Sodium Pyruvate present; Phenol Red and HEPES not added
Appearance Colorless to pale yellow, clear solution — phenol red-free
pH USP <791> 7.4
Osmolality USP <785> See CoA
Glucose 4500 mg/L (4.5 g/L)
L-Glutamine 300 mg/L
Sodium Pyruvate 110 mg/L
Phenol Red Not added
Sterility, Purity & Safety Parameters
Parameter Specification
Endotoxin USP <85> BET < 0.05 EU/mL
Sterility USP <71> No growth after 14 days
Mycoplasma 0.1 µm mycoplasma-retentive filtration (not tested per lot)
Particulate ≥10 µm USP <788> Method 1 Compliant
Particulate ≥25 µm USP <788> Method 1 Compliant
Water purity Ultrapure Type 1, 18.2 MΩ·cm (ASTM D1193 / ISO 3696)
Manufacturing std. ISO 13485 ISO 13485:2016
Fill environment ISO Class 5 (Class 100)
Storage, Handling & Logistics
Parameter Specification
Storage temperature 2–8°C, protected from light
Freeze-thaw Not recommended
Shelf life 12 months from date of manufacture, unopened
Shipping condition Cold pack
CO₂ requirement 5% CO₂ required (derived from 2000 mg/L NaHCO3 to maintain pH 7.4)
Raw Materials & Regulatory Traceability
Parameter Specification
Raw material grade Cell culture / reagent grade
Traceability Full lot documentation, CoA available
Manufacturing QMS ISO 13485:2016 certified
UNSPSC 41116155 — Molecular biology and cell culture growth media (UNv260801)
Regulatory alignment 21 CFR Part 820 (QMSR) aligned
Production method Micro-batch precision manufacturing
Intended use For Research Use Only (RUO)
Formulation

Full composition (mg/L)

Complete formulation with CAS numbers, 40 components across 4 categories. All ingredient names and mg/L values reproduced from the manufacturer specification. Custom compositions available on request.

Component CAS Number mg/L
INORGANIC SALTS
Calcium nitrate tetrahydrate 13477-34-4 100.000
Magnesium sulfate anhydrous 7487-88-9 48.840
Potassium chloride 7447-40-7 400.000
Sodium bicarbonate 144-55-8 2000.000
Sodium chloride 7647-14-5 6000.000
Sodium phosphate dibasic anhydrous 7558-79-4 800.000
Component CAS Number mg/L
AMINO ACIDS
Glycine 56-40-6 10.000
L-Arginine hydrochloride 1119-34-2 241.000
L-Asparagine 70-47-3 50.000
L-Aspartic acid 56-84-8 20.000
L-Cystine dihydrochloride 30189-89-0 65.200
L-Glutamic acid 56-86-0 20.000
L-Glutamine 56-85-9 300.000
L-Histidine hydrochloride monohydrate 5934-29-2 20.960
L-Hydroxyproline 51-35-4 20.000
L-Isoleucine 73-32-5 50.000
L-Leucine 61-90-5 50.000
L-Lysine hydrochloride 657-27-2 40.000
L-Methionine 63-68-3 15.000
L-Phenylalanine 63-91-2 15.000
L-Proline 147-85-3 20.000
L-Serine 56-45-1 30.000
L-Threonine 72-19-5 20.000
L-Tryptophan 73-22-3 5.000
L-Tyrosine Disodium Salt 69847-45-6 28.830
L-Valine 72-18-4 20.000
Component CAS Number mg/L
VITAMINS
Choline chloride 67-48-1 3.000
D-Biotin 58-85-5 0.200
D-Ca-Pantothenate 137-08-6 0.250
Folic acid 59-30-3 1.000
Niacinamide 98-92-0 1.000
Pyridoxine hydrochloride 58-56-0 1.000
Riboflavin 83-88-5 0.200
Thiamine hydrochloride 67-03-8 1.000
Vitamin B12 68-19-9 0.005
i-Inositol 87-89-8 35.000
p-Amino benzoic acid (PABA) 150-13-0 1.000
OTHERS
D-Glucose 50-99-7 4500.000
Glutathione reduced 70-18-8 1.000
Sodium Pyruvate 113-24-6 110.000
Customization: pH, glucose, salt balance, HEPES, and full nutrient profile available on request. Contact support@diagnocine.com.
Quality Assurance

ISO 13485:2016 manufacturing & compliance

Manufactured under an ISO 13485:2016 quality management system, with final packaging, testing, and customization at Diagnocine, Totowa, New Jersey, USA.

verified

ISO 13485:2016 QMS

Full quality management system certification covering manufacturing, testing, and release for every production batch.

water_drop

Ultrapure Type 1 Water

All media prepared with 18.2 MΩ·cm resistivity Type 1 water under trace-metal and TOC control.

biotech

ISO Class 5 Fill & Finish

Aseptic filling in validated ISO Class 5 laminar-flow workstations; 21 CFR Part 820 (QMSR) aligned.

assignment

Micro-Batch Precision

Small-batch manufacturing supports lot-to-lot nutrient consistency for reproducible perfusion studies.

Endotoxin — USP <85> BET

LAL assay performed on every manufacturing batch. Assay sensitivity 0.005 EU/mL. Release specification: < 0.05 EU/mL.

Particulate — USP <788> Method 1

Light obscuration particle count confirms ≥10 µm and ≥25 µm compliance on every batch.

Osmolality — USP <785>

Freezing-point osmometry per USP <785>. Result documented in the Certificate of Analysis (See CoA).

Documentation — CoA & Full Batch Records

Certificate of Analysis with full QC panel, raw material traceability, and release signatures for every batch.

Batch-level quality control. Endotoxin is controlled per manufacturing batch rather than per unit. Every batch is tested before release and must meet the release specification:
  • Endotoxin — LAL assay, USP <85> Bacterial Endotoxins Test; assay sensitivity 0.005 EU/mL; release specification < 0.05 EU/mL
  • pH, osmolality, conductivity, appearance and clarity
  • Sterility
A Certificate of Analysis is available on request via support@diagnocine.com.
Product Comparison

How DCP-RPMIG-R1X (FluxMPS™) compares

Side-by-side comparison against conventional 0.22 µm-filtered alternatives of the same base formulation.

Parameter DCP-RPMIG-R1X (FluxMPS™) Conventional RPMI 1640 (0.22 µm) Standard RPMI 1640 alternative
Grade Microfluidics Suitable Standard grade Standard grade
Base formulation RPMI 1640, High Glucose, w/o Phenol Red RPMI 1640 Standard RPMI 1640 Equivalent
Final filtration pore size 0.04 µm 0.22 µm 0.22 µm
Number of filtration stages 4 stages 1 stage 1–2 stages
Mycoplasma-retentive filtration check_circle cancel cancel
Endotoxin (release specification) < 0.05 EU/mL Corning classical liquid media — < 0.25 EU/mL
Sigma-Aldrich DMEM complete medium — ≤ 2 EU/mL
Gibco classical DMEM — Not specified (recorded per lot)
USP particulate compliance check_circle USP <788> Method 1 cancel cancel
Water quality Ultrapure Type 1 (18.2 MΩ·cm) Purified water Purified water
Manufacturing QMS ISO 13485:2016 Variable Variable
Microfluidic channel compatibility check_circle Validated cancel Risk of clogging cancel Risk of clogging
Custom formulation check_circle On request cancel Limited

Comparison figures from published supplier specifications, accessed 2026-09-02. Suppliers that publish no numeric endotoxin specification are shown as "Not specified".

FAQ

Frequently asked questions

Common questions about FluxMPS™ RPMI 1640 Medium, High Glucose w/o Phenol Red: 1X Liquid and Microfluidics Suitable cell culture media.

Yes. DCP-RPMIG-R1X uses a quadruple-stage filtration train (0.1 µm ×2 + 0.04 µm ×2), delivering ultra-low particulate counts that support microchannel integrity in OoC and MPS devices.
Standard 0.22 µm filtration does not retain mycoplasma-range particulates (0.2–0.3 µm) or subvisible debris that accumulate in microchannels. FluxMPS™ uses four sequential stages reaching 0.04 µm, delivering approximately 5× lower particulate counts by count under USP <788> Method 1.
Phenol red is a pH indicator dye that can interfere with fluorescence, absorbance and colorimetric assays; this formulation omits it for optical and imaging workflows. HEPES buffering is also not added and can be included on request for CO₂-independent culture. Contact support@diagnocine.com for custom formulations.
Yes. This formulation contains 2000 mg/L sodium bicarbonate and is buffered to pH 7.4 under a 5% CO₂ atmosphere; a CO₂ incubator is required to maintain physiological pH.
Yes. FluxMPS™ RPMI 1640 Medium, High Glucose w/o Phenol Red: 1X Liquid can be supplemented with FBS (typically 5–20%), growth factors, or antibiotics per standard practice. When filtering serum or protein-containing supplements, use a 0.2 µm low-protein-binding PES or PVDF filter — never a 0.04 µm membrane, which retains serum proteins and lipoproteins. Add supplements immediately before use.
Endotoxin is controlled per manufacturing batch. Every batch is tested by LAL assay per USP <85> BET (assay sensitivity 0.005 EU/mL) and must meet the release specification of < 0.05 EU/mL before shipment. Batch-specific results are documented in the Certificate of Analysis, available from support@diagnocine.com.
Yes. A batch-specific CoA is available for every shipment and includes: appearance, pH (USP <791>), osmolality (USP <785>), endotoxin (USP <85> BET), sterility (USP <71>), particulate matter (USP <788> Method 1), raw material traceability, manufacturing date, lot number, expiry, and authorized release signatures. Request via support@diagnocine.com.
Scientific References

Supporting literature

Peer-reviewed publications supporting the scientific rationale for ultra-filtered media, RPMI 1640-based culture, and microfluidic cell culture applications.

  1. Moore GE et al. (1967). Culture of normal human leukocytes. JAMA, 199(8), 519–524. doi:10.1001/jama.1967.03120080053007
  2. Huh D et al. (2010). Reconstituting organ-level lung functions on a chip. Science, 328(5986), 1662–1668. doi:10.1126/science.1188302
  3. Bhatia SN & Ingber DE (2014). Microfluidic organs-on-chips. Nature Biotechnology, 32(8), 760–772. doi:10.1038/nbt.2989
  4. Bhattacharya S et al. (2018). Challenges in maintaining cell viability during microfluidic experiments. Electrophoresis, 39(7), 997–1006. doi:10.1002/elps.201700375
  5. Warburg O (1956). On the origin of cancer cells. Science, 123(3191), 309–314. doi:10.1126/science.123.3191.309
  6. Kim S et al. (2012). Gut-on-a-chip microdevice replicates key functional features of the human intestine. Lab on a Chip, 12(12), 2165–2174. doi:10.1039/c2lc40074j
  7. Zhang YS et al. (2017). Multisensor-integrated organs-on-chips platform for automated in situ monitoring. PNAS, 114(12), E2293–E2302. doi:10.1073/pnas.1612906114
  8. Vernetti L et al. (2017). Functional coupling of human microphysiology systems. Scientific Reports, 7, 42296. doi:10.1038/srep42296
  9. Zheng F et al. (2021). Organ-on-a-chip systems: microengineering to biomimic living systems. Small, 17(7), 2004175. doi:10.1002/smll.202004175
  10. Esch EW et al. (2015). Organs-on-chips at the frontiers of drug discovery. Nature Reviews Drug Discovery, 14(4), 248–260. doi:10.1038/nrd4539

Satisfaction
Quality Rating
Value Rating
Style Rating
X