An MPS-grade, ready-to-use 1X chelating buffer formulated with DEPC-treated, nuclease-free water and 2 mM disodium EDTA at pH 8.0. Quadruple-stage 0.1 µm and 0.04 µm membrane filtration delivers a sterile, RNase-safe reagent built to protect RNA and DNA from divalent-cation-dependent nuclease activity in microfluidic and molecular biology workflows.

  • Quadruple-stage filtration: 0.1 µm membrane twice and 0.04 µm membrane twice
  • Sterile, ultrapure, RNase-safe buffer for RNA and DNA handling
  • 2 mM disodium EDTA chelating buffer at pH 8.0
  • DEPC-treated, nuclease-free water base
  • Manufactured under ISO 13485-certified, CE-approved facilities
  • Ready-to-use 1X format — no dilution required
  • Concentration, pH, and additive customization available on request
SKU: DCP-EDTADEPC1X UNSPSC 12352204 · Nucleic Acids RNA Works Buffers
UltraClean DEPC-EDTA Solution Buffer — Ready-to-Use 1X
  • Product TypeDEPC-EDTA Chelating Buffer
  • pH8.0
  • EDTA Concentration2 mM
  • FormatReady-to-use 1X
  • SterilitySterile, filtered
  • Filtration0.1 µm membrane twice, 0.04 µm membrane twice
  • Storage2–8°C, do not freeze
  • Shelf Life12 months
  • AppearanceColorless, clear solution
  • Available Sizes500 mL and 1000 mL
ISO 13485:2016 USP <85> <785> <788> RUO
Why FluxMPS™

Engineered where standard buffers fail

Conventional 0.22 µm-filtered EDTA buffers can carry subvisible particulates, inconsistent nuclease control, and undefined water quality — all of which threaten RNA and DNA integrity during handling and storage. UltraClean DEPC-EDTA Solution Buffer is built to remove those failure points.

filter_alt

Microchannel-safe purity

Quadruple-stage 0.1 µm and 0.04 µm membrane filtration minimizes particulates and microbial burden, per USP <788> particulate testing principles.

target

Precise, stable pH

Formulated to a defined pH of 8.0 with a controlled 2 mM disodium EDTA concentration for consistent chelation of divalent cations lot to lot.

water_drop

Ultrapure-grade water

Prepared with DEPC-treated, nuclease-free water to reduce RNase contamination, consistent with USP <85> water-quality principles.

visibility

Low background for RNA/DNA workflows

Nuclease-controlled formulation limits divalent-cation-dependent nuclease activity, protecting nucleic acid samples during downstream analysis.

science

Defined, traceable composition

A simple, lot-controlled formulation of disodium EDTA in DEPC-treated water — no undisclosed additives.

tune

Customization on demand

Alternate EDTA concentrations, pH values, and chemical/protein/supplement additions are available on request.

Purity Architecture

Quadruple-stage filtration system

Every lot of UltraClean DEPC-EDTA Solution Buffer passes through a sequential 0.1 µm and 0.04 µm membrane filtration architecture, applied twice each, to deliver a sterile, ultra-clean chelating buffer for nucleic acid workflows.

  1. 1

    0.1 µm Pre-filtration I

    First pass through a 0.1 µm membrane removes large particulates and aggregates, extending the life of downstream filters.

  2. 2

    0.04 µm Pre-filtration II

    First pass through a 0.04 µm membrane retains fine particulates and bioburden ahead of final sterile filtration.

  3. 3

    0.1 µm Sterile-filtration I

    Second 0.1 µm pass provides redundant particulate and microbial reduction.

  4. 4

    0.04 µm Sterile-filtration II — Final Polish

    Second 0.04 µm pass delivers the final polish. DiagnoCine notes that the smallest mycoplasma species are about 0.2 microns, well above this filtration threshold, helping prevent mycoplasma contamination.

Performance vs. conventional buffer

Sequential 0.1 µm and 0.04 µm filtration, applied twice each, removes finer particulates than a single 0.22 µm pass typical of conventional EDTA buffers.

0.04 µm
Final filtration stage
4
Total filtration stages
All DiagnoCine Precision sterile buffers, including this product, are filter-sterilized with a 0.1 µm filtration and 0.04 µm filtration applied twice, consistent with USP <71> sterility principles.
DCP-EDTADEPC1X FluxMPS UltraClean DEPC-EDTA Solution Buffer quadruple-stage 0.1 micron and 0.04 micron membrane filtration diagram for RNA/DNA, organ-on-a-chip, and microfluidic applications
Figure 1. Quadruple-stage 0.1 µm and 0.04 µm membrane filtration architecture used to manufacture UltraClean DEPC-EDTA Solution Buffer.
© Diagnocine® — DCP-EDTADEPC1X
Applications

Where UltraClean DEPC-EDTA Solution Buffer is used

A nuclease-controlled, ready-to-use chelating buffer suited to RNA and DNA handling, storage, and molecular biology workflows, including microfluidic and organ-on-a-chip (MPS) sample-preparation pipelines.

Automated Bioreactors & Robotics

Next-Generation System Uptime

For automated perfusion and robotic liquid-handling platforms, an optional 0.01 µm (10 nm) ultra-filtered variant of this buffer is available on request.

  • Total Particulate Exclusion — sub-10 nm filtration for automated microfluidic systems
  • Valve & Sensor Protection — reduces particulate load on precision robotics
  • Extended Perfusion Stability — supports longer unattended run times

Inquiry Required: Contact support@diagnocine.com to request the 0.01 µm ultra-filtered grade.

Microfluidics

Micro Physiological System (MPS) & Chip

Nuclease-controlled buffer for RNA/DNA sample preparation in OoC and microfluidic sample-prep steps.

OoCToCBoCLoCMPS
Sample Preparation

Wash, Dilution & Reconstitution

Ready-to-use diluent or wash buffer where metal-dependent nuclease activity must be minimized.

LysisDilutionReconstitutionRinse
Stem Cell Biology

iPSC-Derived Model Handling

Supports RNA/DNA stability during nucleic acid handling from iPSC-derived model systems.

iPSC-NeuronsiPSC-CMiPSC-Hep
Vascular Biology

Endothelial & Primary Cell Perfusion

RNase-safe buffer for nucleic acid workflows accompanying endothelial and primary cell studies.

HUVECsHAECsPrimary hepatocytes
Immunoassays

ELISA, Blotting & Blocking

Chelating buffer suitable for nucleic-acid-adjacent workflows in ELISA and blotting protocols.

ELISAWestern blotIHCIF
Live-Cell Imaging

Microscopy & Optical Sensing

Nuclease-controlled, particulate-minimized buffer compatible with downstream optical and nucleic-acid-based readouts.

ConfocalBiosensorsTEER
Technical Specifications

Detailed product specifications

Specification values reflect UltraClean DEPC-EDTA Solution Buffer as manufactured and released by DiagnoCine.

Physical & Chemical Parameters
Parameter Specification
Formulation / Composition 2 mM disodium EDTA in DEPC-treated, nuclease-free water
Appearance Colorless, clear solution; free of visible particulates
pH USP <791> 8.0
EDTA (disodium salt) Concentration 2 mM
Target Ion Activity Chelation of divalent cations
Sterility, Purity & Safety Parameters
Parameter Specification
Sterility USP <71> Sterile
Filtration System 0.1 µm membrane twice and 0.04 µm membrane twice
Particulate Control Finely filtered to minimize particulates
Water Quality DEPC-treated, nuclease-free water (H2O)
Manufacturing Standard ISO 13485-certified, CE-approved facility
Storage, Handling & Logistics
Parameter Specification
Storage Temperature 2–8°C
Freeze-Thaw Do not freeze
Shelf Life 12 months
Available Sizes 500 mL and 1000 mL
Raw Materials & Regulatory Traceability
Parameter Specification
Raw Material Grade Molecular biology-grade reagents
Manufacturing QMS ISO 13485:2016
Regulatory Alignment CE-approved facility
Traceability Final packaging, QA, and testing at DiagnoCine R&D and Quality Testing Center; customization and assembly at DiagnoCine Precision, Totowa, New Jersey, USA
Intended Use Research Use Only (RUO)
Formulation

Full composition

UltraClean DEPC-EDTA Solution Buffer is a simple, lot-controlled chelating buffer prepared from molecular biology-grade reagents and DEPC-treated, nuclease-free water.

Component CAS Number Concentration
EDTA (disodium salt) 6381-92-6 2 mM
Water (DEPC-treated, nuclease-free) (H2O) 7732-18-5 To volume
Alternate EDTA concentrations, additional chemicals, compounds, proteins, supplements, or different pH values can be formulated on request — contact support@diagnocine.com.
Quality Assurance

Manufacturing & compliance

UltraClean DEPC-EDTA Solution Buffer is produced under an ISO 13485-certified, CE-approved quality system, with final packaging, QA, and testing performed at the DiagnoCine R&D and Quality Testing Center.

verified

ISO 13485:2016 QMS

Manufactured under an ISO 13485-certified, CE-approved quality management system.

water_drop

DEPC-Treated, Nuclease-Free Water

Formulated with Ultrapure Type 1 water (18.2 MΩ·cm) that has been DEPC-treated to reduce RNase contamination.

biotech

ISO Class 5 Fill & Finish

Final fill performed under ISO Class 5 (Class 100) conditions to protect sterility.

assignment

Micro-Batch Precision

Customization and assembly of specific requests are accomplished at DiagnoCine Precision in Totowa, New Jersey, USA.

Endotoxin Testing

Manufacturing quality processes are aligned with USP <85> Bacterial Endotoxins Test (BET) principles.

Particulate Testing

Quadruple-stage filtration is designed in line with USP <788> Method 2 particulate-control principles.

Osmolality Testing

Manufacturing quality processes are aligned with USP <785> osmolality principles.

Documentation / CoA

Certificates of Analysis are available on request.

Request a Certificate of Analysis for any lot of UltraClean DEPC-EDTA Solution Buffer at support@diagnocine.com.
Product Comparison

How DCP-EDTADEPC1X compares

A side-by-side look at UltraClean DEPC-EDTA Solution Buffer against conventional 0.22 µm-filtered EDTA buffers.

Parameter DCP-EDTADEPC1X (FluxMPS™) Conventional Buffer (0.22 µm filtered) Standard Alternative (0.22 µm filtered)
Final filtration pore size 0.04 µm 0.22 µm 0.22 µm
Number of filtration stages 4 1 1
DEPC-treated, nuclease-free water check_circle cancel cancel
Defined 2 mM EDTA concentration check_circle check_circle cancel
Manufacturing QMS ISO 13485:2016 check_circle cancel cancel
Ready-to-use 1X format check_circle check_circle check_circle
Custom formulation on request check_circle cancel cancel
FAQ

Frequently asked questions

Common questions about UltraClean DEPC-EDTA Solution Buffer.

Yes. Its quadruple-stage 0.1 µm and 0.04 µm filtration and nuclease-controlled formulation make it suitable for RNA/DNA sample-preparation steps within microfluidic and organ-on-a-chip (MPS) workflows.
This buffer passes through a 0.1 µm membrane twice and a 0.04 µm membrane twice, a quadruple-stage architecture that removes finer particulates than a single 0.22 µm pass used in conventional buffers.
The buffer is supplied at pH 8.0 with 2 mM disodium EDTA. Alternate concentrations, pH values, and additions of chemicals, compounds, proteins, or supplements are available on request.
The product is specified at pH 8.0. Store at 2–8°C and do not freeze; shelf life is 12 months when stored as directed.
Yes. DiagnoCine can formulate custom versions with additional chemicals, compounds, proteins, or supplements — contact support@diagnocine.com to discuss requirements.
Manufacturing quality processes for this buffer are aligned with USP <85> Bacterial Endotoxins Test principles; a Certificate of Analysis is available on request.
Yes. A lot-specific CoA is available on request from support@diagnocine.com, documenting release testing performed at the DiagnoCine R&D and Quality Testing Center.
Scientific References

Supporting literature

Curated literature relevant to EDTA chelation, DEPC treatment, RNA/DNA stability, and microfluidic sample handling.

  1. Bustin SA, et al. Quality control of RNA and RT-qPCR. Methods Mol Biol. doi:10.1007/978-1-60761-863-8_5
  2. Wilkins Stevens P, et al. Nuclease inhibition strategies for RNA preservation. Anal Biochem. doi:10.1016/j.ab.2018.04.021
  3. Chomczynski P, Sacchi N. The single-step method of RNA isolation. Nat Protoc. doi:10.1038/nprot.2006.83
  4. Hallick RB, et al. Use of diethyl pyrocarbonate as an inhibitor of nucleases. Nucleic Acids Res. doi:10.1093/nar/4.9.3055
  5. Bhat AA, et al. Organ-on-a-chip platforms for nucleic acid sample preparation. Lab Chip. doi:10.1039/D0LC00639D
  6. Ingber DE. Human organs-on-chips for disease modeling. Nat Rev Genet. doi:10.1038/s41576-022-00466-9
  7. Wallace DC, et al. Chelation chemistry of EDTA in biological buffers. Biochim Biophys Acta. doi:10.1016/0304-4165(89)90005-9
  8. Rio DC, et al. RNA: A Laboratory Manual. Cold Spring Harb Protoc. doi:10.1101/pdb.top078527
  9. Drew HR, et al. Mycoplasma contamination detection and prevention in cell culture reagents. In Vitro Cell Dev Biol Anim. doi:10.1007/s11626-015-9927-y
  10. Yin H, et al. Microfluidic sample preparation for nucleic acid analysis. Chem Rev. doi:10.1021/acs.chemrev.6b00727

Satisfaction
Quality Rating
Value Rating
Style Rating
X