FluxMPS™ Waymouth Medium w/o Sodium Bicarbonate: 1X Liquid

Product#: DCP-WMBM-B1X
$46.20
DCP-WMBM-B1X
Availability:
Ships in 1-2 Weeks

warning For Research Use Only (RUO). Not intended for clinical, diagnostic, or therapeutic use in humans.
verified ISO 13485 Certified Manufacturing

FluxMPS™ Waymouth Medium w/o Sodium Bicarbonate

Contains L-Glutamine Contains Phenol Red Contains Calcium Contains Magnesium Contains Glucose Without Sodium Bicarbonate

Microfluidics Suitable, quadruple-stage ultra-filtered (0.1 µm ×2 + 0.04 µm ×2) 1X liquid Waymouth Medium MB 752/1 formulated without sodium bicarbonate, for CO₂-independent culture of hybridomas, fibroblasts, and other mammalian cell lines on microfluidic, organ-on-a-chip (OoC), and microphysiological system (MPS) platforms. A quadruple-stage train (0.1 µm ×2 + 0.04 µm ×2) reaches a 0.04 µm final cut-off, five times finer than the 0.22 µm membranes used for conventional sterile filtration. Formulation: [+] Glucose (5 g/L), [+] L-Glutamine, [+] Phenol Red, [+] Calcium, [+] Magnesium | [-] Sodium Bicarbonate.

  • Waymouth MB 752/1 formulation with 5000 mg/L (5.0 g/L) D-glucose as the primary carbon source
  • 350 mg/L L-glutamine plus 15 mg/L reduced glutathione for nitrogen and redox support
  • Formulated without sodium bicarbonate; phosphate-buffered for CO₂-independent culture (HEPES supplementation optional)
  • Processed through a Quadruple-stage filtration system (0.1 µm ×2 + 0.04 µm ×2) reaching a 0.04 µm final cut-off
  • Endotoxin release specification < 0.05 EU/mL (LAL, USP <85>), verified per manufacturing batch
  • Contains phenol red sodium salt (11 mg/L) as a pH indicator; red-colored, clear solution
  • Manufactured under an ISO 13485:2016 quality management system with full lot traceability
  • 40 characterized components across inorganic salts, amino acids, vitamins, and specialty additives, released with a per-lot Certificate of Analysis
CAT. NO.
DCP-WMBM-B1X | Cell Culture Media UNSPSC: 41116155 | Commodity: Molecular biology and cell culture growth media | (UNv260801)
Waymouth Medium MB 752/1 — 1X Liquid
  • Media familyWaymouth Medium MB 752/1
  • Glucose5000 mg/L (5.0 g/L)
  • Formulation[+] Glucose, [+] L-Glutamine, [+] Phenol Red, [+] Calcium, [+] Magnesium | [-] Sodium Bicarbonate
  • AppearanceRed-colored, clear solution
  • pH (USP <791>)7.4
  • Osmolality (USP <785>)240 – 345 mOsm/kg H2O
  • Endotoxin (USP <85>)< 0.05 EU/mL
  • Filtration0.1 µm ×2 + 0.04 µm ×2
  • Storage2–8°C, protect from light
  • Shelf Life12 months from date of manufacture, unopened
ISO 13485:2016 USP <85> <785> <788> RUO
Why FluxMPS™

Engineered where standard media fails

Conventional 0.22 µm–filtered Waymouth Medium passes subvisible particulates and organisms that clog microfluidic channels and interfere with sensitive assays. FluxMPS™ is built to a finer standard.

filter_alt

Microchannel-safe purity

0.04 µm final filtration with USP <788> Method 1 particulate compliance, together with a < 0.05 EU/mL endotoxin release specification (USP <85>), supports use with TLR4-sensitive primary cell types and narrow-geometry microfluidic channels.

target

Defined nutrient control

5000 mg/L D-glucose, 350 mg/L L-glutamine, and 15 mg/L reduced glutathione provide a phosphate-buffered nutrient base for hybridoma, fibroblast, and other demanding cell types requiring the Waymouth MB 752/1 formulation.

water_drop

Ultrapure-grade water

Type 1 water (18.2 MΩ·cm) with trace-metal and organic-carbon (TOC) control minimizes trace contaminant carryover into every formulation.

visibility

Low background for imaging

The 0.04 µm final filtration establishes an ultra-low particulate baseline suited to confocal microscopy and biosensor-based assays; phenol-red-free formulations are available on request for fluorescence-sensitive applications requiring minimal background.

science

Rich, stable nutrient profile

40 characterized components across inorganic salts, amino acids, vitamins, and specialty additives — including 15 mg/L reduced glutathione — released via micro-batch, per-lot quality control.

tune

Customization on demand

pH, nutrient concentrations, HEPES buffering, and other component modifications available on request. Contact support@diagnocine.com.

Purity Architecture

Quadruple-stage filtration system

Four serial filtration stages — two prefilter + final-filter pairs — reaching a final 0.04 µm polish under ISO Class 5 aseptic conditions.

  1. 1

    0.1 µm Prefiltration I

    Removes large aggregates and particulate; protects the first 0.04 µm cartridge.

  2. 2

    0.04 µm Final filtration I

    First 0.04 µm pass; retains sub-micron particulates and microaggregates that pass a standard 0.22 µm filter.

  3. 3

    0.1 µm Prefiltration II

    A second, dedicated prefilter protecting the second 0.04 µm cartridge.

  4. 4

    0.04 µm Final filtration II — Polish

    Ultimate polishing filter; aseptic fill & finish under ISO Class 5 (Class 100) conditions.

Purity architecture, stated plainly

FluxMPS™ DCP-WMBM-B1X runs two dedicated 0.1 µm prefilter + 0.04 µm final-filter pairs in series, ending at a 0.04 µm final cut-off — five times finer than the 0.22 µm membranes used for conventional sterile filtration.

4
Filtration passes (two prefilter + final-filter pairs)
0.04
µm final pore size
Sterility & size-exclusion: No growth after 14-day incubation (USP <71>). The 4-stage train (0.1 µm ×2 + 0.04 µm ×2) is sized to retain organisms in the 0.2–0.3 µm range, including mycoplasma; mycoplasma testing is not performed on every lot.
Grade: This product is Microfluidics Suitable, filtered to a 0.04 µm final cut-off. It is not an MPS Grade product — that designation is reserved for the 0.01 µm ultra nano-filtered line, which adds 0.02 µm and 0.01 µm stages after the 0.04 µm polish. For applications requiring the 0.01 µm cut-off, contact support@diagnocine.com.
FluxMPS DCP-WMBM-B1X Waymouth Medium Quadruple-stage filtration system, four stages (0.1 micron x2 + 0.04 micron x2), Microfluidics Suitable for organ-on-a-chip and microphysiological system applications, Diagnocine
Figure 1. FluxMPS™ Quadruple-stage filtration system (0.1 µm ×2 + 0.04 µm ×2) used in DCP-WMBM-B1X production.
© Diagnocine® — DCP-WMBM-B1X
Applications

Specialized cell culture applications

FluxMPS™ DCP-WMBM-B1X — Waymouth Medium MB 752/1 without sodium bicarbonate — delivers 0.04 µm filtered, Microfluidics Suitable purity for mammalian cell culture and related microfluidic applications.

Automated Bioreactors & Robotics

Next-Generation System Uptime

An optional 0.01 µm (10 nm) ultra nano-filtered MPS Grade variant of this formulation is available on request for automated bioreactor and robotic perfusion systems.

  • Total Particulate Exclusion: 0.01 µm filtration removes nanoparticulate aggregates
  • Valve & Sensor Protection: Reduces micro-fouling risk in automated perfusion systems
  • Extended Perfusion Stability: Consistent nutrient delivery over long-duration culture

Inquiry Required: Contact support@diagnocine.com for the 0.01 µm MPS Grade variant.

Bioproduction

CHO & Mammalian Cell Culture

Supports CHO, hybridoma, myeloma, and primary fibroblast culture in serum-free or low-serum conditions.

CHOHybridomaMyeloma
Microfluidics

Organ-on-a-Chip & MPS

Ultra-filtered to a 0.04 µm final pore size, reducing particulate load and channel-obstruction risk in complex multi-organ chip architectures.

OoCToCMPS
Cancer Biology

Cancer Cell Lines

Supports fibroblast co-culture tumor models and primary cancer cell culture in the defined nutrient environment of Waymouth Medium.

Tumor modelsFibroblastsCo-culture
Stem Cell Biology

Primary & Stem Cell Support

Rich nutrient profile with trace elements supports primary cell viability and stem cell maintenance in low-serum conditions.

Primary cellsMSCsiPSC co-culture
Metabolomics

Metabolic Flux Analysis

Defined, phosphate-buffered nutrient base supports 13C isotope tracing and other metabolic flux workflows. Not compatible with Agilent Seahorse XF assays, which require bicarbonate-free, phenol red-free medium.

13C tracingMetabolomics
Live-Cell Imaging

Microscopy & Optical Sensing

Ultra-low particulate baseline supports confocal microscopy, TEER measurement, and biosensor-based assays; phenol-red-free variants available on request.

ConfocalTEERBiosensors
Technical Specifications

Analytical release specifications

Every lot released against the full specification matrix. CoA: support@diagnocine.com.

Physical & Chemical Parameters
Parameter Specification
Formulation [+] Glucose, [+] L-Glutamine, [+] Phenol Red, [+] Calcium, [+] Magnesium | [-] Sodium Bicarbonate
Appearance Red-colored, clear solution
Glucose 5000 mg/L (5.0 g/L)
L-Glutamine 350 mg/L
Phenol Red 11 mg/L (phenol red sodium salt)
pH USP <791> 7.4
Osmolality USP <785> 240 – 345 mOsm/kg H2O
Total ingredients 40 (across 4 categories)
Sterility, Purity & Safety Parameters
Parameter Specification
Endotoxin USP <85> BET < 0.05 EU/mL
Sterility USP <71> No growth / 14 days
Mycoplasma 0.1 µm mycoplasma-retentive filtration (not tested per lot)
Particulate ≥10 µm USP <788> Method 1 NMT 25/mL
Particulate ≥25 µm USP <788> Method 1 NMT 3/mL
Water purity Type 1, 18.2 MΩ·cm
Manufacturing std. ISO 13485:2016
Fill environment ISO Class 5 (Class 100)
Storage, Handling & Logistics
Parameter Specification
Storage temperature 2–8°C, away from light
Freeze-thaw Do not freeze
Shelf life 12 months from date of manufacture, unopened
Shipping condition Cold pack
CO₂ requirement CO₂-independent; phosphate-buffered; supplement with HEPES (15–25 mM) for additional pH buffering if required
Raw Materials & Regulatory Traceability
Parameter Specification
Raw material grade Reagent / cell culture grade
Traceability Full lot traceability per ISO 13485
Manufacturing QMS ISO ISO 13485:2016 certified
UNSPSC 41116155 — Molecular biology and cell culture growth media (UNv260801)
Regulatory alignment 21 CFR Part 820 (QMSR) aligned
Production method Micro-batch, per-lot QC release
Intended use Research Use Only (RUO)
Formulation

Full composition (mg/L)

Waymouth Medium MB 752/1 (w/o sodium bicarbonate): 40 ingredients verified per lot with CAS numbers for full raw-material traceability.

Component CAS Number mg/L
INORGANIC SALTS
Calcium chloride dihydrate 10035-04-8 120.000
Disodium hydrogen phosphate anhydrous 7558-79-4 300.000
Magnesium chloride anhydrous 7786-30-3 112.560
Magnesium sulfate anhydrous 7487-88-9 97.720
Potassium chloride 7447-40-7 150.000
Potassium dihydrogen phosphate 7778-77-0 80.000
Sodium chloride 7647-14-5 6000.000
Component CAS Number mg/L
AMINO ACIDS
Glycine 56-40-6 50.000
L-Arginine hydrochloride 1119-34-2 75.000
L-Aspartic acid 56-84-8 60.000
L-Cysteine hydrochloride monohydrate 7048-04-6 90.000
L-Cystine dihydrochloride 30925-07-6 19.550
L-Glutamic acid 56-86-0 150.000
L-Glutamine 56-85-9 350.000
L-Histidine hydrochloride monohydrate 5934-29-2 150.000
L-Isoleucine 73-32-5 25.000
L-Leucine 61-90-5 50.000
L-Lysine hydrochloride 657-27-2 240.000
L-Methionine 63-68-3 50.000
L-Phenylalanine 63-91-2 50.000
L-Proline 147-85-3 50.000
L-Threonine 72-19-5 75.000
L-Tryptophan 73-22-3 40.000
L-Tyrosine disodium salt dihydrate 69847-45-6 57.660
L-Valine 72-18-4 65.000
Component CAS Number mg/L
VITAMINS
Ascorbic acid 50-81-7 17.500
Biotin 58-85-5 0.020
Choline chloride 67-48-1 250.000
D-Ca-Pantothenate 137-08-6 1.000
Folic acid 59-30-3 0.400
Niacinamide 98-92-0 1.000
Pyridoxine hydrochloride 58-56-0 1.000
Riboflavin 83-88-5 1.000
Thiamine hydrochloride 67-03-8 10.000
Vitamin B12 68-19-9 0.200
i-Inositol 87-89-8 1.000
Hypoxanthine sodium salt   29.000
OTHERS
D-Glucose 50-99-7 5000.000
Glutathione reduced 70-18-8 15.000
Phenol red sodium salt 34487-61-1 11.000
Custom formulation: Contact support@diagnocine.com for DCP-WMBM-B1X modifications.
Quality Assurance

Manufacturing & compliance

Every FluxMPS™ product is manufactured and released under a multi-layer quality system.

verified

ISO 13485:2016 Quality Management

Manufactured under an ISO 13485:2016-certified quality management system. Final QC at the Diagnocine R&D Center, Totowa, NJ, USA.

water_drop

Ultrapure Type 1 Water

18.2 MΩ·cm with trace-metal and organic-carbon (TOC) control.

biotech

ISO Class 5 Fill & Finish

Aseptic fill in validated ISO Class 5 (Class 100) laminar-flow workstations.

assignment

Micro-Batch Precision

Small-batch, per-lot tested — Certificate of Analysis issued for every batch.

Endotoxin — USP <85> BET

LAL assay; release specification < 0.05 EU/mL per manufacturing batch.

Particulate — USP <788> Method 1

NMT 25/mL (≥10 µm), NMT 3/mL (≥25 µm); light-obscuration method.

Osmolality — USP <785>

Target: 240 – 345 mOsm/kg H2O.

Documentation & CoA

Full CoA with raw-material traceability available on request.

Batch-level quality control. Endotoxin is controlled per manufacturing batch rather than per unit. Every batch is tested before release and must meet the release specification:
  • Endotoxin — LAL assay, USP <85> Bacterial Endotoxins Test; assay sensitivity 0.005 EU/mL; release specification < 0.05 EU/mL
  • pH, osmolality, conductivity, appearance and clarity
  • Sterility
A Certificate of Analysis is available on request at support@diagnocine.com.
Product Comparison

How DCP-WMBM-B1X compares

FluxMPS™ DCP-WMBM-B1X vs. conventional 0.22 µm–filtered Waymouth formulations and standard DMEM/RPMI media.

Parameter DCP-WMBM-B1X (FluxMPS™) Conventional Waymouth Medium
(0.22 µm filtered)
Standard DMEM/RPMI
(0.22 µm filtered)
Grade Microfluidics Suitable Not specified Not specified
Waymouth MB 752/1 without sodium bicarbonate — CO₂-independent hybridoma and fibroblast culture check_circle Yes cancel No cancel No
Final filtration pore size 0.04 µm 0.22 µm 0.22 µm
Number of filtration stages 4 (Quadruple) 1 1
Mycoplasma-retentive filtration check_circle Yes (0.1 µm + 0.04 µm stages) cancel No cancel No
Endotoxin (release specification) FluxMPS™ — < 0.05 EU/mL Corning classical liquid media — < 0.25 EU/mL
Sigma-Aldrich DMEM complete medium — ≤ 2 EU/mL
Gibco classical DMEM — Not specified (recorded per lot)
USP <788> Method 1 particulate tested check_circle Yes cancel No cancel No
Water quality Type 1, 18.2 MΩ·cm Purified water Purified water
Manufacturing QMS ISO 13485:2016 ISO 9001 or none ISO 9001 or none
Microfluidic channel compatibility check_circle Microfluidics Suitable cancel Risk of clogging cancel Risk of clogging
Custom formulation available check_circle Yes cancel No cancel No

Comparison figures from published supplier specifications, accessed 2026-09-02. Suppliers that publish no numeric endotoxin specification are shown as "Not specified".

FAQ

Frequently asked questions

Common questions about FluxMPS™ DCP-WMBM-B1X — Waymouth Medium MB 752/1 without sodium bicarbonate.

Yes. DCP-WMBM-B1X is processed through a Quadruple-stage filtration system reaching a 0.04 µm final pore size, making it Microfluidics Suitable for organ-on-a-chip (OoC), tissue-on-a-chip (ToC), and other microphysiological system (MPS) platforms culturing hybridomas, fibroblasts, and other mammalian cell lines.
FluxMPS™ runs two 0.1 µm prefilter + 0.04 µm final-filter pairs in series — Prefiltration I, Final filtration I, Prefiltration II, Final filtration II — reaching a 0.04 µm final cut-off, five times finer than the 0.22 µm membranes used in conventional sterile filtration.
Sodium bicarbonate is excluded so this formulation can be used in CO₂-independent (ambient air) conditions, relying on its phosphate buffering system. If additional buffering capacity is needed — for example in open-top chips or long perfusion runs — supplement with HEPES (15–25 mM), which is not included in this formulation. Contact support@diagnocine.com for a HEPES-supplemented variant.
No. This formulation is CO₂-independent and phosphate-buffered, suitable for ambient-air incubation. Supplement with HEPES (15–25 mM) for additional pH buffering if the culture format requires it.
Yes. Add FBS, serum-free supplements, growth factors, or antibiotics as required. When adding serum or protein-containing supplements, use a 0.2 µm low-protein-binding PES or PVDF filter rather than a 0.04 µm membrane, which will retain serum proteins and lipoproteins. Contact support@diagnocine.com for custom co-formulation.
Endotoxin is controlled per manufacturing batch, not per unit. Every batch is tested by LAL assay (USP <85>, assay sensitivity 0.005 EU/mL) and must meet a release specification of < 0.05 EU/mL before release. A Certificate of Analysis is available on request.
Yes. Full CoA per batch covers: appearance, pH (USP <791>), osmolality (USP <785>), sterility (USP <71>), endotoxin (USP <85>), particulate count (USP <788> Method 1), and raw-material traceability. Request at support@diagnocine.com.
Scientific References

Supporting literature

Key publications supporting Waymouth Medium MB 752/1 in specialized cell culture and OoC applications.

  1. Waymouth C. Rapid proliferation of sublines of NCTC clone 929 (strain L) mouse cells in a simple chemically defined medium (MB 752/1). J Natl Cancer Inst. 1959;22:1003–1017. doi:10.1093/jnci/22.5.1003
  2. Huh D, et al. Reconstituting organ-level lung functions on a chip. Science. 2010;328:1662–1668. doi:10.1126/science.1188302
  3. Bhatia SN, Ingber DE. Microfluidic organs-on-chips. Nat Biotechnol. 2014;32:760–772. doi:10.1038/nbt.2989
  4. Novak R, et al. Robotic fluidic coupling and interrogation of multiple vascularized organ chips. Nat Biomed Eng. 2020;4:407–420. doi:10.1038/s41551-019-0497-x
  5. Jang KJ, et al. Human kidney proximal tubule-on-a-chip. Integr Biol. 2013;5:1119–1129. doi:10.1039/c3ib40049b
  6. Schimek K, et al. Integrating biological vasculature into a multi-organ-chip microsystem. Lab Chip. 2013;13:3588–3598. doi:10.1039/c3lc50217a
  7. Luni C, et al. High-efficiency cellular reprogramming with microfluidics. Nat Methods. 2016;13:446–452. doi:10.1038/nmeth.3832
  8. Sung JH, et al. Microfabricated mammalian organ systems. Lab Chip. 2013;13:1201–1212. doi:10.1039/c3lc41017j

Satisfaction
Quality Rating
Value Rating
Style Rating
X