ReverTra Ace® qPCR RT Master Mix with gDNA Remover, Trial (Only 1 Per Customer)

Product#: TYB-FSQ-301S
$1.00
Availability:
Ships in 24 hours

TOYOBO · Diagnocine

ReverTra Ace® qPCR RT Master Mix with gDNA Remover, Trial (Only 1 Per Customer)

ReverTra Ace® qPCR RT Master Mix with gDNA Remover (*Only 1 Per Customer*) Cat.No. FSQ-301 Storage-20C Size400 µl for 200 (10 µl) reactions Price per reaction $2.37DescriptionThis kit includes reagents for reverse transcription and for the…

Cat No.
TYB-FSQ-301S
UNSPSC Code
12352204
Packaging
Trial Sample
Storage Temp.
Store at -20ºC  | Ships on Dry Ice

Shipping & ordering notice: This product has ICE or DRY ICE shipping requirements, DO NOT select Ground Shipping. $1.00 is only for sample (please inquire)

Product Overview

ReverTra Ace® qPCR RT Master Mix with gDNA Remover (*Only 1 Per Customer*)

Description
This kit includes reagents for reverse transcription and for the removal of genomic DNA [DNase I treatment].
In many cases, total RNA prepared using spin-columns or acid guanidium-phenolchloroform (AGPC) extraction methods contains small amounts of genomic DNA. Any contaminating genomic DNA will be amplified along with cDNA, especially when primer pairs are designed within the same exon or from pseudogenes. Amplification from genomic DNA can result in qualitative and quantitative inaccuracies. This kit aids in the removal of genomic DNA in order to reduce such inaccuracies.
The protocol consists of (i) a genomic DNA degradation step using "gDNA remover" and (ii) a reverse transcription step. The two steps can be achieved sequentially without purification or heat inactivation of DNase I.
FSQ-301_compare.png* For this comparison all reactions are using a volume of 20µl (up to 1µg) *
  
Features

  • "Genomic DNA degradation step" and "cDNA synthesis step" can be achieved sequentially in approximately 30 min.
  • The master mix reagent contains random and oligo dT primers optimized for efficient reverse transcription.
  • Control, no reverse transcription experiments (no RT-control) can be performed with 5x RT Master Mix II no-RT control.
  • Suitable for the detection of low abundance mRNAs
  FSQ-301_features.png

Applications

  • cDNA synthesis for real-time PCR

Components

gDNA Remover 10 µl
4x DN Master Mix 440 µl
5x RT Master Mix II 400 µl
5x RT Master Mix II no RT-Control 40 µl
Nuclease-free water 1000 µl × 2


Application data
 

Example.Efficiency of genomic DNA removal
In experiment 1, reverse transcription was performed according to the following condition and Table 1. Then β-actin genes were detected by SYBR® Green I assay. No signal for the "C experiment" indicates that contaminating genomic DNA in the RNA template was completely removed by "gDNA remover".

4x DN Master Mix 5x RT Master Mix
A gDNA Remover(-) RTase(-)
BgDNA Remover(-) RTase(+)
CgDNA Remover(+) RTase(-)
DgDNA Remover(+) Rtase(+)
FSQ-301_example1.pngIn experiment 1, reverse transcription was performed according to the following condition and Table 1. Then β-actin genes were detected by SYBR® Green I assay. No signal for the "C experiment" indicates that contaminating genomic DNA in the RNA template was completely removed by "gDNA remover".
FSQ-301_example2.png

Template RNA
Experiment 1: HeLa total RNA 0.5 µg / 10 µl reaction
Experiment 2: HeLa total RNA (0, 1 pg, 10 pg, 100 pg, 1 ng, 10 ng, 100 ng, 1 µg) + human gDNA 100 ng / 20 µl reaction

Real-time PCR
Reagent: THUNDERBIRD® SYBR® qPCR Mix (Code No. QPS-201)
Template: cDNA 2 µl / 20 µl reaction (cDNA solution: 10 %)
Target: β-actin (188 bp)
Real-time cycler: Applied Biosystems 7900HT

Cat No. List & Ordering
Product Name Cat. No. Storage Link Order
ReverTra Ace® qPCR RT Master Mix with gDNA Remover, Trial TYB-FSQ-301S Store at -20°C   Current page
ReverTra Ace® qPCR RT Master Mix with gDNA Remover, 200 rxn TYB-FSQ-301 Store at -20°C   Order

Satisfaction
Quality Rating
Value Rating
Style Rating
X