FluxMPS™ Minimum Essential Medium (MEM), High Glucose & 25mM HEPES w/o L-Glutamine, Sodium Pyruvate: 1X Liquid

Product#: DCP-MEMGH-QPN1X
$44.00
DCP-MEMGH-QPN1X
Availability:
Ships in 1-2 Weeks

warning For Research Use Only (RUO). Not intended for clinical, diagnostic, or therapeutic use in humans.
ISO 13485 Certified Manufacturing

FluxMPS™ Minimum Essential Medium (MEM), High Glucose & 25mM HEPES w/o L-Glutamine, Sodium Pyruvate: 1X Liquid

Contains Sodium Bicarbonate Contains Phenol Red Contains HEPES Contains Calcium Contains Magnesium Contains Glucose Without L-Glutamine Without Sodium Pyruvate

FluxMPS™ Minimum Essential Medium (MEM), High Glucose & 25mM HEPES w/o L-Glutamine, Sodium Pyruvate: 1X Liquid is a Microfluidics Suitable, Quadruple-stage ultra-filtered (0.1 µm ×2 + 0.04 µm ×2) cell culture medium engineered for organ-on-a-chip (OoC), tissue-on-a-chip (ToC), and microphysiological system (MPS) applications. A quadruple-stage train (0.1 µm ×2 + 0.04 µm ×2) reaches a 0.04 µm final cut-off, five times finer than the 0.22 µm membranes used for conventional sterile filtration.

  • High-glucose (4.5 g/L) Minimum Essential Medium (MEM) base with 25 mM HEPES buffering and the standard Eagle's MEM essential amino acid profile — formulated without L-glutamine or sodium pyruvate for full metabolic control
  • Quadruple-stage nano-filtration: two dedicated 0.1 µm prefilter passes paired with two 0.04 µm final filter passes (0.1 µm ×2 + 0.04 µm ×2)
  • Endotoxin release specification: less than 0.05 EU/mL, controlled per manufacturing batch by LAL assay (USP <85> Bacterial Endotoxins Test)
  • pH 7.4 (USP <791>); osmolality documented per lot on the Certificate of Analysis (USP <785>)
  • Contains sodium bicarbonate (2200 mg/L) alongside 25 mM HEPES — compatible with standard CO₂ incubation, with HEPES providing added bench stability
  • Manufactured under an ISO 13485:2016 quality management system with aseptic fill and finish
  • Custom formulations available — pH, glucose, salts, HEPES, and nutrient composition on request
DCP-MEMGH-QPN1X | Cell Culture Media
UNSPSC: 41116155 | Commodity: Molecular biology and cell culture growth media | (UNv260801)
Minimum Essential Medium (MEM), High Glucose & 25mM HEPES w/o L-Glutamine, Sodium Pyruvate: 1X Liquid
  • Glucose4500 mg/L (4.5 g/L)
  • L-GlutamineNot present — supplement as needed
  • Sodium PyruvateNot present — supplement as needed
  • HEPES5958 mg/L (25 mM)
  • Sodium Bicarbonate2200 mg/L
  • pH (USP <791>)7.4
  • Osmolality (USP <785>)See Certificate of Analysis
  • Endotoxin (USP <85>)< 0.05 EU/mL
  • Filtration0.1 µm ×2 + 0.04 µm ×2 (Quadruple-stage)
  • Shelf Life12 months from date of manufacture, unopened
ISO 13485:2016 USP <85> <785> <788> RUO
Why FluxMPS™

Engineered where standard media fails

Conventional 0.22 µm-filtered media carry mycoplasma-sized particulates (0.2–0.3 µm), subvisible debris, and endotoxin variability that accumulate inside microchannels — corrupting biosensor readings and shortening device lifetimes. FluxMPS™ is built to address these failure modes at the filtration stage.

filter_alt

Microchannel-safe purity

0.04 µm final filter retains particles to sub-mycoplasma size; USP <788> Method 1 (light obscuration) particulate compliance verified per lot.

target

High-glucose metabolic support

4.5 g/L glucose supports high-energy-demand cell types including HeLa, MCF-7, fibroblasts, and iPSC-derived models in perfusion devices.

water_drop

Ultrapure-grade water

Prepared with Type 1 ultrapure water (18.2 MΩ·cm) under trace-metal and total organic carbon (TOC) control, supporting reproducible formulation lot to lot.

visibility

Low background for imaging

Ultra-low particulate formulation supports confocal microscopy, live-cell biosensors, and TEER measurements by minimizing particulate interference.

science

Rich, stable nutrient profile

Complete Eagle's MEM essential amino acid profile plus micro-batch precision manufacturing ensures comprehensive amino acid coverage for demanding cell culture models.

tune

Customization on demand

pH, glucose, salts, HEPES, and full nutrient composition available on request. Contact support@diagnocine.com.

Purity Architecture

Quadruple-stage filtration system

FluxMPS™ Minimum Essential Medium (MEM), High Glucose & 25mM HEPES w/o L-Glutamine, Sodium Pyruvate: 1X Liquid is processed through a four-stage serial filtration train — two dedicated 0.1 µm prefilter passes, each paired with its own 0.04 µm final filter — reaching a 0.04 µm final cut-off that addresses mycoplasma-scale and subvisible particulates that 0.22 µm filtration cannot.

  1. 1

    0.1 µm Prefiltration I

    Removes large particulates, cell debris and protein aggregates; protects the first 0.04 µm final filter cartridge.

  2. 2

    0.04 µm Final filtration I

    First 0.04 µm pass; retains sub-micron particulates and microaggregates that pass a 0.22 µm filter.

  3. 3

    0.1 µm Prefiltration II

    Second dedicated prefilter pass, protecting the second 0.04 µm final filter cartridge and providing full-train redundancy.

  4. 4

    0.04 µm Final filtration II — Polish

    Ultimate polishing filter; aseptic fill & finish performed under ISO 13485:2016-controlled conditions.

Performance vs. conventional media

Four sequential stages reaching a 0.04 µm final cut-off deliver approximately 5× cleaner media by particulate count compared to single-pass 0.22 µm filtration.

5×
 
0.04
µm final filter pore size across 4 sterile passes
Sterility assurance: Every lot undergoes 14-day USP <71> sterility testing. Mycoplasma risk is controlled via 0.1 µm mycoplasma-retentive prefiltration (not tested per lot); no bacterial or fungal growth observed in validation studies.
Grade: This product is Microfluidics Suitable, filtered to a 0.04 µm final cut-off. It is not an MPS Grade product — that designation is reserved for the 0.01 µm ultra nano-filtered line, which adds 0.02 µm and 0.01 µm stages after the 0.04 µm polish. For applications requiring the 0.01 µm cut-off, contact support@diagnocine.com.
FluxMPS™ Minimum Essential Medium (MEM), High Glucose & 25mM HEPES w/o L-Glutamine, Sodium Pyruvate: 1X Liquid (DCP-MEMGH-QPN1X) Quadruple-stage filtration system: 0.1 micron Prefiltration I, 0.04 micron Final filtration I, 0.1 micron Prefiltration II, 0.04 micron Final filtration II Polish, Microfluidics Suitable for organ-on-a-chip and microfluidic applications by Diagnocine
Figure 1. FluxMPS™ Quadruple-stage filtration architecture (0.1 µm ×2 + 0.04 µm ×2) delivering Microfluidics Suitable purity for MPS and OoC applications.
© Diagnocine® — DCP-MEMGH-QPN1X
Applications

Designed for next-generation cell culture platforms

FluxMPS™ Minimum Essential Medium (MEM), High Glucose & 25mM HEPES w/o L-Glutamine, Sodium Pyruvate: 1X Liquid is validated for organ-on-a-chip, cancer biology, stem cell, vascular, metabolic and live-cell imaging applications where particulate contamination and endotoxin variation are unacceptable.

Automated Bioreactors & Robotics

Next-Generation System Uptime

An optional 0.01 µm (10 nm) MPS Grade variant is available for automated bioreactor and robotic perfusion systems requiring the ultimate particulate exclusion — a separate tier from the Microfluidics Suitable (0.04 µm) grade of this product.

  • Total Particulate Exclusion: 10 nm filtration for nanoscale valve and sensor protection
  • Valve & Sensor Protection: prevents particulate-induced blockage in precision fluidic systems
  • Extended Perfusion Stability: maintains flow rate consistency across multi-week automated runs

Inquiry Required: Contact support@diagnocine.com to request the 0.01 µm MPS Grade variant.

Microfluidics

Micro Physiological System (MPS) & Chip

Quadruple-stage filtered formulation prevents microchannel clogging and maintains laminar flow integrity across complex chip geometries.

OoCToCBoCLoCMPS
Cancer Biology

Warburg Effect & Metabolic Research

High-glucose base supports Warburg effect studies and glucose uptake assays in cancer cell lines.

MCF-7MDA-MB-231HeLaHT-1080
Stem Cell Biology

iPSC-Derived Models

Ultra-filtered formulation supports sensitive iPSC differentiation protocols where endotoxin variability causes off-target effects.

iPSC-NeuronsiPSC-CMiPSC-Hep
Vascular Biology

Endothelial & Primary Cells

Microchannel-safe purity supports endothelial barrier integrity and TEER stability in perfusion models.

HUVECsBHK-21Primary fibroblasts
Metabolomics

Metabolic Flux Analysis

High-glucose base enables precise ¹³C isotope tracing and glycolytic flux experiments. Not compatible with Agilent Seahorse XF assays, which require bicarbonate-free, phenol red-free medium.

13C tracingNMR metabolomics
Live-Cell Imaging

Microscopy & Optical Sensing

Ultra-low particulate load ideal for high-content confocal imaging and optical biosensor integration, minimizing particulate background.

ConfocalBiosensorsTEER
Technical Specifications

Lot-release quality parameters

Every production lot of FluxMPS™ Minimum Essential Medium (MEM), High Glucose & 25mM HEPES w/o L-Glutamine, Sodium Pyruvate: 1X Liquid undergoes the complete quality-release battery below before shipment.

Physical & Chemical Parameters
Parameter Specification
Formulation Sodium bicarbonate, phenol red, HEPES, calcium and magnesium present; without L-glutamine and sodium pyruvate
Appearance Orange-to-red colored, clear solution
pH USP <791> 7.4
Osmolality USP <785> See Certificate of Analysis
Glucose 4500 mg/L (4.5 g/L)
L-Glutamine Not present — supplement as needed
Sodium Pyruvate Not present — supplement as needed
Phenol Red 11 mg/L (present)
Sterility, Purity & Safety Parameters
Parameter Specification
Endotoxin USP <85> BET < 0.05 EU/mL (batch release specification)
Sterility USP <71> No growth after 14 days
Mycoplasma 0.1 µm mycoplasma-retentive filtration (not tested per lot)
Particulate ≥10 µm USP <788> Method 1 Compliant
Particulate ≥25 µm USP <788> Method 1 Compliant
Water Purity Ultrapure Type 1 water (18.2 MΩ·cm)
Manufacturing std. ISO 13485 ISO 13485:2016
Fill environment ISO Class 5 (Class 100) aseptic fill
Storage, Handling & Logistics
Parameter Specification
Storage temperature 2–8°C, protected from light
Freeze-thaw Not recommended
Shelf life 12 months from date of manufacture, unopened
Shipping condition Cold pack
CO₂ requirement ~5% CO₂ recommended (calculated from 2200 mg/L NaHCO₃); 25 mM HEPES provides added bench stability outside the incubator
Raw Materials & Regulatory Traceability
Parameter Specification
Raw material grade Cell culture / reagent grade
Traceability Full lot documentation, CoA available
Manufacturing QMS ISO 13485:2016 certified
UNSPSC 41116155 — Molecular biology and cell culture growth media (UNv260801)
Regulatory alignment 21 CFR Part 820 (QMSR) aligned
Production method Micro-batch precision manufacturing
Intended use For Research Use Only (RUO)
Formulation

Full composition (mg/L)

Complete formulation with CAS numbers, reproduced from manufacturer specification. Total: 29 components across 4 categories. Custom compositions available on request.

Component CAS Number mg/L
INORGANIC SALTS
Calcium chloride dihydrate 10035-04-8 265.000
Magnesium sulfate anhydrous 7487-88-9 97.720
Potassium chloride 7447-40-7 400.000
Sodium bicarbonate 144-55-8 2200.000
Sodium chloride 7647-14-5 6800.00
Sodium phosphate dibasic anhydrous 7558-79-4 122.000
Component CAS Number mg/L
AMINO ACIDS
L-Arginine hydrochloride 1119-34-2 126.000
L-Cystine dihydrochloride 30189-89-0 31.300
L-Histidine hydrochloride monohydrate 5934-29-2 42.000
L-Isoleucine 73-32-5 52.000
L-Leucine 61-90-5 52.000
L-Lysine hydrochloride 657-27-2 72.500
L-Methionine 63-68-3 15.000
L-Phenylalanine 63-91-2 32.000
L-Threonine 72-19-5 48.000
L-Tryptophan 73-22-3 10.000
L-Tyrosine disodium salt 69847-45-6 51.900
L-Valine 72-18-4 46.000
Component CAS Number mg/L
VITAMINS
Choline chloride 67-48-1 1.000
D-Ca-Pantothenate 137-08-6 1.000
Folic acid 59-30-3 1.000
Niacinamide 98-92-0 1.000
Pyridoxine hydrochloride 58-56-0 1.000
Riboflavin 83-88-5 0.100
Thiamine hydrochloride 67-03-8 1.000
OTHERS
i-Inositol 87-89-8 2.000
D-Glucose 50-99-7 4500.000
HEPES 7365-45-9 5958.000
Phenol red sodium salt 34487-61-1 11.000
Customization: pH, glucose, salt balance, HEPES, and full nutrient profile available on request. Contact support@diagnocine.com.
Quality Assurance

ISO 13485:2016 manufacturing & compliance

Manufactured under ISO 13485:2016 QMS with final packaging, testing, and customization at Diagnocine Precision in Totowa, New Jersey, USA.

verified

ISO 13485:2016 QMS

Full quality management system certification covering manufacturing, testing, and release for every production lot.

water_drop

Ultrapure Type 1 Water

All media prepared with 18.2 MΩ·cm resistivity water under trace-metal and TOC control.

biotech

ISO Class 5 Fill & Finish

Aseptic filling in validated ISO Class 5 laminar-flow workstations; 21 CFR Part 820 (QMSR) aligned.

assignment

Micro-Batch Precision

Small-batch manufacturing ensures lot-to-lot nutrient consistency for reproducible perfusion studies.

Endotoxin — USP <85> BET

LAL assay per batch; release specification < 0.05 EU/mL; assay sensitivity 0.005 EU/mL.

Particulate — USP <788> Method 1

Light obscuration particle count confirms ≥10 µm and ≥25 µm compliance per lot.

Osmolality — USP <785>

Freezing-point osmometry per USP <785>. Result documented per lot on the CoA.

Documentation — CoA & Full Lot Records

Certificate of Analysis with full QC panel, traceability, and release signatures for every lot.

Batch-level quality control. Endotoxin is controlled per manufacturing batch rather than per unit. Every batch is tested before release and must meet the release specification:
  • Endotoxin — LAL assay, USP <85> Bacterial Endotoxins Test; assay sensitivity 0.005 EU/mL; release specification < 0.05 EU/mL
  • pH, osmolality, conductivity, appearance and clarity
  • Sterility
A Certificate of Analysis is available on request via support@diagnocine.com.
Product Comparison

How DCP-MEMGH-QPN1X (FluxMPS™) compares

Side-by-side comparison against conventional 0.22 µm-filtered MEM High Glucose alternatives and published supplier endotoxin specifications.

Parameter DCP-MEMGH-QPN1X (FluxMPS™) Conventional MEM High Glucose (0.22 µm) Standard MEM High Glucose alternative
Grade Microfluidics Suitable (0.04 µm final) Not applicable (0.22 µm filtered, ungraded) Not applicable
Base Formulation MEM High Glucose & 25mM HEPES w/o L-Glutamine, Sodium Pyruvate MEM High Glucose Standard MEM High Glucose Equivalent
Final filtration pore size 0.04 µm 0.22 µm 0.22 µm
Number of filtration stages 4 stages 1 stage 1–2 stages
Mycoplasma barrier filtration check_circle cancel cancel
Endotoxin (release specification) FluxMPS™ — < 0.05 EU/mL Corning classical liquid media — < 0.25 EU/mL
Sigma-Aldrich DMEM complete medium — ≤ 2 EU/mL
Gibco classical DMEM — Not specified (recorded per lot)
USP particulate compliance check_circle USP <788> Method 1 cancel cancel
Water quality Ultrapure Type 1 (18.2 MΩ·cm) Purified water Purified water
Manufacturing QMS ISO 13485:2016 Variable Variable
Microfluidic channel compatibility check_circle Validated cancel Risk of clogging cancel Risk of clogging
Custom formulation check_circle On request cancel Limited

Comparison figures from published supplier specifications, accessed 2026-09-02. Suppliers that publish no numeric endotoxin specification are shown as "Not specified".

FAQ

Frequently asked questions

Common questions about FluxMPS™ Minimum Essential Medium (MEM), High Glucose & 25mM HEPES w/o L-Glutamine, Sodium Pyruvate: 1X Liquid and Microfluidics Suitable cell culture media.

Yes. DCP-MEMGH-QPN1X uses our Quadruple-stage filtration (0.1 µm ×2 + 0.04 µm ×2), delivering low particulate counts that reduce the risk of microchannel clogging in OoC and MPS devices. It is Microfluidics Suitable, filtered to a 0.04 µm final cut-off.
Standard 0.22 µm filtration leaves intact mycoplasma-sized particulates (0.2–0.3 µm) and subvisible debris that accumulate in microchannels. FluxMPS™ uses four sequential stages reaching 0.04 µm, delivering approximately 5× lower particulate counts per USP <788> Method 1 (light obscuration).
This base formulation ships without L-glutamine or sodium pyruvate so you can set exact concentrations for your assay. Add L-glutamine to 2–4 mM (or a stabilized dipeptide substitute) and sodium pyruvate to 1 mM final concentration immediately before use, per your protocol. Contact support@diagnocine.com for a custom pre-supplemented formulation.
This formulation contains sodium bicarbonate (2200 mg/L) alongside 25 mM HEPES buffering. Approximately 5% CO₂ is recommended for standard incubation; the HEPES component adds pH stability during bench manipulations outside the incubator.
Yes. FluxMPS™ Minimum Essential Medium (MEM), High Glucose & 25mM HEPES w/o L-Glutamine, Sodium Pyruvate: 1X Liquid can be supplemented with FBS (5–20%), growth factors, antibiotics, or other additives per standard practice. Filter serum-containing and protein-based additions through a 0.2 µm low-protein-binding PES or PVDF membrane before adding; do not use a 0.04 µm membrane for supplements, as it retains serum proteins and lipoproteins. Add supplements immediately before use.
Endotoxin is controlled per manufacturing batch, not per unit. Every batch is tested by LAL assay per USP <85> Bacterial Endotoxins Test (assay sensitivity 0.005 EU/mL) and must meet the release specification of < 0.05 EU/mL before release. Lot-specific results are documented in the Certificate of Analysis, available from support@diagnocine.com.
Yes. A lot-specific CoA is available for every shipment and includes: appearance, pH (USP <791>), osmolality (USP <785>), endotoxin (USP <85> BET), sterility (USP <71>), particulate matter (USP <788> Method 1), raw material traceability, manufacturing date, expiry, and authorized release signatures. Request via support@diagnocine.com.
Scientific References

Supporting literature

Peer-reviewed publications supporting Microfluidics Suitable ultra-filtered media and microfluidic cell culture applications.

  1. Huh D et al. (2010). Reconstituting organ-level lung functions on a chip. Science, 328(5986), 1662–1668. doi:10.1126/science.1188302
  2. Bhatia SN & Ingber DE (2014). Microfluidic organs-on-chips. Nature Biotechnology, 32(8), 760–772. doi:10.1038/nbt.2989
  3. Eagle H (1959). Amino acid metabolism in mammalian cell cultures. Science, 130(3373), 432–437. doi:10.1126/science.130.3373.432
  4. Warburg O (1956). On the origin of cancer cells. Science, 123(3191), 309–314. doi:10.1126/science.123.3191.309
  5. Bhattacharya S et al. (2018). Challenges in maintaining cell viability during microfluidic experiments. Electrophoresis, 39(7), 997–1006. doi:10.1002/elps.201700375
  6. Zhang YS et al. (2017). Multisensor-integrated organs-on-chips for automated in situ monitoring. PNAS, 114(12), E2293–E2302. doi:10.1073/pnas.1612906114
  7. Vernetti L et al. (2017). Functional coupling of human microphysiology systems. Scientific Reports, 7, 42296. doi:10.1038/srep42296
  8. Esch EW et al. (2015). Organs-on-chips at the frontiers of drug discovery. Nature Reviews Drug Discovery, 14(4), 248–260. doi:10.1038/nrd4539
  9. Zheng F et al. (2021). Organ-on-a-chip systems: microengineering to biomimic living systems. Small, 17(7), 2004175. doi:10.1002/smll.202004175

Satisfaction
Quality Rating
Value Rating
Style Rating
X