FluxMPS™ Dulbecco’s Modified Eagle Medium (DMEM), High Glucose w/o Phenol Red: 1X Liquid

Product#: DCP-DMEM-R1X
$44.00
DCP-DMEM-R1X
Availability:
Ships in 1-2 Weeks

warning For Research Use Only (RUO). Not intended for clinical, diagnostic, or therapeutic use in humans.
verified ISO 13485 Certified Manufacturing

FluxMPS™ Dulbecco’s Modified Eagle Medium (DMEM), High Glucose w/o Phenol Red: 1X Liquid

Contains L-Glutamine Contains Sodium Bicarbonate Contains Calcium Contains Magnesium Contains High Glucose (4500 mg/L) Contains Sodium Pyruvate Without Phenol Red

FluxMPS™ DCP-DMEM-R1X is a Microfluidics Suitable, quadruple-stage ultra-filtered (0.1 µm ×2 + 0.04 µm ×2) DMEM High Glucose (4.5 g/L) formulation engineered for organ-on-a-chip (OoC), microphysiological systems (MPS), and energy-demanding cell models. The train reaches a 0.04 µm final cut-off — five times finer than the 0.22 µm membranes used for conventional sterile filtration. Formulation: [+] L-Glutamine, [+] Sodium Bicarbonate, [+] Calcium, [+] Magnesium, [+] High Glucose (4500 mg/L), [+] Sodium Pyruvate | [-] Phenol Red.

  • High Glucose (4.5 g/L) — supports energy-demanding cell types: primary neurons, cardiomyocytes, cancer lines
  • Quadruple-stage filtration train (0.1 µm ×2 + 0.04 µm ×2) reaching a 0.04 µm final cut-off — five times finer than standard 0.22 µm sterile filtration
  • Endotoxin release specification: < 0.05 EU/mL (LAL, USP <85>)
  • Bicarbonate-buffered (3700 mg/L NaHCO3); requires approximately 10% CO2 atmosphere to maintain pH 7.4
  • Formulation: [+] L-Glutamine, [+] Sodium Bicarbonate, [+] Calcium, [+] Magnesium, [+] High Glucose (4500 mg/L), [+] Sodium Pyruvate | [-] Phenol Red
  • Manufactured under an ISO 13485:2016 quality management system; Ultrapure Type 1 water (18.2 MΩ·cm) and ISO Class 5 aseptic fill
  • Custom pH, salts, glucose concentration, and nutrient adjustments available on request
CAT. NO.
DCP-DMEM-R1X | Cell Culture Media UNSPSC: 41116155 | Commodity: Molecular biology and cell culture growth media | (UNv260801)
Dulbecco’s Modified Eagle Medium (DMEM), High Glucose w/o Phenol Red: 1X Liquid
  • Glucose4500 mg/L (4.5 g/L, High Glucose)
  • Formulation[+] L-Glutamine, [+] Sodium Bicarbonate, [+] Calcium, [+] Magnesium, [+] High Glucose (4500 mg/L), [+] Sodium Pyruvate | [-] Phenol Red
  • AppearancePale yellow to colorless, clear solution
  • pH (USP <791>)7.4
  • Osmolality (USP <785>)310–350 mOsm/kg H2O
  • Endotoxin (USP <85>)< 0.05 EU/mL
  • Sterility (USP <71>)No growth / 14 days
  • Filtration0.1 µm ×2 + 0.04 µm ×2 (Quadruple-stage)
  • Storage2–8°C, protected from light
  • Shelf Life12 months from date of manufacture, unopened
ISO 13485:2016 USP <85> <785> <788> RUO
Why FluxMPS™

Engineered where standard media fails

Conventional 0.22 µm–filtered DMEM passes mycoplasma-sized organisms, subvisible particulates, and cellular debris that clog microfluidic channels and interfere with sensor performance. FluxMPS™ High Glucose addresses these failure modes through quadruple-stage filtration while delivering 4.5 g/L glucose for energy-demanding cell types and complex tissue models.

filter_alt

Microchannel-safe purity

0.04 µm final filtration; USP <788> Method 1 particulate compliance supports safe perfusion in chip geometries, including sub-100 µm channels.

bolt

High-energy cell support

4.5 g/L glucose (4× vs low-glucose DMEM) sustains primary neurons, cardiomyocytes, cancer lines, and other aerobically active cells in prolonged perfusion.

water_drop

Ultrapure-grade water

Ultrapure Type 1 water (18.2 MΩ·cm, ASTM Type I / ISO 3696) with low trace-metal and organic-carbon (TOC) content, supporting sensitive electrophysiology and biosensor assays.

visibility

Low background for imaging

Ultra-low particulate baseline with no phenol red interference supports confocal microscopy and biosensor imaging platforms.

science

Rich, stable nutrient profile

32 ingredients verified per lot; 4× BME amino acid/vitamin concentration; micro-batch production with full traceability.

tune

Customization on demand

pH, glucose, salts, HEPES, and nutrients adjustable. Contact support@diagnocine.com.

Purity Architecture

Quadruple-stage filtration system

Four serial filtration passes — two prefilter-plus-final-filter pairs — reach a 0.04 µm final cut-off, removing sub-visible particulates and mycoplasma-sized organisms that pass through conventional single-stage 0.22 µm filtration.

  1. 1

    0.1 µm Prefiltration I

    Removes large aggregates, cell debris, and protein aggregates; protects the first 0.04 µm final filter cartridge.

  2. 2

    0.04 µm Final filtration I

    First 0.04 µm pass; retains sub-micron particulates and mycoplasma-sized organisms (0.2–0.3 µm) that pass a conventional 0.22 µm filter.

  3. 3

    0.1 µm Prefiltration II

    Second dedicated prefilter, protecting the second 0.04 µm final filter cartridge.

  4. 4

    0.04 µm Final filtration II — Polish

    Ultimate polishing filter; aseptic fill and finish in an ISO Class 5 (Class 100) environment.

Performance vs. conventional media

FluxMPS™ DCP-DMEM-R1X is processed through a quadruple-stage train (0.1 µm ×2 + 0.04 µm ×2) reaching a 0.04 µm final cut-off — five times finer than the 0.22 µm membranes used for conventional sterile filtration.

5.5×
Finer final pore size (0.04 µm) than conventional 0.22 µm sterile filtration
4
Sequential filtration passes (0.1 µm ×2 + 0.04 µm ×2)
Sterility & Mycoplasma: No growth after 14-day incubation (USP <71>). Mycoplasma risk is mitigated by 0.1 µm mycoplasma-retentive filtration (not tested per lot).
Grade: This product is Microfluidics Suitable, filtered to a 0.04 µm final cut-off. It is not an MPS Grade product — that designation is reserved for the 0.01 µm ultra nano-filtered line, which adds 0.02 µm and 0.01 µm stages after the 0.04 µm polish. For applications requiring the 0.01 µm cut-off, contact support@diagnocine.com.
FluxMPS™ DCP-DMEM-R1X Dulbecco's Modified Eagle Medium (DMEM), High Glucose w/o Phenol Red: 1X Liquid ? Quadruple-stage filtration system: 0.1 micron Prefiltration I, 0.04 micron Final filtration I, 0.1 micron Prefiltration II, 0.04 micron Final filtration II Polish ? Microfluidics Suitable DMEM High Glucose for organ-on-a-chip | Diagnocine
Figure 1. FluxMPS™ Quadruple-stage filtration system (0.1 µm ×2 + 0.04 µm ×2) reaching a 0.04 µm final cut-off.
© Diagnocine® — DCP-DMEM-R1X
Applications

Designed for next-generation cell models

FluxMPS™ DCP-DMEM-R1X supports demanding platforms from single-channel microfluidic chips to multi-organ body-on-a-chip systems. High glucose (4.5 g/L) makes it particularly suited to energy-intensive cell types and aerobically active cultures.

Automated Bioreactors & Robotics

Next-Generation System Uptime

An optional 0.01 µm (10 nm) MPS Grade ultra nano-filtered variant is available on request for automated bioreactor perfusion and robotic liquid handlers requiring the finer cut-off.

  • Total Particulate Exclusion: 10 nm filtration removes nanoparticulate aggregates
  • Valve & Sensor Protection: Reduces micro-fouling of solenoid valves and optical sensors
  • Extended Perfusion Stability: Consistent high-glucose delivery over weeks-long culture

Inquiry Required: Contact support@diagnocine.com for the 0.01 µm MPS Grade variant.

Microfluidics

Organ-on-a-Chip & MPS

Ultra-clean 0.04 µm–filtered media helps prevent microchannel clogging in complex multi-organ chip architectures.

OoCToCBoCLoCMPS
Cancer Biology

Warburg Effect & Cancer Models

High glucose (4.5 g/L) supports aerobic glycolysis phenotyping in cancer cell lines requiring elevated energy substrates.

MCF-7MDA-MB-231HeLaA549
Neuroscience

Primary Neurons & Brain-on-Chip

High glucose supports the metabolic demands of primary neurons and iPSC-derived neuronal networks in microfluidic perfusion.

iPSC-NeuronsPrimary neuronsBrain-on-chip
Cardiac Biology

Cardiomyocyte & Heart-on-Chip

High-glucose DMEM is widely used for iPSC-derived cardiomyocyte maturation and heart-on-chip functional assays.

iPSC-CMHeart-on-chipTEER
Metabolomics

Metabolic Flux Analysis

Defined high-glucose formulation for ¹³C isotope tracing and NMR-based glycolysis/OXPHOS profiling. Not compatible with Agilent Seahorse XF assays, which require bicarbonate-free, phenol red-free medium.

¹³C tracingNMR metabolomics
Live-Cell Imaging

Microscopy & Optical Sensing

Ultra-low particulate baseline and phenol red-free formulation support confocal microscopy and biosensor imaging platforms.

ConfocalBiosensorsTEER
Technical Specifications

Analytical release specifications

Every lot released against the full specification matrix. CoA: support@diagnocine.com.

Physical & Chemical Parameters
Parameter Specification
Formulation [+] L-Glutamine, [+] Sodium Bicarbonate, [+] Calcium, [+] Magnesium, [+] High Glucose (4500 mg/L), [+] Sodium Pyruvate | [-] Phenol Red
Appearance Pale yellow to colorless, clear solution
Glucose 4500 mg/L (4.5 g/L, High Glucose)
pH USP <791> 7.4
Osmolality USP <785> 310–350 mOsm/kg H2O
Total ingredients 32
Sterility, Purity & Safety Parameters
Parameter Specification
Endotoxin USP <85> BET < 0.05 EU/mL
Sterility USP <71> No growth / 14 days
Mycoplasma 0.1 µm mycoplasma-retentive filtration (not tested per lot)
Particulate ≥10 µm USP <788> Method 1 NMT 25/mL
Particulate ≥25 µm USP <788> Method 1 NMT 3/mL
Water purity Type 1, 18.2 MΩ·cm (ASTM Type I / ISO 3696)
Manufacturing std. ISO 13485:2016
Fill environment ISO Class 5 (Class 100)
Storage, Handling & Logistics
Parameter Specification
Storage temperature 2–8°C, protected from light
Freeze-thaw Do not freeze
Shelf life 12 months from date of manufacture, unopened
Shipping condition Cold pack
CO₂ requirement Approximately 10% CO₂ (bicarbonate-buffered; 3700 mg/L NaHCO3 requires ~10% CO₂ atmosphere to maintain pH 7.4)
Available pack sizes 500 mL, 1000 mL
Raw Materials & Regulatory Traceability
Parameter Specification
Raw material grade Reagent / cell culture grade
Traceability Full lot traceability per ISO 13485
Manufacturing QMS ISO ISO 13485:2016 certified
UNSPSC 41116155 — Molecular biology and cell culture growth media (UNv260801)
Regulatory alignment 21 CFR Part 820 (QMSR) aligned
Production method Micro-batch, per-lot QC release
Intended use Research Use Only (RUO)
Formulation

Full composition (mg/L)

DMEM High Glucose is a modification of Basal Medium Eagle (BME) with 4× BME amino acid and vitamin concentrations, plus glycine, serine, and ferric nitrate. 32 ingredients verified per lot with CAS numbers for raw-material traceability.

Component CAS Number mg/L
INORGANIC SALTS
Calcium chloride dihydrate 10035-04-8 265.000
Ferric nitrate nonahydrate 7782-61-8 0.100
Magnesium sulfate anhydrous 7487-88-9 97.720
Potassium chloride 7447-40-7 400.000
Sodium bicarbonate 144-55-8 3700.000
Sodium chloride 7647-14-5 6400.000
Sodium dihydrogen phosphate anhydrous 7558-80-7 109.000
Component CAS Number mg/L
AMINO ACIDS
Glycine 56-40-6 30.000
L-Arginine hydrochloride 1119-34-2 84.000
L-Cystine dihydrochloride 30925-07-6 62.570
L-Glutamine 56-85-9 584.000
L-Histidine hydrochloride monohydrate 5934-29-2 42.000
L-Isoleucine 73-32-5 105.000
L-Leucine 61-90-5 105.000
L-Lysine hydrochloride 657-27-2 146.000
L-Methionine 63-68-3 30.000
L-Phenylalanine 63-91-2 66.000
L-Serine 56-45-1 42.000
L-Threonine 72-19-5 95.000
L-Tryptophan 73-22-3 16.000
L-Tyrosine Disodium Salt dihydrate 69847-15-0 103.790
L-Valine 72-18-4 94.000
Component CAS Number mg/L
VITAMINS
Choline chloride 67-48-1 4.000
D-Ca-Pantothenate 137-08-6 4.000
Folic acid 59-30-3 4.000
Nicotinamide 98-92-0 4.000
Pyridoxal hydrochloride 65-22-5 4.000
Riboflavin 83-88-5 0.400
Thiamine hydrochloride 67-03-8 4.000
i-Inositol 87-89-8 7.200
OTHERS
D-Glucose 50-99-7 4500.000
Sodium pyruvate 113-24-6 110.000
Custom formulation: Contact support@diagnocine.com for DCP-DMEM-R1X custom specifications — pH, glucose, salts, HEPES, or nutrient modifications.
Quality Assurance

Manufacturing & compliance

Every FluxMPS™ product is manufactured and released under a multi-layer quality system spanning raw materials, in-process controls, and final-product testing.

verified

ISO 13485:2016 Quality Management

Manufactured under an ISO 13485:2016-certified quality management system. Final QA and testing at Diagnocine R&D Center, Totowa, NJ, USA.

water_drop

Ultrapure Type 1 Water

18.2 MΩ·cm resistivity (ASTM Type I / ISO 3696) with low trace-metal and organic-carbon (TOC) content.

biotech

ISO Class 5 Fill & Finish

Aseptic fill in validated ISO Class 5 (Class 100) laminar-flow workstations, supporting container-closure integrity.

assignment

Micro-Batch Precision

Small-batch production with full per-lot traceability; a Certificate of Analysis is issued for every batch — no blending, no averaged QC results.

Endotoxin — USP <85> BET

LAL assay; release specification < 0.05 EU/mL per batch.

Particulate — USP <788> Method 1

Light obscuration: ≤25/mL (≥10 µm), ≤3/mL (≥25 µm).

Osmolality — USP <785>

Freezing-point osmometry. Target: 310–350 mOsm/kg H2O.

Documentation & CoA

Full CoA with raw-material traceability available for every batch on request.

Batch-level quality control. Endotoxin is controlled per manufacturing batch rather than per unit. Every batch is tested before release and must meet the release specification:
  • Endotoxin — LAL assay, USP <85> Bacterial Endotoxins Test; assay sensitivity 0.005 EU/mL; release specification < 0.05 EU/mL
  • pH, osmolality, conductivity, appearance and clarity
  • Sterility
A Certificate of Analysis is available on request at support@diagnocine.com.
Product Comparison

How DCP-DMEM-R1X compares

FluxMPS™ DCP-DMEM-R1X vs. conventional 0.22 µm–filtered DMEM High Glucose formulations.

Parameter DCP-DMEM-R1X (FluxMPS™) Conventional DMEM HG
(0.22 µm filtered)
Standard Alt. DMEM HG
(0.22 µm filtered)
Grade Microfluidics Suitable Standard research grade Standard research grade
High Glucose DMEM without Phenol Red — removes phenol red’s autofluorescence signal (520–560 nm) and estrogen-receptor agonist interference check_circle Yes cancel No cancel No
Final filtration pore size 0.04 µm 0.22 µm 0.22 µm
Number of filtration stages 4 (Quadruple) 1 1
Mycoplasma barrier filtration check_circle Yes (0.1 µm mycoplasma-retentive) cancel No cancel No
Endotoxin (release specification) FluxMPS™ — < 0.05 EU/mL Corning classical liquid media — < 0.25 EU/mL
Sigma-Aldrich DMEM complete medium — ≤ 2 EU/mL
Gibco classical DMEM — Not specified (recorded per lot)
USP <788> Method 1 particulate tested check_circle Yes cancel No cancel No
Water quality Type 1, 18.2 MΩ·cm Purified water Purified water
Manufacturing QMS ISO 13485:2016 ISO 9001 or none ISO 9001 or none
Microfluidic channel compatibility check_circle Microfluidics Suitable cancel Risk of clogging cancel Risk of clogging
Custom formulation check_circle Available cancel Fixed cancel Fixed

Comparison figures from published supplier specifications, accessed 2026-09-02. Suppliers that publish no numeric endotoxin specification are shown as “Not specified”.

FAQ

Frequently asked questions

Common questions about FluxMPS™ DCP-DMEM-R1X DMEM High Glucose.

Yes. DCP-DMEM-R1X is Microfluidics Suitable, processed through a quadruple-stage filtration system reaching a 0.04 µm final cut-off, for MPS, OoC, ToC, and LoC platforms. High glucose (4.5 g/L) makes it well suited to energy-demanding cell types including primary neurons, cardiomyocytes, and cancer cell lines in long-duration chip perfusion.
FluxMPS™ uses four sequential filters — 0.1 µm prefiltration I, 0.04 µm final filtration I, 0.1 µm prefiltration II, and 0.04 µm final filtration II — resulting in a 0.04 µm final cut-off, five times finer than the 0.22 µm membranes used in conventional single-stage filtration.
Phenol red is a weak estrogen-receptor agonist that can confound hormone-sensitive assays (ER+ breast cancer, endocrine models) and produces its own autofluorescence at 520–560 nm. Removing it eliminates that specific signal, improving clarity for confocal microscopy, TEER sensors, and biosensor arrays on chip.
This formulation is bicarbonate-buffered (3700 mg/L NaHCO3) and requires an atmosphere of approximately 10% CO₂ to maintain pH 7.4. For lower CO₂ or ambient incubation, contact support@diagnocine.com about a HEPES-buffered variant.
Yes. Add FBS (typically 5–10%), serum-free supplements, growth factors, antibiotics, or custom nutrients as required. When filtering serum-containing additions, use a 0.2 µm low-protein-binding PES or PVDF filter — never 0.04 µm, which strips serum of essential lipoproteins. Contact support@diagnocine.com for custom co-formulation.
Each batch is tested by LAL assay (USP <85>) before release. FluxMPS™ DCP-DMEM-R1X must meet a release specification of < 0.05 EU/mL; assay sensitivity is 0.005 EU/mL. A Certificate of Analysis with the batch’s result is available on request.
Yes. A full CoA per batch covers: appearance, pH (USP <791>), osmolality (USP <785>), sterility (USP <71>), endotoxin (USP <85>), mycoplasma (filtration statement), particulate count (USP <788> Method 1), and raw-material traceability. Request at support@diagnocine.com.
Scientific References

Supporting literature

Key peer-reviewed publications supporting Microfluidics Suitable, ultra-filtered DMEM High Glucose in organ-on-a-chip and metabolic research.

  1. Huh D, et al. Reconstituting organ-level lung functions on a chip. Science. 2010;328:1662–1668. doi:10.1126/science.1188302
  2. Bhatia SN, Ingber DE. Microfluidic organs-on-chips. Nat Biotechnol. 2014;32:760–772. doi:10.1038/nbt.2989
  3. Warburg O. On the origin of cancer cells. Science. 1956;123:309–314. doi:10.1126/science.123.3191.309
  4. Novak R, et al. Robotic fluidic coupling and interrogation of multiple vascularized organ chips. Nat Biomed Eng. 2020;4:407–420. doi:10.1038/s41551-019-0497-x
  5. Katt ME, et al. In vitro tumor models: advantages, disadvantages, variables, and selecting the right platform. Front Bioeng Biotechnol. 2016;4:12. doi:10.3389/fbioe.2016.00012
  6. Jang KJ, et al. Human kidney proximal tubule-on-a-chip for drug transport and nephrotoxicity assessment. Integr Biol. 2013;5:1119–1129. doi:10.1039/c3ib40049b
  7. Schimek K, et al. Integrating biological vasculature into a multi-organ-chip microsystem. Lab Chip. 2013;13:3588–3598. doi:10.1039/c3lc50217a
  8. Luni C, et al. High-efficiency cellular reprogramming with microfluidics. Nat Methods. 2016;13:446–452. doi:10.1038/nmeth.3832
  9. Sung JH, et al. Microfabricated mammalian organ systems and their integration into models of whole animals and humans. Lab Chip. 2013;13:1201–1212. doi:10.1039/c3lc41017j

Satisfaction
Quality Rating
Value Rating
Style Rating
X